The single-run resolving power of current 10 μm id porous-layer open-tubular (PLOT) columns has been optimized. The columns studied had a poly(styrene-co-divinylbenzene) porous layer (~0.75 μm thickness). In contrast to many previous studies that have employed complex plumbing or compromising set-ups, SPE-PLOT-LC-MS was assembled without the use of additional hardware/noncommercial parts, additional valves or sample splitting. A comprehensive study of various flow rates, gradient times, and column length combinations was undertaken. Maximum resolution for <400 bar was achieved using a 40 nL/min flow rate, a 400 min gradient and an 8 m long column. We obtained a 2.3-fold increase in peak capacity compared to previous PLOT studies (950 versus previously obtained 400, when using peak width = 2σ definition). Our system also meets or surpasses peak capacities obtained in recent reports using nano-ultra-performance LC conditions or long silica monolith nanocolumns. Nearly 500 proteins (1958 peptides) could be identified in just one single injection of an extract corresponding to 1000 BxPC3 beta catenin (-/-) cells, and ~1200 and 2500 proteins in extracts of 10,000 and 100,000 cells, respectively, allowing detection of central members and regulators of the Wnt signaling pathway.
Reliable, sensitive and automatable analytical methodology is of great value in e.g. cancer diagnostics. In this context, an on-line system for enzymatic cleavage of proteins, subsequent peptide separation by liquid chromatography (LC) with mass spectrometric detection has been developed using “sub-chip” columns (10–20 μm inner diameter, ID). The system could detect attomole amounts of isolated cancer biomarker progastrin-releasing peptide (ProGRP), in a more automatable fashion compared to previous methods. The workflow combines protein digestion using an 20 μm ID immobilized trypsin reactor with a polymeric layer of 2-hydroxyethyl methacrylate-vinyl azlactone (HEMA-VDM), desalting on a polystyrene-divinylbenzene (PS-DVB) monolithic trap column, and subsequent separation of resulting peptides on a 10 μm ID (PS-DVB) porous layer open tubular (PLOT) column. The high resolution of the PLOT columns was maintained in the on-line system, resulting in narrow chromatographic peaks of 3–5 seconds. The trypsin reactors provided repeatable performance and were compatible with long-term storage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.