2016
DOI: 10.1016/j.buildenv.2016.07.021
|View full text |Cite
|
Sign up to set email alerts
|

Thermal performance of different configurations of a roof pond-based system for subtropical conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0
3

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 13 publications
0
9
0
3
Order By: Relevance
“…Such roofs are rarely used in architecture due to the technical complexity of building them, the need for more costly and attentive maintenance [19], the risk of interior moisture, etc. A reservoir roof stores rainwater to use as an irrigation system and is usually covered by a floating pavement that reduces water evaporation [20,21]. One advantage, among others, is the possibility of evaporative cooling inside [22].…”
Section: Reservoir Roofs and Water-covered Roofsmentioning
confidence: 99%
“…Such roofs are rarely used in architecture due to the technical complexity of building them, the need for more costly and attentive maintenance [19], the risk of interior moisture, etc. A reservoir roof stores rainwater to use as an irrigation system and is usually covered by a floating pavement that reduces water evaporation [20,21]. One advantage, among others, is the possibility of evaporative cooling inside [22].…”
Section: Reservoir Roofs and Water-covered Roofsmentioning
confidence: 99%
“…Scale or size varies from as small as an actual shoe box size with dimension smaller than 1000mm [19,20,21,22], to medium size with dimensions between 1000 to 2000mm [23,24,25,26], and to large scales of more than 2000mm [27,28,29,30,31,32,33]. Most studies include multiple test cells starting by two [22], four [20,21,23,26,27,32] or more [25].…”
Section: Previous Studiesmentioning
confidence: 99%
“…Researchers seldom study both walls and roofs simultaneously [32,33]. The main goal of the studies can vary from heat transfer [23,34] to the impact on energy loads [19], but the larger part investigates temperature: inside/ambient temperature [22,25,26,28]; surface temperature [20,25,29,30], temperature difference between inside and outside [24,26,31], maximum internal temperature [27], cooling degree days [22], and thermal comfort [32,33].…”
Section: Previous Studiesmentioning
confidence: 99%
“…Os resultados indicaram redução das médias das temperaturas internas na maioria das cidades, entre -0,8 ºC e -2,5 ºC (GONZÁLEZ-CRUZ; KRÜGER; GIORDANO, 2014). TR metálicos também foram aplicados aos climas das regiões de Florianópolis e Curitiba em pesquisas com células-teste, nas quais as médias das temperaturas internas do ar também apresentaram redução de aproximadamente 2 ºC em comparação com as médias externas (GONZÁLEZ-CRUZ et al, 2014;FERNANDES;LANGE, 2016;KRÜGER et al, 2016).…”
Section: Introductionunclassified