The experimental alloys are suitable options for dental implant manufacturing, particularly the binary system, which showed a better combination of mechanical and electrochemical properties without the presence of toxic elements.
The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; a=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.
A modular synthetic approach was developed in which variation of the triplets of building blocks used enabled systematic variation of the macrocyclic scaffolds prepared. The approach was demonstrated in the synthesis of 17 diverse natural product‐like macrocyclic scaffolds of varied (12–20‐membered) ring size. The biological relevance of the chemical space explored was demonstrated through the discovery of a series of macrocycles with significant antimycobacterial activity.
The purpose of this study was to compare the compressive strengths and compressive fatigue limits of three posterior composite resins (Filtek P-60, Surefil and Prodigy Condensable) and a universal restorative composite (Z-100). Cylindrical specimens (8 mm in length x 4 mm in diameter) were used. The dynamic test was performed using the staircase method, and the ratio between compressive fatigue limit and compressive resistance was also calculated (n = 15). The compressive strength and compressive fatigue limit data were analyzed by Anova and Tukeys test. The Z-100 composite demonstrated higher compression strength (307.20 MPa) than Surefil (266.93 MPa) and Prodigy Condensable (222.08 MPa). The resistance of Filtek P-60 (270.44 MPa) was similar to the resistances of Z-100 and Surefil, while Prodigy Condensable presented the lowest compressive strength. In the compressive fatigue limit tests, Filtek P-60 demonstrated a higher value (184.20 MPa) than Prodigy Condensable (155.50 MPa). Surefil (165.74 MPa) and Z-100 (161.22 MPa) presented limits similar to those of Filtek P-60 and Prodigy Condensable. The compressive fatigue limit/compressive strength ratio was 70.01% for Prodigy Condensable, 68.11% for Filtek P-60, 62.09% for Surefil and 52.48% for Z-100. It was concluded that the Z-100 universal composite was more sensitive to the dynamic test than the high viscosity materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.