Capacitive deionization (CDI) as a class of electrochemical desalination has attracted fast-growing research interest in recent years. A significant part of this growing interest is arguably attributable to the premise that CDI is energy efficient and has the potential to outcompete other conventional desalination technologies. In this review, systematic evaluation of literature data reveals that while the absolute energy consumption of CDI is in general low, most existing CDI systems achieve limited energy efficiency from a thermodynamic perspective. We also analyze the causes for the relatively low energy efficiency and discuss factors that may lead to enhanced energy efficiency for CDI.
Understanding the salt−water separation mechanisms of reverse osmosis (RO) membranes is critical for the further development and optimization of RO technology. The solutiondiffusion (SD) model is widely used to describe water and salt transport in RO, but it does not describe the intricate transport mechanisms of water molecules and ions through the membrane.In this study, we develop an ion transport model for RO, referred to as the solution-friction model, by rigorously considering the mechanisms of partitioning and the interactions among water, salt ions, and the membrane. Ion transport through the membrane is described by the extended Nernst−Planck equation, with the consideration of frictions between the species (i.e., ion, water, and membrane matrix). Water flow through the membrane is governed by the hydraulic pressure gradient and the friction between the water and membrane matrix as well as the friction between water and ions. The model is validated using experimental measurements of salt rejection and permeate water flux in a lab-scale, cross-flow RO setup. We then investigate the effects of feed salt concentration and hydraulic pressure on salt permeability, demonstrating strong dependence of salt permeability on feed salt concentration and applied pressure, starkly disparate from the SD model. Lastly, we develop a framework to analyze the pressure drop distribution across the membrane, demonstrating that cross-membrane transport dominates the overall pressure drop in RO, in marked contrast to the SD model that assumes no pressure drop across the membrane.
Capacitive deionization (CDI) is an emerging technology capable of selective removal of ions from water. While many studies have reported chemically tailored electrodes for selective ion removal, the selective removal of divalent cations (i.e., hardness) over monovalent cations can simply be achieved using membrane CDI (MCDI) equipped with ion exchange membranes (IEMs). In this study, we use both experimental and modeling approaches to systematically investigate the selective removal of Ca2+ over Na+. Specifically, the impacts of current density, hydraulic retention time, and feed composition on the selectivity of Ca2+ over Na+ were investigated. The results from our study suggest a universal correlation between the ratio of molar fluxes and the ratio of spacer channel ion concentrations, regardless of operating conditions and feed composition. Our analysis also reveals inherent and universal trade-off relationships between selectivity and the Ca2+ removal rate and between selectivity and the degree of Ca2+ removal. This fundamental understanding of the mechanism of selective ion removal in MCDI can also be applied to flow-electrode CDI processes that employ IEMs.
With the increasing severity of global water scarcity, a myriad of scientific activities is directed toward advancing brackish water desalination and wastewater remediation technologies. Flow-electrode capacitive deionization (FCDI), a newly developed electrochemically driven ion removal approach combining ion-exchange membranes and flowable particle electrodes, has been actively explored over the past seven years, driven by the possibility of energy-efficient, sustainable, and fully continuous production of high-quality fresh water, as well as flexible management of the particle electrodes and concentrate stream. Here, we provide a comprehensive overview of current advances of this interesting technology with particular attention given to FCDI principles, designs (including cell architecture and electrode and separator options), operational modes (including approaches to management of the flowable electrodes), characterizations and modeling, and environmental applications (including water desalination, resource recovery, and contaminant abatement). Furthermore, we introduce the definitions and performance metrics that should be used so that fair assessments and comparisons can be made between different systems and separation conditions. We then highlight the most pressing challenges (i.e., operation and capital cost, scale-up, and commercialization) in the full-scale application of this technology. We conclude this state-of-the-art review by considering the overall outlook of the technology and discussing areas requiring particular attention in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.