Tendon formation and repair rely on specific combinations of transcription factors, growth factors, and mechanical parameters that regulate the production and spatial organization of type I collagen. Here, we investigated the function of the zinc finger transcription factor EGR1 in tendon formation, healing, and repair using rodent animal models and mesenchymal stem cells (MSCs). Adult tendons of Egr1 -/-mice displayed a deficiency in the expression of tendon genes, including Scx, Col1a1, and Col1a2, and were mechanically weaker compared with their WT littermates. EGR1 was recruited to the Col1a1 and Col2a1 promoters in postnatal mouse tendons in vivo. Egr1 was required for the normal gene response following tendon injury in a mouse model of Achilles tendon healing. Forced Egr1 expression programmed MSCs toward the tendon lineage and promoted the formation of in vitro-engineered tendons from MSCs. The application of EGR1-producing MSCs increased the formation of tendon-like tissues in a rat model of Achilles tendon injury. We provide evidence that the ability of EGR1 to promote tendon differentiation is partially mediated by TGF-β2. This study demonstrates EGR1 involvement in adult tendon formation, healing, and repair and identifies Egr1 as a putative target in tendon repair strategies.
The remplissage technique did not alter the range of motion of the shoulder compared with Bankart procedure alone; however, one third of patients did experience posterosuperior pain.
This protocol allows identification of the culprit lesion in 69.2% of cases. The body mass index determines the causative lesion, as does trauma sustained within the month preceding the onset of the pain.
Coccygectomy is a controversial operation. Some authors have reported good results, but others advise against the procedure. The criteria for selection are ill-defined. We describe a study to validate an objective criterion for patient selection, namely radiological instability of the coccyx as judged by intermittent subluxation or hypermobility seen on lateral dynamic radiographs when sitting.We enrolled prospectively 37 patients with chronic pain because of coccygeal instability unrelieved by conservative treatment who were not involved in litigation. The operation was performed by the same surgeon. Patients were followed up for a minimum of two years after coccygectomy, with independent assessment at two years. There were 23 excellent, 11 good and three poor results. The mean time to definitive improvement was four to eight months. Coccygectomy gave good results in this group of patients.
AimTo assess the impact of the implementation of a Computerized Physician Order Entry (CPOE) associated with a pharmaceutical checking of medication orders on medication errors in the 3 stages of drug management (i.e. prescription, dispensing and administration) in an orthopaedic surgery unit.MethodsA before-after observational study was conducted in the 66-bed orthopaedic surgery unit of a teaching hospital (700 beds) in Paris France. Direct disguised observation was used to detect errors in prescription, dispensing and administration of drugs, before and after the introduction of computerized prescriptions. Compliance between dispensing and administration on the one hand and the medical prescription on the other hand was studied. The frequencies and types of errors in prescribing, dispensing and administration were investigated.ResultsDuring the pre and post-CPOE period (two days for each period) 111 and 86 patients were observed, respectively, with corresponding 1,593 and 1,388 prescribed drugs. The use of electronic prescribing led to a significant 92% decrease in prescribing errors (479/1593 prescribed drugs (30.1%) vs 33/1388 (2.4%), p < 0.0001) and to a 17.5% significant decrease in administration errors (209/1222 opportunities (17.1%) vs 200/1413 (14.2%), p < 0.05). No significant difference was found in regards to dispensing errors (430/1219 opportunities (35.3%) vs 449/1407 (31.9%), p = 0.07).ConclusionThe use of CPOE and a pharmacist checking medication orders in an orthopaedic surgery unit reduced the incidence of medication errors in the prescribing and administration stages. The study results suggest that CPOE is a convenient system for improving the quality and safety of drug management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.