Current treatment with tissue painogen activator (tPA) requires an Intravenous infusion (1.5-3 h) became the clearance of tPA from the circulation is rapid (t1/2 6 min).
Access of recombinant proteins to the retina following intravitreal administration is poorly understood. A study was conducted in male Rhesus monkeys (15 to 28 mo of age; 2.8-3.3 kg) in order to compare the intraocular tissue distribution, pharmacokinetics, and safety of 125 Iodine (I)-labeled full-length humanized rhuMAb HER2 antibody (148 kD) and of 125 I-labeled humanized rhuMAb vascular endothelial growth factor Fab antibody (48.3 kD) following bilateral bolus intravitreal injection on day 0 (5 animals/group). The dose administered to each eye was 25 μg (9-10 μCi) in 50 μl. Animals were euthanatized on day 0 (1 hr postdose) and on days 1, 4, 7, and 14. Safety assessment included direct ophthalmoscopy, intraocular pressure measurements, clinical observations, body weight, and hematology and clinical chemistry panels. Blood and vitreous samples were collected daily (blood only) and at necropsy for pharmacokinetics and analysis for antibodies to the test materials; the ocular tissue distribution of the test material was evaluated by microautoradiography. All animals completed the study. Microautoradiography demonstrated that the full-length antibody did not penetrate the inner limiting membrane of the retina at any of the time points examined. In contrast, the Fab antibody fragment diffused through the neural retina to the retinal pigment epithelial layer at the 1-hr time point and persisted in this location for up to 7 days. Systemic exposure to test material was low but variable: the highest plasma concentration of the full-length antibody was 20.3 ng/ml, whereas plasma concentrations for the Fab antibody remained below the limit of quantitation (i.e., <7.8 ng/ml). An immune response to the test material was not evident in either treatment group. The half-life in vitreous was 5.6 days for the full-length antibody and 3.2 days for the Fab antibody. The shorter intravitreal half-life of the Fab antibody is related to its smaller size and its significant diffusion through the retinal layers. The differences in pharmacokinetics and tissue distribution that are noted between the full-length and Fab antibodies in this study identify potential therapeutic approaches that may be exploited in specific disease conditions.
SummarySite directed mutagenesis was used to construct a t-PA variant that contains an additional glycosylation site in the first kringle domain (T103N) combined with a tetra-alanine substitution in the protease domain (KHRR 296-299 AAAA). This combination variant has a plasma clearance rate that is 4.5-fold slower in rats and 5.4-fold slower in rabbits than t-PA. It is also less than one tenth as active as t-PA towards plasminogen in the presence of fibrinogen, and has approximately twice the normal activity in the presence of fibrin. It shows substantial resistance to the fast acting inhibitor, plasminogen activator inhibitor-1 (PAI-1), requiring a 10-fold greater molar excess of PAI-1 to reduce its activity by 50%, compared to t-PA. This is the result of a reduction of nearly 100-fold in the second order rate constant for PAI-1 inactivation. These results show that it is possible to combine mutations in different domains of t-PA to construct a variant which is simultaneously slower clearing, less reactive towards plasminogen in the absence of a fibrin clot, and resistant to inactivation by PAI-1.
Vascular endothelial growth factor (VEGF) is a potent angiogenic factor with a unique specificity for vascular endothelial cells. In addition to its role in vasculogenesis and embryonic angiogenesis, VEGF is implicated in pathologic neovascularization associated with tumors and diabetic retinopathy. Four different constructs of a short variant of VEGF sufficient for receptor binding were overexpressed in Escherichia coli, refolded, purified, and crystallized in five different space groups. In order to facilitate the production of heavy atom derivatives, single cysteine mutants were designed based on the crystal structure of platelet-derived growth factor. A construct consisting of residues 8 to 109 was crystallized in space group P2(1), with cell parameters a = 55.6 A, b = 60.4 A, c = 77.7 A, beta = 90.0 degrees, and four monomers in the asymmetric unit. Native and derivative data were collected for two of the cysteine mutants as well as for wild-type VEGF.
Poly(lactic-co-glycolic) acid (PLGA) bioresorbable microspheres are used for controlled-release drug delivery and are particularly promising for ocular indications. The objective of the current study was to evaluate the pharmacokinetics and safety of a recombinant human monoclonal antibody (rhuMAb HER2) in rabbits after bolus intravitreal administration of a solution or a PLGA-microsphere formulation. On Day 0, forty-eight male New Zealand white rabbits (2.3-2.6 kg) were immobilized with intramuscular ketamine/xylazine, and the test materials were injected directly into the vitreous compartment. Group 1 animals received rhuMAb HER2 in 50:50 lactide: glycolide PLGA microspheres; Group 2 animals received rhuMAb HER2 in solution (n = 24/group). The dose for each eye was 25 microg (50 microl). After dosing, animals were sacrificed at 2 min, and on 1, 2, 4, 7, 14, 23, 29, 37, 44, 50, and 56 days (n = 2/timepoint/group). Safety assessment included direct ophthalmoscopy, clinical observations, body weight, and hematology and clinical chemistry panels. At necropsy, vitreous and plasma were collected for pharmacokinetics and analysis for antibodies to rhuMAb HER2, and the vitreal pellet (Group 1) was prepared for histologic evaluation. All animals completed the study per protocol-both treatments were well tolerated, and no suppurative or mixed inflammatory cell reaction was observed in the vitreal samples (Group 1) at any of the time points examined. Antibodies to rhuMAb HER2 were detected in plasma samples by Day 7 in both treatment groups, but infrequently in vitreous samples. There were no safety implications associated with this immune response. The in vitro characterization of the PLGA microspheres provided reasonable projections of the in vivo rhuMAb HER2 release kinetics (Group 1). The total amount of antibody that was released was similar in vitro (25.9%) and in vivo (32.4%). RhuMAb HER2 (Group 2) was cleared slowly from the vitreous compartment, with initial and terminal half-lives of 0.9 and 5.6 days, respectively. The volume of distribution approximated the vitreous volume in a rabbit eye.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.