Three-dimensional printing has been recently proposed and assessed for continuous flow microfluidic devices. In this paper the focus is on a new application of this rapid and low cost method for microfluidic device prototyping: droplets production through a T-junction generator. The feasibility of this new methodology is assessed by means of an experimental study in which the statistical parameters which characterize the production of droplets are analyzed. Furthermore, this study assesses the validity of previous theoretical and experimental results, obtained for a PDMS T-junction droplet generator, also in the case of a 3D printed Acrylonitrile microfluidic chip. Finally, the feasibility of producing monodisperse droplets by analyzing the polydispersity index of the prepared droplets is demonstrated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.