This work quantifies the impact of using sCO2-mixtures (s-CO2/He, s-CO2/Kr, s-CO2/H2S, s-CO2/CH4, s-CO2/C2H6, s-CO2/C3H8, s-CO2/C4H8, s-CO2/C4H10, s-CO2/C5H10, s-CO2/C5H12 and s-CO2/C6H6) as the working fluid in the supercritical CO2 recompression Brayton cycle coupled with line-focusing solar power plants (with parabolic trough collectors (PTC) or linear Fresnel (LF)). Design parameters assessed are the solar plant performance at the design point, heat exchange dimensions, solar field aperture area, and cost variations in relation with admixtures mole fraction. The adopted methodology for the plant performance calculation is setting a constant heat recuperator total conductance (UAtotal). The main conclusion of this work is that the power cycle thermodynamic efficiency improves by about 3–4%, on a scale comparable to increasing the turbine inlet temperature when the cycle utilizes the mentioned sCO2-mixtures as the working fluid. On one hand, the substances He, Kr, CH4, and C2H6 reduce the critical temperature to approximately 273.15 K; in this scenario, the thermal efficiency is improved from 49% to 53% with pure s-CO2. This solution is very suitable for concentrated solar power plants coupled to s-CO2 Brayton power cycles (CSP-sCO2) with night sky cooling. On the other hand, when adopting an air-cooled heat exchanger (dry-cooling) as the ultimate heat sink, the critical temperatures studied at compressor inlet are from 318.15 K to 333.15 K, for this scenario other substances (C3H8, C4H8, C4H10, C5H10, C5H12 and C6H6) were analyzed. Thermodynamic results confirmed that the Brayton cycle efficiency also increased by about 3–4%. Since the ambient temperature variation plays an important role in solar power plants with dry-cooling systems, a CIT sensitivity analysis was also conducted, which constitutes the first approach to defining the optimum working fluid mixture for a given operating condition.
Most of the deployed commercial line-focusing solar power plants with Parabolic Troughs (PTC) or Linear Fresnel (LF) solar collectors and Rankine power cycles use a Single Loop Solar Field (SF), Configuration 1 illustrated in Fig. 2, with synthetic oil as Heat Transfer Fluid (HTF) [1,2]. However, thermal oils maximum operating temperature should be below ~400ºC for assuring no oil degradation, hence limiting the power cycle gross efficiency up to ~38%. For overcoming this limitation Molten Salts (MS) as HTF in linear solar collectors (PTC and LF) were recently experimented in pilot facilities [3,4]. Direct MS main drawbacks are the equipments and components material corrosion and the salts freezing temperature, requiring heat tracing to avoid any sald solidification, hence increasing the Solar Field (SF) capital investment cost and parasitic energy looses. Concentrated Solar Power plants (CSP) with Dual Loop SF are being studied since 2012 [5] for gaining the synergies between thermal oils and MS properties. In the Dual Loop SF the HTF in the primary loop is thermal oil (Dowtherm A) [6] for heating the Balance Of Plant (BOP) working fluid from ~300ºC up to ~400ºC, and a secondary loop with Solar Salt (60% NaNO 3 , 40% KNO 3 ) as HTF, for boosting the working fluid temperature from ~400ºC up to 550ºC [7,8,9]. The CSP Dual Loop state of the art technology includes Rankine power cycles, the main innovation of this paper is the integration between Dual Loop SF and the supercritical Carbon Dioxide (s-CO 2 ) Brayton power cycles [10], see Configurations 2 and 3 illustrated in Fig. 3a, Fig 3b. A secondary innovation studied in this paper is the integration between thermal oil HTF (Dowtherm A) in linear solar collectors, a widely validated and mature technology, with the s-CO 2 Brayton power cycles. This technical solution is very cost competitive with carbon steel receiver pipes, low SF operating pressure, and no requiring any heat tracing.Two main conclusions are deducted from this researching study. Firstly we demonstrated the higher gross plant efficiency ~44.4%, with 550ºC Turbine Inlet Temperature (TIT), provided by the Dual Loop with the Simple recuperated s-CO2 Brayton cycle with reheating, in comparison with 41.8% obtained from the Dual Loop SF and subcritical water Rankine power cycle. And finally the second conclusion obtained is the selection of the most cost competitive plant configuration with a Single loop SF with Dowtherma A and a s-CO2 Brayton power cycle due to the receiver material low cost and no heat tracing for the thermal oil.
In this work, an evaluation and quantification of the impact of using mixtures based on supercritical carbon dioxide “s-CO2” (s-CO2/COS, s-CO2/H2S, s-CO2/NH3, s-CO2/SO2) are made as a working fluid in simple and complex recompression Brayton s-CO2 power cycle configurations that have pressure drops in their components. These cycles are coupled with a solar thermal plant with parabolic-trough collector (PTC) technology. The methodology used in the calculation performance is to establish values of the heat recuperator total conductance (UAtotal) between 5 and 25 MW/K. The main conclusion of this work is that the cycle’s efficiency has improved due to using s-CO2 mixtures as working fluid; this is significant compared to the results obtained using the standard fluid (pure s-CO2). Furthermore, a techno-economic analysis is carried out that compares each configuration’s costs using pure s-CO2 and a mixture of s-CO2/COS with a molar fraction (70/30), respectively, as working fluid where relevant results are obtained. These results show that the best configuration in terms of thermal efficiency and cost is the RCC-RH for pure sCO2 with values of 41.25% and 2811 $/kWe, while for the mixture sCO2/COS, the RCC-2RH configuration with values of 45.05% and 2621 $/kWe is optimal. Using the mixture costs 6.75% less than if it is used the standard fluid (s-CO2).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.