Endovaginal US was as accurate as MR imaging in the diagnosis of uterine adenomyosis. Use of a JZ thickness of > or= 12 mm should further optimize the diagnostic accuracy of MR imaging.
By comparing the resultant change in net absorbance between the latest EBT-2 and previous EBT GAFCHROMIC film models, the authors conclude that the addition of the yellow marker dye to the sensitive layer does not affect dosimetric properties of the latest film model. The authors also describe a procedure by which one can establish an acceptable time window around chosen postirradiation scanning time protocol that would provide an acceptable dose error for practical purposes.
Splenic hemangiomas showed signal intensity characteristics and enhancement patterns similar to those described for hepatic hemangiomas. Since these features have been shown to reliably distinguish hemangiomas from other benign and malignant liver lesions, it may be reasonable to consider without histologic verification that lesions in the spleen with these imaging features represent hemangiomas.
A radiochromic film based dosimetry system using only the green color channel of a flatbed document scanner showed superior precision if used alone in a dose range that extends up to 50 Gy, which greatly decreases the complexity of work. In addition, Solid Water™ material was shown to be a viable alternative to water in performing radiochromic film based dosimetry with HDR (192)Ir brachytherapy sources.
Interleukin (IL)-12, interferon (IFN)-gamma, and other inflammatory cytokines play an important role in the pathogenesis of autoimmune insulitis and diabetes in NOD mice, and inhibition of these cytokines is likely to be beneficial. In this study, we found that Pentoxifylline (PTX) and Rolipram (phosphodiesterase [PDE] inhibitors that induce increased intracellular cAMP) can block inflammatory cytokine production. Inhibition of IL-12 and IFN-gamma secretion was demonstrated in macrophages activated with lipopolysaccharide or T-cells stimulated through the CD3/T-cell receptor complex, respectively. Moreover, strong inhibition of IL-12 was demonstrated in vivo in superantigen-immunized mice. Rolipram was inhibitory at concentrations as low as 10(-8) to 10(-7) mol/l, and on a molar basis, it was 100-fold more effective than PTX. Tumor necrosis factor-alpha was also inhibited, but IL-4 was less sensitive to suppression. In NOD mice, both PTX and Rolipram reduced the severity of insulitis and prevented diabetes, with or without cyclophosphamide administration (which precipitates onset of disease). This protection of NOD mice was still apparent over 10 weeks after withdrawal of the drug treatment. It appears that blocking the activity of type IV PDE is sufficient to mediate the effects reported in this study, since Rolipram inhibits only this isoform, unlike PTX (a general inhibitor). PTX and Rolipram may be effective in the treatment of autoimmune diabetes or other conditions characterized by excessive production of inflammatory cytokines.
Results of our investigation revealed that the use of XR-QA2 GafChromic™ film is accompanied by a rather pronounced energy dependent response for beam qualities used for x-ray based diagnostic imaging purposes. The authors also found that the most appropriate function for the reference radiochromic film dosimetry would be the power function, while for the relative dosimetry one may use the exponential response function that can be easily linearized.
In this work, the authors report on an undoubted impact of radiochromic film immersion in water on the measured change in optical density, which may lead to systematic errors in dose measurements if the film is kept in water for longer periods of time. The magnitude of the impact depends on many parameters: Size of the film piece, initial optical density, postimmersion waiting time prior to scanning (defined by the current radiochromic film dosimetry protocol in. place), and the time film was kept in water. The authors also suggested various approaches in correcting for the change in netOD due to water penetration into the film, but the authors believe that the use of the control film piece would be the most appropriate.
The photoneutron fluence per MU produced by the 10 MV FFF beam is 37% lower than the 10 MV beam of a Varian TrueBeam linac. Accordingly, a reduction in neutron dose received by patients is achieved through use of the unflattened beam, provided that treatment plans for each beam require approximately the same number of MU. It was found to be instructive to compare the photoneutron yield per source electron between the two beams as it helped provide an understanding of the physics underlying photoneutron production in both beams.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.