ObjectivesThe ability to determine human bone stiffness is of clinical relevance in many fields, including bone quality assessment and orthopaedic prosthesis design. Stiffness can be measured using compression testing, an experimental technique commonly used to test bone specimens in vitro. This systematic review aims to determine how best to perform compression testing of human bone.MethodsA keyword search of all English language articles up until December 2017 of compression testing of bone was undertaken in Medline, Embase, PubMed, and Scopus databases. Studies using bulk tissue, animal tissue, whole bone, or testing techniques other than compression testing were excluded.ResultsA total of 4712 abstracts were retrieved, with 177 papers included in the analysis; 20 studies directly analyzed the compression testing technique to improve the accuracy of testing. Several influencing factors should be considered when testing bone samples in compression. These include the method of data analysis, specimen storage, specimen preparation, testing configuration, and loading protocol.ConclusionCompression testing is a widely used technique for measuring the stiffness of bone but there is a great deal of inter-study variation in experimental techniques across the literature. Based on best evidence from the literature, suggestions for bone compression testing are made in this review, although further studies are needed to establish standardized bone testing techniques in order to increase the comparability and reliability of bone stiffness studies.Cite this article: S. Zhao, M. Arnold, S. Ma, R. L. Abel, J. P. Cobb, U. Hansen, O. Boughton. Standardizing compression testing for measuring the stiffness of human bone. Bone Joint Res 2018;7:524–538. DOI: 10.1302/2046-3758.78.BJR-2018-0025.R1.
ObjectivesBone material properties are a major determinant of bone health in older age, both in terms of fracture risk and implant fixation, in orthopaedics and dentistry. Bone is an anisotropic and hierarchical material so its measured material properties depend upon the scale of metric used. The scale used should reflect the clinical problem, whether it is fracture risk, a whole bone problem, or implant stability, at the millimetre-scale. Indentation, an engineering technique involving pressing a hard-tipped material into another material with a known force, may be able to assess bone stiffness at the millimetre-scale (the apparent elastic modulus). We aimed to investigate whether spherical-tip indentation could reliably measure the apparent elastic modulus of human cortical bone.Materials and methodsCortical bone samples were retrieved from the femoral necks of nineteen patients undergoing total hip replacement surgery (10 females, 9 males, mean age: 69 years). The samples underwent indentation using a 1.5 mm diameter, ruby, spherical indenter tip, with sixty indentations per patient sample, across six locations on the bone surfaces, with ten repeated indentations at each of the six locations. The samples then underwent mechanical compression testing. The repeatability of indentation measurements of elastic modulus was assessed using the co-efficient of repeatability and the correlation between the bone elastic modulus measured by indentation and compression testing was analysed by least-squares regression.ResultsIn total, 1140 indentations in total were performed. Indentation was found to be repeatable for indentations performed at the same locations on the bone samples with a mean co-efficient of repeatability of 0.4 GigaPascals (GPa), confidence interval (C.I): 0.33–0.42 GPa. There was variation in the indentation modulus results between different locations on the bone samples (mean co-efficient of repeatability: 3.1 GPa, C.I: 2.2–3.90 GPa). No clear correlation was observed between indentation and compression values of bone elastic modulus (r = 0.33, p = 0.17). The mean apparent elastic modulus obtained by spherical indentation was 9.9 GPa, the standard deviation for each indent cycle was 0.11 GPa, and the standard deviation between locations on the same sample was 1.01 GPa. The mean compression apparent elastic modulus was 4.42 GPa, standard deviation 1.02 GPa.DiscussionSpherical-tip indentation was found to be a repeatable test for measuring the elastic modulus of human cortical bone, demonstrated by a low co-efficient of repeatability in this study. It could not, however, reliably predict cortical bone elastic modulus determined by platens compression testing in this study. This may be due to indentation only probing mechanical properties at the micro-scale while platens compression testing assesses millimetre length-scale properties. Improvements to the testing technique, including the use of a larger diameter spherical indenter tip, may improve the measurement of bone stiffness at the millimetre scale...
ObjectivesMicroindentation has the potential to measure the stiffness of an individual patient’s bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness.MethodsA systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded.ResultsA total of 1094 abstracts were retrieved and 32 papers were included in the analysis, 20 of which used reference point indentation, and 12 of which used traditional depth-sensing indentation. There are several factors that must be considered when using microindentation, such as tip size, depth and method of analysis. Only two studies validated microindentation against traditional mechanical testing techniques. Both studies used reference point indentation (RPI), with one showing that RPI parameters correlate well with mechanical testing, but the other suggested that they do not.ConclusionMicroindentation has been used in various studies to assess bone stiffness, but only two studies with conflicting results compared microindentation with traditional mechanical testing techniques. Further research, including more studies comparing microindentation with other mechanical testing methods, is needed before microindentation can be used reliably to calculate cortical bone stiffness.Cite this article: M. Arnold, S. Zhao, S. Ma, F. Giuliani, U. Hansen, J. P. Cobb, R. L. Abel, O. Boughton. Microindentation – a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017;6:542–549. DOI: 10.1302/2046-3758.69.BJR-2016-0317.R2.
Background:Power tools are an integral part of orthopaedic surgery but have the capacity to cause iatrogenic injury. With this systematic review, we aimed to investigate the prevalence of iatrogenic injury due to the use of power tools in orthopaedic surgery and to discuss the current methods that can be used to reduce injury.Methods:We performed a systematic review of English-language studies related to power tools and iatrogenic injuries using a keyword search in MEDLINE, Embase, PubMed, and Scopus databases. Exclusion criteria included injuries related to cast-saw use, temperature-induced damage, and complications not clearly related to power-tool use.Results:A total of 3,694 abstracts were retrieved, and 88 studies were included in the final analysis. Few studies and individual case reports looked directly at the prevalence of injury due to power tools. These included 2 studies looking at the frequency of vascular injury during femoral fracture fixation (0.49% and 0.2%), 2 studies investigating the frequency of vertebral artery injury during spinal surgery (0.5% and 0.08%), and 4 studies investigating vascular injury during total joint arthroplasty (1 study involving 138 vascular injuries in 124 patients, 2 studies noting 0.13% and 0.1% incidence, and 1 questionnaire sent electronically to surgeons). There are multiple methods for preventing damage during power-tool use. These include the use of robotics and simulation, specific drill settings, and real-time feedback techniques such as spectroscopy and electromyography.Conclusions:Power tools have the potential to cause iatrogenic injury to surrounding structures during orthopaedic surgery. Fortunately, the published literature suggests that the frequency of iatrogenic injury using orthopaedic power tools is low. There are multiple technologies available to reduce damage using power tools. In high-risk operations, the use of advanced technologies to reduce the chance of iatrogenic injury should be considered.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Introduction Ankle instability in children due to soft tissue injury usually resolves after non-operative treatment. However, some children and adolescents with chronic instability require surgical treatment. A rarer cause of developing ankle instability is injury to the ligament complex in the presence of os subfibulare, an accessory bone inferior to the lateral malleolus. The aim of this study was to assess the results of operative management of chronic ankle instability in children with os subfibulare. Materials and methods 16 children with os subfibulare and chronic ankle instability who failed non-operative treatment were enrolled prospectively into the study. One child was lost to follow-up and excluded from analysis. The mean age at the time of the surgery was 14 years and 2 months (range 9.5–17 years). The mean follow-up time was 43.2 months (range 28–48 months). Surgical treatment in all cases involved removal of os subfibulare and a modified Broström-Gould lateral complex reconstruction with anchors. Ankle status was assessed before and after surgery with The 100 mm Visual Analogue Scale and Foot and Ankle Outcome Score questionnaire. Results The mean Foot and Ankle Outcome Score improved from 66.8 to 92.3 (p < 0.001). Pain level improved from 67.1 preoperatively to 12.7 (p < 0.001). All children reported improvement in their ankle stability. There was one case of scar hypersensitivity that improved during observation and one superficial wound infection that resolved with oral antibiotics. One child reported intermittent pain without symptoms of instability following another injury. Conclusions Ankle joint sprain with associated injury to os subfibulare complex can lead to chronic instability in children. If conservative management fails, then surgical treatment with modified Broström-Gould technique and excision of accessory bone is a safe and reliable method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.