All rights reserved. No part of this pUblication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photo-copying, microfilming, recording, or otherwise, without the prior written permission of the publisher, with the exception of any material supplied specifically for the purpose of being entered and executed on a computer system, for exclusive use by the purchaser ofthe work.
A number of experimental and clinical studies have documented the risk potential of interference with implanted pacemakers by various types of cellular phones. Radiofrequency susceptibility of external medical equipment has also been reported in experimental studies. The purpose of this experimental study was to evaluate electromagnetic interference of external pacemakers by walkie-talkies and digital cellular telephones. External bipolar pacing was monitored using a digital oscilloscope to record pacemaker pulses and electromagnetic interference separately. Tests with the walkie-talkie, Private Mobile Radio (PMR) (160 MHz, 2.5 W) were conducted during the calling phase. Tests with the cellular phones, global system for mobile communications (GSM) (900 MHz, 2 W) and Digital Cellular System (DCS) (1,800 MHz, 1 W) were conducted in the test mode. Nine widely used external pacemakers from four manufacturers were tested. Various disturbances including pacing inhibition and asynchronous pacing were observed in eight pacemakers by the PMR, in four by the GSM phone, and in two by the DCS phone. The maximum distance that interference persisted ranged from 10-200 cm. This experimental study shows a potential risk of interference of external pacemakers by walkie-talkies and cellular digital phones. Appropriate warnings should be issued against the potentially serious risks of using communication devices in the vicinity of acutely ill patients treated with temporary transvenous cardiac pacemakers.
Abstract.We prove the existence and uniqueness of the weak solution for a quasistatic thermoviscoelastic problem which describes bilateral frictional contact between a deformable body and a moving rigid foundation. The model consists of the heat equation for the temperature, the elliptic viscoelasticity system for the displacements, the SJK-Coulomb law of friction and frictional heat generation condition. The proof is accomplished in two steps. First, the existence of solutions for a regularized problem is established and a priori estimates obtained. Then the limit function, which is the weak solution of the original problem, is shown to be the unique fixed point of the solution operator when the friction coefficient is small.
International audienceWe study a class of dynamic thermal sub-differential contact problems with friction, for long memory visco-elastic materials, which can be put into a general model of system defined by a second order evolution inequality, coupled with a first order evolution equation. We present and establish an existence and uniqueness result, by using general results on first order evolution inequality, with monotone operators and fixed point methods
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.