Work in vitro has previously shown superior restoration of knee stability using a double-bundle anterior cruciate ligament (ACL) reconstruction compared with single bundles taken through the condyle or 'over the top'. This paper describes an animal study designed to compare the three ACL reconstructions in vivo, in order to collect data that could support the clinical use of a double-bundle reconstruction. The three methods were compared in three groups of eight sheep, the ovine ACL having a distinct double-bundle structure. Biomechanically matched polyester fibre implants were used, with 6 months in vivo. The three methods led to similar intra-articular fibrous tissue integration of the implants and no evidence of implant damage, and biomechanical testing found greater laxity than normal for all three groups. The double-bundle group, however, had more joint surface degeneration than the other groups. It was concluded that clinical use of the double-bundle reconstruction was not indicated by the results of this experiment, in view of the more complex surgery and lack of superior performance.
We excised the anterior cruciate ligament from the left stifle of 24 sheep and replaced it by a polyester fibre implant routed 'over the top' of the femoral condyle and fixed, using grommets and screws. All the joints were sound, and the animals moved normally until they were killed at six, 12 and 24 months after operation. We found that the implants were always covered by host tissue, which matured into bundles with a histological appearance similar to the natural ligament. The implants were joined to the bones by organised fibrous tissue and there was no anchorage loosening. There was no synovitis, but the operated joints showed progressive cartilage degeneration. The reconstructed joints became less stable immediately after operation, but regained normal stability as the neoligaments developed. The neoligaments lost strength with time, despite tissue ingrowth. The good functional, biomechanical, and histological results justify clinical trials of this type of implant.
Forty-six near-adult pigs (mean age 10 months, mean weight 156 kg) were anaesthetised for laparoscopy. After intramuscular azaperone (1.0 mg/kg) and ketamine (2.5 mg/kg), 14 of the pigs received intravenous etomidate (200 micrograms/kg) and midazolam (100 micrograms/kg) and 17 were given ketamine (2 mg/kg) and midazolam (100 micrograms/kg). The other 15 pigs were anaesthetised with pentobarbitone (15 to 20 mg/kg) without pre-anaesthetic medication. The duration and adequacy of anaesthesia, recovery rate, and seven physiological variables (ECG, heart rate, indirect arterial blood pressure, respiratory rate, minute volume, mean end-tidal carbon dioxide concentration and percentage oxygen saturation of haemoglobin) were compared. Repeated injections were needed in 29 of the 46 cases. Pentobarbitone was the least satisfactory drug because although the haemodynamic variables were greater, it caused more respiratory depression and a higher overall complication rate than the other methods. Apnoea occurred in two pigs, and was fatal in one, and positive pressure ventilation with oxygen was needed in three others. Intubation conditions were poorer and the times to standing, walking and rooting were longer in the pigs anaesthetised with pentobarbitone.
The minimum alveolar concentration (MAC) of halothane was determined in New Zealand White rabbits. Tracheal anaesthetic concentrations were measured using a Siemens Servo Gas Monitor. A stimulator was used to deliver precisely controlled mechanical stimuli for the determination of MAC. Movement of the rabbit's head was recorded using a force transducer attached to the teeth. Evidence is presented that for the determination of MAC a precise nociceptive threshold is preferable to the so-called supramaximal stimulus used in clinical anaesthesia and in determination of anaesthetic potency. We conclude that techniques for the determination of MAC which disregard either sensitization of sensory mechanisms by producing tissue inflammation or the possibility of nerve compression by severe mechanical stimuli are of questionable value. The use of the mechanical stimulator described, or a similar device, would help in the standardization of the determination of MAC in all species by facilitating the application of a force of controlled amplitude, duration and velocity, thereby removing some of the variables which confound comparative studies of MAC.
The frequency of gastro-oesophageal reflux (GOR) in sheep anaesthetized with halothane was reduced by withholding food and water for 24 hours. The total reflux volume increased. The effect of body position on GOR was studied by inclining the operating table at angles to the horizontal and positioning the head up or down on sand bags. The operative positions investigated were: right and left lateral recumbency with head down, dorsal recumbency with head down and right lateral recumbency with head up. Least GOR occurred when the sheep was in right lateral recumbency with a head up tilt and the body inclined at 20 degrees from the horizontal. A cuffed oesophageal drainage tube increased the incidence of GOR but prevented the chances of the aspiration of rumen material.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.