Background
Liver resection and thermoablation are the mainstay of the surgical management of colorectal liver metastases (CRLM). The main limitation of thermoablation is the “heat‐sink” effect for nodules next to large vessels. Herein, we report the preliminary results of microwave ablation (MWA) with associated Pringle maneuver to overcome this flaw.
Methods
From November 2017, we performed intraoperative MWA with Pringle maneuver for nodules ≤3 cm with immediate proximity to large vessels (distance ≤ 5 mm, diameter ≥ 3 mm). We collected characteristics of nodules, surgical procedures and postoperative morbidity. Diameter of the ablation area, especially the ablative minimal margin, was calculated for each nodule. Recurrence was also evaluated.
Results
Nineteen patients underwent MWA with Pringle maneuver for 23 nodules. Nineteen (83%) ablated nodules were located in segments VI, VII and VIII, and one nodule was in segment I. Median size of nodules was 15 mm (10–21). No deaths occurred. Six patients (38%) experienced complications, among them only one was subsequent to the thermal ablation. Ablative minimal margin was ≥5 mm for 19 (83%) nodules. Margin was not sufficient for four nodules, among them only 2/23 cases (8.7%) of in situ recurrence occurred after 12 months of median follow‐up.
Conclusions
In this preliminary study, MWA with Pringle maneuver was associated with a low related morbidity rate and favorable oncological outcome, especially when the radiological minimal margin was sufficient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.