The OI is an objective and reliable method for scoring BR. Its reproducibility was the highest of all the four modalities. The keratograph is recommended, therefore, as a suitable alternative for BR assessment.
Purpose: To use hard palate mucoperiosteum to reconstruct the upper eyelid wisely and to evaluate its function and outcome. Methods: In this case series, medial or lateral defects of the upper eyelid were reconstructed with a hard palate mucoperiosteum graft and a bandage contact lens to protect the cornea. Slit-lamp examinations, in vivo confocal microscopy, patient surveys, and pathologic examinations were performed as evaluations. Results: Seven patients were included in this study. The average follow-up time was 21.9 months. Postoperatively, all patients maintained their preoperative corneal transparency, and the best-corrected visual acuities remained stable. Postoperative corneal examination by in vivo confocal microscopy was similar to the normal contralateral eye in all cases. All hard palate mucoperiosteal grafts merged smoothly with the normal tarsoconjunctiva. The mean ratio of the graft length to the upper eyelid decreased from 48.6% during the operation to 32.2% during the follow-up; the average shrinkage rate was 16.3% ± 7.1%. Both in vivo confocal microscopy and the pathologic examinations showed that stratified squamous epithelium comprised the main part of the hard palate graft. All patients could blink normally and had a relatively normal appearance. All patients were satisfied with the overall outcome of this therapy. Main complications included loss of eyelashes (100%), abnormal curvature of the eyelid (28.5%), mild lagophthalmos (14.3%), trichiasis (14.3%), and slight exfoliation of the corneal epithelium (42.8%). Conclusions: not only effectively reconstructs the upper eyelid but also provides protection for the cornea.
Backgroud Previous studies of internal graft-host malappositions have not dealt with the precise ways in which each malapposition affected post-penetrating keratoplasty (post-PK) visual outcomes. In this study, we reviewed our post-PK and post-deep anterior lamellar keratoplasty (post-DALK) keratoconic patients and used anterior segment optical coherence tomography (AS-OCT) to evaluate the associations between graft-host interface (GHI) characteristics and visual outcomes. Methods Novel GHI metrics included: mean graft-host touch (GHT), total prevalence of malapposition proportion (Pm), frequency of apposition (F), size of malapposition (Sm), junctional graft thickness (Tg), junctional host thickness (Th) and the absolute value of difference between Tg and Th (|Tg-Th|). We connected the external and internal junction points of GHI (GHT) and drew a straight line through the central point, perpendicular to both sides of the cornea. Tg and Th were the thicknesses at cross-points 1 mm away from the meeting point on the external side of the graft and host, respectively. Linear regression analysis was used to describe associations between GHI metrics and postsurgical visual outcomes [logarithm of minimum angle of resolution best-corrected visual acuity (logMAR BCVA), spherical equivalent diopter (SE), diopter of spherical power (DS), diopter of cylindrical power (DC) and keratometric astigmatism (Astig value)]. Results We enrolled 22 post-PK and 23 post-DALK keratoconic patients. Compared with the regular-apposition results, GHT was decreased in step and gape patterns, and increased in hill and tag patterns. SE increased averagely by 6.851, 5.428 and 5.164 diopter per 1% increase in: F (step) [β = 6.851; 95% Confidence interval (CI) = 2.975–10.727; P = 0.001]; F (graft step) [β = 5.428; 95% CI = 1.685–9.171; P = 0.005]; and Pm [β = 5.164; 95%CI = 0.913–9.146; P = 0.018], respectively. SE increased averagely by 0.31 diopter per 10-μm increment in |Tg-Th| [β = 0.031; 95% CI = 0.009–0.054; P = 0.007]. LogMAR BCVA increased (on average) by 0.01 per 10-μm increment in both GHT [β = 0.001; 95% CI = 0–0.002; P = 0.030]. and Tg [β = 0.001; 95% CI = 0.001–0.002; P = 0.001]. Astig value increased on average by 0.17 diopter per 10-μm increment in Sm [β = 0.017; 95% CI = 0–0.033; P = 0.047]. Conclusion This investigation of GHI characteristics suggests explanations for varied ametropia in keratoconic eyes and has potential significance as a reference for promoting pre-surgical planning and technology for corneal transplantation.
In vivo CRISPR gene therapy holds large clinical potential, but the safety and efficacy remain largely unknown. Here, we injected a single dose of HSV-1-targeting CRISPR formulation in the cornea of three patients with severe refractory herpes stromal keratitis (HSK) during corneal transplantation. Our study is an investigated initiated, open-label, single-arm, non-randomized interventional trial at a single center (NCT04560790). We found neither detectable CRISPR-induced off-target cleavages by GUIDE-seq nor systemic adverse events for 18 months on average in all three patients. The HSV-1 remained undetectable during the study. Our preliminary clinical results suggest that in vivo gene editing targeting the HSV-1 genome holds acceptable safety as a potential therapy for HSK.
Backgroud: Previous studies of internal graft-host malappositions have not dealt with the precise ways in which each malapposition affected post-penetrating keratoplasty (post-PK) visual outcomes. In this study, we reviewed our post-PK and post-deep anterior lamellar keratoplasty (post-DALK) keratoconic patients and used anterior segment optical coherence tomography (AS-OCT) to evaluate the associations between graft-host interface (GHI) characteristics and visual outcomes. Methods: Novel GHI metrics included: mean graft-host touch (GHT), total prevalence of malapposition proportion (Pm), frequency of apposition (F), size of malapposition (Sm), junctional graft thickness (Tg), junctional host thickness (Th) and the absolute value of difference between Tg and Th (|Tg-Th|). We connected the external and internal junction points of GHI (GHT) and drew a straight line through the central point, perpendicular to both sides of the cornea. Tg and Th were the thicknesses at cross-points 1 mm away from the meeting point on the external side of the graft and host, respectively. Linear regression analysis was used to describe associations between GHI metrics and postsurgical visual outcomes [ logarithm of minimum angle of resolution best-corrected visual acuity (logMAR BCVA), spherical equivalent diopter (SE), diopter of spherical power (DS), diopter of cylindrical power (DC) and keratometric astigmatism (Astig value)]. Results: We enrolled 22 post-PK and 23 post-DALK keratoconic patients. Compared with the regular-apposition results, GHT was decreased in step and gape patterns, and increased in hill and tag patterns. SE increased averagely by 6.851, 5.428 and 5.164 diopter per 1% increase in: F (step) [β=6.851; 95% Confidence interval (CI)=2.975-10.727; P=0.001]; F (graft step) [β=5.428; 95% CI=1.685-9.171; P=0.005]; and Pm [β=5.164; 95%CI=0.913-9.146; P=0.018], respectively. SE increased averagely by 0.31 diopter per 10-μm increment in |Tg-Th| [β=0.031; 95% CI=0.009-0.054; P=0.007]. LogMAR BCVA increased (on average) by 0.01 per 10-μm increment in both GHT [β=0.001; 95% CI=0-0.002; P=0.030]. and Tg [β=0.001; 95% CI=0.001-0.002; P=0.001]. Astig value increased on average by 0.17 diopter per 10-μm increment in Sm [β=0.017; 95% CI=0-0.033; P=0.047]. Conclusion: This investigation of GHI characteristics suggests explanations for varied ametropia in keratoconic eyes and has potential significance as a reference for promoting pre-surgical planning and technology for corneal transplantation.
Backgroud: Previous studies of internal graft-host malappositions have not dealt with the precise ways in which each malapposition affected post-penetrating keratoplasty (post-PK) visual outcomes. In this study, we reviewed our post-PK and post-deep anterior lamellar keratoplasty (post-DALK) keratoconic patients and used anterior segment optical coherence tomography (AS-OCT) to evaluate the associations between graft-host interface (GHI) characteristics and visual outcomes. Methods: Novel GHI metrics included: mean graft-host touch (GHT), total prevalence of malapposition proportion (Pm), frequency of apposition (F), size of malapposition (Sm), junctional graft thickness (Tg),junctional host thickness (Th) and the absolute value of difference between Tg and Th (|Tg-Th|). We connected the external and internal junction points of GHI (GHT) and drew a straight line through the central point, perpendicular to both sides of the cornea. Tg and Th were the thicknesses at cross-points 1 mm away from the meeting point on the external side of the graft and host, respectively. Linear regression analysis was used to describe associations between GHI metrics and postsurgical visual outcomes [ logarithm of minimum angle of resolution best-corrected visual acuity (logMAR BCVA), spherical equivalent diopter (SE), diopter of spherical power (DS), diopter of cylindrical power (DC) and keratometric astigmatism (Astig value)]. Results: We enrolled 22 post-PK and 23 post-DALK keratoconic patients. Compared with the regular-apposition results, GHT was decreased in step and gape patterns, and increased in hill and tag patterns. SE increased averagely by 6.851, 5.428 and 5.164 diopter per 1% increase in: F (step) [β=6.851; 95% Confidence interval (CI)=2.975-10.727; P=0.001]; F (graft step) [β=5.428; 95% CI=1.685-9.171; P=0.005]; and Pm [β=5.164; 95%CI=0.913-9.146; P=0.018], respectively. SE increased averagely by 0.31 diopter per 10-μm increment in |Tg-Th| [β=0.031; 95% CI=0.009-0.054; P=0.007]. LogMAR BCVA increased (on average) by 0.01 per 10-μm increment in both GHT [β=0.001; 95% CI=0-0.002; P=0.030]. and Tg [β=0.001; 95% CI=0.001-0.002; P=0.001]. Astig value increased on average by 0.17 diopter per 10-μm increment in Sm [β=0.017; 95% CI=0-0.033; P=0.047]. Conclusion: This investigation of GHI characteristics suggests explanations for varied ametropia in keratoconic eyes and has potential significance as a reference for promoting pre-surgical planning and technology for corneal transplantation.
Background: Previous studies of internal graft-host malappositions have not dealt with the precise ways in which each wound malapposition affected post-keratoplasty visual outcomes. In this study, reviewing our postsurgical keratoconic patients using anterior segment optical coherence tomography (AS-OCT) to evaluate the correlation between characteristics of the graft-host interface (GHI) and visual outcomes was aimed. Methods: Correlations between characteristics of GHI and the postsurgical visual outcomes, including logarithm of minimum angle of resolution best-corrected visual acuity (logMAR BCVA), spherical equivalent diopter (SE), diopter of spherical power (DS), diopter of cylindrical power (DC), and keratometric astigmatism, were evaluated of 45 eyes (patients). Results: The graft-host touch (GHT) varied with different alignment patterns. LogMAR BCVA correlated positively with GHT (r=0.32, P=0.030) and junctional graft thickness (Tg) (r=0.49, P=0.001). SE had positive correlation with frequency of step [F (step)] (r=0.46, P=0.001), graft step [F (graft step)] (r=0.40, P=0.028), total prevalence of malapposition proportion (Pm) (r=0.35, P=0.018), size of malapposition (Sm) (r=0.31, P=0.037), Tg (r=0.03, P=0.022), disparity between junctional graft and host thickness (|Tg-Th|) (r=0.40, P=0.007), and correlated negatively with GHT (r=-0.34, P=0.021). Similar results were acquired in DS. Keratometric astigmatism was found to correlate positively with Sm (r=0.30, P=0.047). Conclusion: In keratoconic eyes, corneal keratometric astigmatism increased by 0.017 with Sm. LogMAR BCVA increased by 0.001 with both GHT and Tg. Investigation of the visions for keratoconus patients. Our study might have potential reference value for future technological promotion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.