Rapid and cost-effective analysis of histamine, in food, environmental, and diagnostics research has been of interest recently. However, for certain applications, the already-existing biological receptor-based sensing methods have usage limits in terms of stability and costs. As a result, robust and cost-effective imprinted polymeric receptors can be the best alternative. In the present work, molecularly-imprinted polymers (MIPs) for histamine were synthesized using methacrylic acid in chloroform and acetonitrile as two different porogens. The binding affinity of the MIPs with histamine was evaluated in aqueous media. MIPs synthesized in chloroform displayed better imprinting properties for histamine. We demonstrate here histamine MIPs incorporated into a carbon paste (CP) electrode as a MIP-CP electrode sensor platforms for detection of histamine. This simple sensor format allows accurate determination of histamine in the sub-nanomolar range using an electrochemical method. The sensor exhibited two distinct linear response ranges of 1 × 10−10–7 × 10−9 M and 7 × 10−9–4 × 10−7 M. The detection limit of the sensor was calculated equal to 7.4 × 10−11 M. The specificity of the proposed electrode for histamine is demonstrated by using the analogous molecules and other neurotransmitters such as serotonin, dopamine, etc. The MIP sensor was investigated with success on spiked serum samples. The easy preparation, simple procedure, and low production cost make the MIP sensor attractive for selective and sensitive detection of analytes, even in less-equipped laboratories with minimal training.
Herein, a carbon paste electrode, concurrently incorporated with ferrocene and a molecularly imprinted polymer nanomaterial (Fc-MIP-CP electrode), is introduced as an innovative sensing platform for the detection of thiamine.
Electrochemical determination of melatonin in the presence of tryptophan is a challenge because of the coincidence of voltammetric signals of these compounds when executing a voltammetric technique. The new method for selective determination of melatonin based on the square wave anodic stripping voltammetry determination of an electroactive product of melatonin was suggested here. This product is produced by previously applied positive pre‐potential to a carbon paste electrode, immersed in the test solution. By this means, the electrochemical signal of melatonin was separated effectively from that of tryptophan, making it possible to determine melatonin in the presence of a high concentration of tryptophan. The effect of important parameters on electrode performance was studied and optimized. The optimum response was obtained at pH=2 and utilizing the pre‐potential magnitude of +0.8 V, applied for 10 s. A linear relationship was found between peak current intensity and melatonin concentrations over the range of 5.00×10−7 to 8.00×10−5 mol L−1. A detection limit of 8.30×10−8 mol L−1 was calculated for the method (S/N=3). The selectivity of the method was considerably high, because of the independence of melatonin signal to the presence of higher amounts of some potentially interfering agents such as ascorbic acid, tryptophane glucose, etc. As an analytical application, the proposed sensor was used for the determination of melatonin in pharmaceutical and food samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.