Objectives To compare the value of zero echo time (ZTE) and gradient echo “black bone” (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. Materials and methods Between May 2019 and January 2021, 79 patients prospectively underwent clinically indicated 3-T MRI including ZTE and BB imaging. Additionally, all patients underwent a CT scan covering the SI joints within 12 months of the MRI examination. Two blinded readers performed bone assessment by grading each side of each SI joint qualitatively in terms of seven features (osteophytes, subchondral sclerosis, erosions, ankylosis, joint irregularity, joint widening, and gas in the SI joint) using a 4-point Likert scale (0 = no changes–3 = marked changes). Scores were compared between all three imaging modalities. Results Interreader agreement was largely good (k values: 0.5–0.83). Except for the feature “gas in SI joint” where ZTE exhibited significantly lower scores than CT (p < 0.001), ZTE and BB showed similar performance relative to CT for all other features (p > 0.52) with inter-modality agreement being substantial to almost perfect (Krippendorff’s alpha coefficients: 0.724–0.983). When combining the data from all features except for gas in the SI joint and when binarizing grading scores, combined sensitivity/specificity was 76.7%/98.6% for ZTE and 80.8%/99.1% for BB, respectively, compared to CT. Conclusions The performance of ZTE and BB sequences was comparable to CT for bone assessment of the SI joint. These sequences may potentially serve as an alternative to CT yet without involving exposure to ionizing radiation.
Background Computed tomography (CT) is the reference standard for assessment of the bone. Magnetic resonance imaging (MRI) developments enable a CT-like visualization of the osseous structures. Purpose To assess the diagnostic performance of 3D zero-echo time (3D-ZTE) and 3D T1-weighted gradient-echo (3D-T1GRE) MRI sequences for the evaluation of lumbar facet joints (LFJs) and the detection of lumbosacral transitional vertebrae (LSTV) using CT as the reference standard. Material and Methods In total, 87 adult patients were included in this prospective study. Evaluation of degenerative changes of the facet joints at the L3/L4, L4/L5, and L5/S1 levels on both sides was performed by two readers using a 4-point Likert scale. LSTV were classified according to Castelvi et al. Image quality was quantitatively measured using the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Intra-reader, inter-reader, and inter-modality reliability were calculated using Cohen's kappa statistic. Results Intra-reader agreement for 3D-ZTE, 3D-T1GRE, and CT was 0.607, 0.751, and 0.856 and inter-reader agreement was 0.535, 0.563, and 0.599, respectively. The inter-modality agreement between 3D-ZTE and CT was 0.631 and between 3D-T1GRE and CT 0.665. A total of LSTV were identified in both MR sequences with overall comparable accuracy compared to CT. Mean SNR for bone, muscle, and fat was highest for 3D-T1GRE and mean CNR was highest for CT. Conclusion 3D-ZTE and 3D-T1GRE MRI sequences can assess the LFJs and LSTV and may serve as potential alternatives to CT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.