Preoperative embolization of cranial and spinal tumors can be performed safely. Specific technical advantages of Onyx included deep penetration of lesions producing extensive tumor infarction, the ability to embolize extensive portions of the tumors through fewer arterial catheterizations, and the safety of catheter withdrawal despite often substantial reflux along the embolic catheter.
Intraprocedural perforations during stent retriever thrombectomy were rare, but when they occurred were associated with high mortality. Perforations most commonly occurred at distal occlusion sites and were often characterized by difficulty traversing the occlusion with a microcatheter or microwire, or while withdrawing the stent retriever. Nevertheless, 25% of patients had a favorable functional outcome, suggesting that in some patients with this complication good neurological recovery is achievable.
Because of testing methodology, the rib cage accounted for a greater percentage of thoracic stability than previously estimated. Different rib cage structures resisted motion in different loading planes.
Thoracic short-segment fixation provides significantly less stability than long-segment fixation for the injury studied. Adding a cross-link to short fixation improved stability only during axial rotation. Adding a screw at the fracture site improved short-segment stability by an average of 25%.
Flow diversion has revolutionised the treatment of intracranial aneurysms, and the Pipeline Embolization Device (PED) remains the only flow diverter (FD) approved in the USA. However, thromboembolic events remain an issue for FDs. Attempting to minimise these incidents, a newer PED has been developed with the use of covalent bonding of phosphorylcholine onto the Pipeline device that has been known as Shield Technology (PED Shield), which in vitro has demonstrated a significant reduction in material thrombogenicity. We report the first US experience of the PED Shield in the treatment of a ruptured fusiform aneurysm located in the right vertebral artery in an attempt to mitigate complications related to the use of dual-antiplatelet therapy and discuss our rationale for using the new FD, using aspirin only as the antiplatelet regimen.
BackgroundTreatment of acute cerebrovascular pathology, such as acute ischemic stroke or intracranial aneurysms, presents a challenge if an extracranial or intracranial stent is required; immediate platelet inhibition is vital. To date, there is no standardized approach for antiplatelet inhibition in an acute setting.ObjectiveTo report our preliminary experience and lessons learnt using cangrelor in acute neurointervention.MethodsA single-arm pilot study was performed to assess the safety and efficacy of cangrelor plus aspirin for platelet inhibition in patients who require acute stenting in the setting of neuroendovascular treatment.ResultsEight patients were enrolled between October 2017 and August 2018. Median age was 71 years (53–86). Seven patients were treated in an acute setting according to the stroke protocol at our institution, while one patient was treated for a symptomatic, unruptured aneurysm with flow diversion and coiling. At admission, the median National Institutes of Health Stroke Scale score for the patients with stroke was 12.5 (range 2–22.3). Cangrelor was infused and all patients achieved adequate platelet inhibition (<200 PRU (P2Y12 reaction units)). Six of seven patients with ischemic stroke had a carotid stent placed and one had an intracranial stent deployed in the middle cerebral artery. None of the patients experienced intraprocedural thromboembolic complications, intraprocedural in-stent thrombosis, hemorrhagic complications, or stroke within 24 hours after the intervention. The majority of patients (6/8) had a good clinical outcome at discharge (modified Rankin Scale score 0–2).ConclusionsOur findings suggest that cangrelor is a promising alternative in acute stenting for the treatment of cerebrovascular pathology. However, further studies with larger samples are required to accurately elucidate its safety and effectiveness in neuroendovascular procedures.
The primary biomechanical effect of the ISS was reduced extension with associated reduced facet loads and smaller decrease in foraminal height. The ISS had little effect on sagittal IAR or on motion or facet loads in other directions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.