A hollow fiber miniaturized supported liquid membrane (SLM) device for sample preparation is connected on-line with capillary electrophoresis and used for determination of a basic drug, bambuterol, in human plasma. The analyte is extracted from the outside of the hollow fiber (donor) through the liquid membrane (pores of the fiber impregnated with organic solvent) into the acceptor solution in the fiber lumen. The process is driven by differences in pH between the donor and acceptor solution. The whole volume of the acceptor solution can then be injected into the CZE capillary by using the double-stacking procedure for large volume-injection. Very clean extracts of low ionic strength are obtained from the SLM treatment, making this sample pretreatment method compatible with the CZE double-stacking procedure, which in turn makes it possible to inject large volumes of sample onto the separation capillary. Good performance of the whole procedure is demonstrated, and detection limits in the low nanomolar range were obtained in spite of the relatively weak UV absorbance of bambuterol. Extractions through the miniaturized SLM unit can be performed for 5-6 h without regenerating the fiber. The regeneration procedure was tested, and no relevant changes in the performance of the extraction could be found after seven regenerations, allowing the same fiber to be used for a week.
The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 microm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.