2013
DOI: 10.1002/jssc.201300499
|View full text |Cite
|
Sign up to set email alerts
|

Separation optimization of long porous‐layer open‐tubular columns for nano‐LCMS of limited proteomic samples

Abstract: The single-run resolving power of current 10 μm id porous-layer open-tubular (PLOT) columns has been optimized. The columns studied had a poly(styrene-co-divinylbenzene) porous layer (~0.75 μm thickness). In contrast to many previous studies that have employed complex plumbing or compromising set-ups, SPE-PLOT-LC-MS was assembled without the use of additional hardware/noncommercial parts, additional valves or sample splitting. A comprehensive study of various flow rates, gradient times, and column length combi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
41
0
4

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(45 citation statements)
references
References 49 publications
0
41
0
4
Order By: Relevance
“…Rogeberg et al . compared the performance of silica-based and polymer-based monolithic columns and discovered a peak capacity of 950 from a 10 μm × 8 m PS-DVB PLOT column, which meets or surpasses peak capacities of previously reported using packed nanoLC or long silica monolithic columns [45]. With the PLOT column, about 500 and 1200 proteins were identified from an extract corresponding to 1000 and 10,000 cells, respectively [45].…”
Section: Lc or Ce For Nanoproteomicsmentioning
confidence: 92%
“…Rogeberg et al . compared the performance of silica-based and polymer-based monolithic columns and discovered a peak capacity of 950 from a 10 μm × 8 m PS-DVB PLOT column, which meets or surpasses peak capacities of previously reported using packed nanoLC or long silica monolithic columns [45]. With the PLOT column, about 500 and 1200 proteins were identified from an extract corresponding to 1000 and 10,000 cells, respectively [45].…”
Section: Lc or Ce For Nanoproteomicsmentioning
confidence: 92%
“…However, substantial effort is still required in column manufacture to significantly improve chromatographic separation and miniaturization [8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…Nos últimos anos, as colunas OT do tipo PLOT emergiram como ferramentas promissoras em cromatografia líquida (33,92). OT têm um consumo extremamente baixo de solventes, e permite maior sensibilidade ao usar espectrometria de massas por ionização por electrospray (ESI-MS) (93).…”
Section: Colunas Plotunclassified
“…OT têm um consumo extremamente baixo de solventes, e permite maior sensibilidade ao usar espectrometria de massas por ionização por electrospray (ESI-MS) (93). OT colunas têm recebido atenção devido à sua bem sucedida cromatografia de compostos de elevada massa molecular, tais como proteínas e peptídeos com alta capacidade de pico em sistemas de alta sensibilidade nano-LC tandem MS (MS / MS) (32,92,94,95,96,97). No entanto, as colunas do tipo OT estão associadas a uma fraca retenção e é praticamente não favorável para a análise de moléculas pequenas, o que está muito mais associado a colunas maiores e de alta capacidade.…”
Section: Colunas Plotunclassified
See 1 more Smart Citation