A description is given of a simple, prototype, pulse, pressure-gain, combustor for a gas turbine. The work reported was targeted at alleviating problems previously observed with the prototype combustor. These were related to irreversibilities, causing a performance deficiency, in the secondary flow passage. The work consisted of investigating experimentally the effect of tuning the secondary-flow path-length, adding a flow restrictor at the combining-cone entry station and redesigning the combining-cone itself. The overall result was to eradicate the previously noted performance deficiency thereby increasing the maximum pressure-gain obtained in the gas turbine from 1.6% to 4.0% of the compressor absolute delivery pressure.
Diagramas podem ser utilizados para análise de problemas complexos, facilitando decisões. Como exemplo, citam-se os diagramas bioclimáticos, utilizados para definir diretrizes para projetos de edificações. Contudo, por serem baseados em modelos de conforto térmico estáticos, os diagramas bioclimáticos não são compatíveis com a ideia do conforto térmico adaptativo. Esta pesquisa teve por objetivo apresentar diagramas de apoio ao processo de projeto de pequenas edificações de baixo consumo energético e adequados à ideia do conforto adaptativo. A partir de um modelo adaptativo de conforto e dos diagramas existentes, elaboraram-se dois diagramas e procedimentos para sua aplicação. Os diagramas foram aplicados às fases iniciais do processo de projeto de pequenas edificações no clima de Curitiba e os resultados foram comparados com os obtidos com o tradicional diagrama de Givoni. A comparação mostrou que as diferenças entre os modelos de conforto resultam em diretrizes diferentes. O método alternativo também permitiu analisar mais adequadamente a variável amplitude térmica diária e ordenar a aplicação das diretrizes projetuais.
Abstractest cells can be used for testing the thermal performance of different passive systems and building components. Predictive methods for estimating indoor air temperatures can further enhance the number of configurations tested without increasing the amount of test cells to be built. Thus, direct comparisons can be drawn for identical background climatic conditions. In its most basic form, formulas are generated by linear regression from relatively short data sets, which provide daily indoor temperature conditions. However, for more detailed analyses, daily indoor temperature predictions may not suffice. In this paper, a method for obtaining hourly indoor air temperature predictions is proposed. It is based on rising and decreasing rates of the indoor temperature fluctuation relative to outdoors, which translates to warming or cooling trends of indoor thermal conditions. The applicability of the method is for test cells. It is a simple method yet capable of predicting the thermal behavior of complex physical processes. The method was tested using measured data from experiments in a test cell, built with conventional building materials in Brazil. Results showed high performance with mean bias of 0.27 °C to measured data and Pearson's r 0.99. When compared to traditional regression-based models, the method proposed showed better results.
Keywords
Resumo O resfriamento evaporativo indireto (REI), caracterizado pela umidificação de coberturas e por produzir resfriamento sem aumentar a umidade relativa do interior da edificação, é uma estratégia de projeto bioclimático ainda relativamente pouco usada no horizonte brasileiro. O presente estudo tem por objetivo avaliar a aplicação de uma forma particular de REI (que alia o resfriamento evaporativo à inércia térmica propiciada por um reservatório d'água) para o condicionamento térmico de ambientes em situação de calor em Curitiba, cidade inserida na zona bioclimática 1. Foram confeccionados, monitorados e comparados inicialmente duas células-teste: um módulo de controle (MC) e um módulo experimental (ME), este dotado de uma cobertura estanque constituída de um reservatório d'água sujeita à evaporação. Uma segunda configuração do módulo experimental foi testada em um período de monitoramento subsequente, a qual possibilitou comparar-se o efeito do resfriamento com o reservatório vedado, ou seja, sem uso do REI, em uma situação de aumento da capacidade térmica da cobertura sem haver efeito evaporativo. Os resultados apontam para a vantagem do uso do REI para o resfriamento interno dos protótipos testados.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.