A surgical technique involving exact repositioning and rigid fixation is required for the reduction of fractures of the orbital floor. Even then, sequelae may be present long after the trauma. The aim of this study was to establish the frequency and type of sequelae after surgery for orbital floor fractures and to investigate the extent to which the method of surgery had any impact on the severity of the sequelae. A questionnaire was sent to all 107 patients (response rate 77%) 1 to 5 years after the injury. Further clinical data were obtained from the patients' charts. Eighty-three percent of the patients were affected by some kind of permanent sequelae in terms of sensibility, vision, and/or physical appearance. A high frequency of diplopia (36%) was related to the reconstruction of the orbital floor with a temporary "supporting" antral packing in the maxillary sinus, a technique which has now been abandoned at our department in favor of orbital restoration with sheets of porous polyethylene. Our conclusion is that, because long-term sequelae are common, the surgical technique must be subjected to continuous quality control to minimize future problems for this group of patients.
Simulated entrapment was easily detected as a distinct difference between right and left eye motility recordings (p<0.001). Recordings of patients with diplopia differed significantly from those of healthy test subjects with respect to velocity (p<0.05) and range of motility (p<0.05).
We observed that the maturation of the latency of wave I is the first to occur, and is observed during the first 6 months of life. The latency of wave III reaches a stable value at 12 months of age and the latency of waves V continues to decreases with age up to 18 months.
Conclusion:The maturation of the auditory pathways follows a rostrocaudal direction, depends on postconceptional age and is not influenced by gestational age.
Background The aim of this study was to assess patient-reported symptoms and health-related quality of life, 12 to 24 months after injury in patients with midfacial fractures.
Methods Patients diagnosed with midfacial fractures were assessed regarding symptoms related to the fracture as well as assessment of the patients overall health-related quality of life using the Gothenburg Trismus Questionnaire (GTQ), the Folkestad facial trauma questionnaire, and EuroQol five-dimensional (EQ-5D). Questionnaires were distributed to the study patients 12 to 24 months after the trauma. Medical records were retrospectively surveyed for age, gender, trauma etiology, date of injury, fracture classification, treatment regimen, and time of surgery.
Results Sixty-seven percent of the study group reports sensibility disturbance in the face 12 to 24 months after trauma and 52% reported cosmetic consequences related to the trauma. Numbness in the face was the symptom reported to be most disturbing for the patients. Few of the patients reported severe jaw-related problems, problems with muscular tension, or eating limitation according to the validated questionnaire GTQ.
Conclusion Sensibility disturbance remains a significant and common symptom 12 to 24 months after midfacial trauma. There is a need for a validated patient-reported outcome instrument for facial trauma that covers multiple aspects of facial trauma such as vision disturbance and diplopia, jaw-related problems, and facial pain as well as sensibility disturbance and cosmetic consequences.
Purpose
The present study aims to investigate how well CT images correlate to surgical findings in orbital floor fractures and to the presence of diplopia.
Methods
In this cross-sectional study, 27 consecutive patients already selected for surgery due to an orbital floor fracture underwent a routine CT scan (axial, coronal, sagittal). An ophthalmologist established any presence of diplopia. Extent of fracture/injury seen on CT was compared to that discovered during surgery.
Results
In the surgeons´ opinions CT-images were in concordance with surgical findings in 71% of the cases. Agreement for pure blow out fractures was high (92%). Tetrapod fractures as a cause of an orbital floor fracture was only identified as such by surgeons in three of 11 cases, all subjected to orbital exploration, not only a closed reduction. Diplopia showed a significant correlation to rounding of the inferior rectus muscle at coronal CT. “Rounding” significantly correlated with the presence of a floor defect, to herniation of soft tissues and to the volume of displaced tissue.
Conclusions
The results imply that the joint professional interaction between neuroradiology and surgery is important and would benefit from the use of an easy and well-defined classification system of orbital floor fractures. In Sweden a national record to collect data on all zygomaticomaxillary complex fractures assessed is to be started aiming at making general statements possible by time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.