BackgroundNear-infrared (NIR) fluorescence is a promising novel imaging technique that can aid in intraoperative demarcation of pancreatic cancer (PDAC) and thus increase radical resection rates. This study investigated SGM-101, a novel, fluorescent-labeled anti-carcinoembryonic antigen (CEA) antibody. The phase 1 study aimed to assess the tolerability and feasibility of intraoperative fluorescence tumor imaging using SGM-101 in patients undergoing a surgical exploration for PDAC.MethodsAt least 48 h before undergoing surgery for PDAC, 12 patients were injected intravenously with 5, 7.5, or 10 mg of SGM-101. Tolerability assessments were performed at regular intervals after dosing. The surgical field was imaged using the Quest NIR imaging system. Concordance between fluorescence and tumor presence on histopathology was studied.ResultsIn this study, SGM-101 specifically accumulated in CEA-expressing primary tumors and peritoneal and liver metastases, allowing real-time intraoperative fluorescence imaging. The mean tumor-to-background ratio (TBR) was 1.6 for primary tumors and 1.7 for metastatic lesions. One false-positive lesion was detected (CEA-expressing intraductal papillary mucinous neoplasm). False-negativity was seen twice as a consequence of overlying blood or tissue that blocked the fluorescent signal.ConclusionThe use of a fluorescent-labeled anti-CEA antibody was safe and feasible for the intraoperative detection of both primary PDAC and metastases. These results warrant further research to determine the impact of this technique on clinical decision making and overall survival.
Background Tumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery. Intraoperative navigation using fluorescence guidance is an innovative technique enabling real-time identification of (sub)capsular liver tumors. The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver. Methods Patients undergoing laparoscopic resection of a malignant hepatic tumor were eligible for inclusion. Patients received standard-of-care, including preoperative CT and/or MRI. In addition, 10 mg indocyanine green was intravenously administered one day prior to surgery. After introduction of the laparoscope, inspection, FI, and laparoscopic ultrasonography (LUS) were performed. Histopathological examination of resected suspect tissue was considered the gold standard. Results Twenty-two patients suspected to have hepatocellular carcinoma (n=4), cholangiocarcinoma (n=2) or liver metastases from colorectal carcinoma (n=12), uveal melanoma (n=2) and breast cancer (n=2) were included. Two patients were excluded because their surgery was unexpectedly postponed several days. Twenty-six malignancies were resected in the remaining 20 patients. Sensitivity for various modalities was 80% (CT), 84% (MRI), 62% (inspection), 86% (LUS) and 92% (FI), respectively. Three metastases (12%) were identified solely by FI. All 26 malignancies could be detected by combining LUS and FI (100% sensitivity). Conclusion This study demonstrates added value of FI during laparoscopic resections of several hepatic tumors. Although larger series will be needed to confirm long-term patient outcome, the technology already aids the surgeon by providing real-time fluorescence guidance.
Background: Fluorescence cholangiography using indocyanine green (ICG) can enhance orientation of bile duct anatomy during laparoscopic cholecystectomy. To ensure clear discrimination between bile ducts and liver, the fluorescence ratio between both should be sufficient. This ratio is influenced by the ICG dose and timing of fluorescence imaging. We first systematically identified all strategies for fluorescence cholangiography. Second, we aimed to optimize the dose of ICG and dosing time in a prospective clinical trial. Methods: PubMed was searched for clinical trials studying fluorescence cholangiography. Furthermore, 28 patients planned to undergo laparoscopic cholecystectomy were divided into 7 groups, receiving different intravenous doses (5 or 10 mg ICG) at different time points (0.5, 2, 4, 6, or 24 hours prior to surgery). Results: The systematic review revealed 27 trials including 1057 patients. The majority of studies used 2.5 mg administered within 1 hour before imaging. Imaging 3 to 24 hours after ICG administration was never studied. The clinical trial demonstrated that the highest bile duct-to-liver ratio was achieved 3 to 7 hours after administration of 5 mg and 5 to 25 hours after administration of 10 mg ICG. Up to 3 hours after administration of 5 mg and up to 5 hours after administration of 10 mg ICG, the liver was equally or more fluorescent than the cystic duct, resulting in a ratio ≤1.0. Conclusion: This study shows for the first time that the interval between ICG administration and intraoperative fluorescence cholangiography should be extended. Administering 5 mg ICG at least 3 hours before imaging is easy to implement in everyday clinical practice and results in bile duct-to-liver ratios >1.0.
BACKGROUND Several studies demonstrated that intraoperative near-infrared fluorescence (NIRF) imaging using indocyanine green (ICG) identifies (sub)capsular colorectal liver metastases (CRLM) missed by other techniques. It is unclear if this results in any survival benefit. This study evaluates long-term follow-up after NIRF-guided resection of CRLM using ICG. METHODS First, patients undergoing resection of CRLM with or without NIRF imaging were analyzed retrospectively. Perioperative details, liver-specific recurrence-free interval and overall survival were compared. Second, the prognosis of patients in whom additional metastases were identified solely by NIRF was studied. RESULTS Eighty-six patients underwent resection with NIRF imaging and 87 without. In significantly more patients of the NIRF imaging cohort additional metastases were identified during surgery (25% vs. 13%, p=0.04). Tumors identified solely by NIRF imaging were significantly smaller compared to additional metastases identified also by inspection, palpation or intraoperative ultrasound (3.2 ± 1.8 mm vs. 7.4 ± 2.6 mm, p<0.001). Liver-specific recurrence-free survival at 4 years was 47% with NIRF imaging and 39% without (hazard ratio at multivariate analysis 0.73, 95%CI 0.42–1.28, p=0.28). Overall survival at 4 years was 62% and 59%, respectively (p=0.79). No liver recurrences occurred within 3 years follow-up in 52% of patients in whom additional metastases were resected based on only NIRF imaging. CONCLUSIONS This study suggests that NIRF imaging identifies significantly more and smaller tumors during resection of CRLM, preventing recurrences in a subset of patients. Given its safety profile and low expense, routine use can be considered until tumor targeting fluorescent tracers are clinically available. Keywords: .
Incomplete resections and damage to critical structures increase morbidity and mortality of patients with cancer. Targeted intraoperative fluorescence imaging aids surgeons by providing real-time visualization of tumors and vital structures. This study evaluated the tumor-targeted zwitterionic near-infrared fluorescent peptide cRGD-ZW800-1 as tracer for intraoperative imaging of multiple cancer types. cRGD-ZW800-1 was validated in vitro on glioblastoma (U-87 MG) and colorectal (HT-29) cell lines. Subsequently, the tracer was tested in orthotopic mouse models with HT-29, breast (MCF-7), pancreatic (BxPC-3), and oral (OSC-19) tumors. Dose-ranging studies, including doses of 0.25, 1.0, 10, and 30 nmol, in xenograft tumor models suggest an optimal dose of 10 nmol, corresponding to a human equivalent dose of 63 μg/kg, and an optimal imaging window between 2 and 24 h post-injection. The mean half-life of cRGD-ZW800-1 in blood was 25 min. Biodistribution at 4 h showed the highest fluorescence signals in tumors and kidneys. In vitro and in vivo competition experiments showed significantly lower fluorescence signals when U-87 MG cells (minus 36%, p = 0.02) or HT-29 tumor bearing mice (TBR at 4 h 3.2 ± 0.5 vs 1.8 ± 0.4, p = 0.03) were simultaneously treated with unlabeled cRGD. cRGD-ZW800-1 visualized in vivo all colorectal, breast, pancreatic, and oral tumor xenografts in mice. Screening for off-target interactions, cRGD-ZW800-1 showed only inhibition of COX-2, likely due to binding of cRGD-ZW800-1 to integrin αVβ3. Due to its recognition of various integrins, which are expressed on malignant and neoangiogenic cells, it is expected that cRGD-ZW800-1 will provide a sensitive and generic tool to visualize cancer during surgery.
Folate receptor alpha (FRα) is known to be upregulated in a variety of cancers, including non-small cell lung cancer (NSCLC) and breast cancer. To ensure reliable implementation of diagnostic- and therapeutic agents, concordance of FRα expression between biopsy, primary tumor and metastases is important. Using immunohistochemistry (Mab 26B3.F2) these concordances were investigated in 60 NSCLC and 40 breast cancer patients. False positivity of FRα expression on breast and lung cancer biopsies was limited to less than 5%. In NSCLC, FRα expression was shown in 21/34 adenocarcinomas and 4/26 squamous cell carcinomas (SCC). Concordance of FRα expression between biopsy and primary tumor was achieved in respectively 83% and 91% of adenocarcinomas and SCCs. Approximately 80% of all local and distant metastases of NSCLC patients showed concordant FRα expression as their corresponding primary tumor. In breast cancer, FRα positivity was shown in 12/40 biopsies, 20/40 lumpectomies and 6/20 LN metastases, with concordance of 68% between biopsy and primary tumor and 60% between primary tumor and LN metastases. In conclusion, this study shows high concordance rates of FRα expression between biopsies and metastases compared to primary NSCLC and breast cancers, underscoring the applicability of FRα-targeted agents in these patients.
Surgery is the cornerstone of oncologic therapy with curative intent. However, identification of tumor cells in the resection margins is difficult, resulting in non-radical resections, increased cancer recurrence and subsequent decreased patient survival. Novel imaging techniques that aid in demarcating tumor margins during surgery are needed. Overexpression of carcinoembryonic antigen (CEA) is found in the majority of gastro-intestinal carcinomas, including colorectal and pancreas. We developed ssSM3E/800CW, a novel CEA-targeted near-infrared fluorescent (NIRF) tracer, based on a disulphide stabilized single-chain antibody fragment (ssScFv), to visualize colorectal and pancreatic tumors in a clinically translatable setting. The applicability of the tracer was tested for cell and tissue binding characteristics and dosing using immunohistochemistry, flow cytometry, cell-based plate assays and orthotopic colorectal (HT-29, well differentiated) and pancreatic (BXPC-3, poorly differentiated) xenogeneic human-mouse models. NIRF signals were visualized using the clinically compatible FLARE™ imaging system. Calculated clinically relevant doses of ssSM3E/800CW selectively accumulated in colorectal and pancreatic tumors/cells, with highest tumor-to-background ratios of 5.1±0.6 at 72 h post-injection, which proved suitable for intra-operative detection and delineation of tumor boarders and small (residual) tumor-nodules in mice, between 8 h and 96 h post-injection. Ex vivo fluorescence imaging and pathologic examination confirmed tumor-specificity and the distribution of the tracer. Our results indicate that ssSM3E/800CW shows promise as a diagnostic tool to recognize colorectal and pancreatic cancers for fluorescent-guided surgery applications. If successful translated clinically, this tracer could help improve the completeness of surgery and thus survival.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.