As clinical magnetic resonance (MR) imaging becomes more versatile and more complex, it is increasingly difficult to develop and maintain a thorough understanding of the physical principles that govern the changing technology. This is particularly true for practicing radiologists, whose primary obligation is to interpret clinical images and not necessarily to understand complex equations describing the underlying physics. Nevertheless, the physics of MR imaging plays an important role in clinical practice because it determines image quality, and suboptimal image quality may hinder accurate diagnosis. This article provides an image-based explanation of the physics underlying common MR imaging artifacts, offering simple solutions for remedying each type of artifact. Solutions that have emerged from recent technologic advances with which radiologists may not yet be familiar are described in detail. Types of artifacts discussed include those resulting from voluntary and involuntary patient motion, magnetic susceptibility, magnetic field inhomogeneities, gradient nonlinearity, standing waves, aliasing, chemical shift, and signal truncation. With an improved awareness and understanding of these artifacts, radiologists will be better able to modify MR imaging protocols so as to optimize clinical image quality, allowing greater confidence in diagnosis.
We have imaged the configuration of trapped magnetic vortices in two-dimensional superconductor arrays and clusters using a scanning SQUID microscope (SSM). The SSM scans a dc SQUID detector over the array surface, achieving better than 10 μm spatial resolution over a scan range up to 1 cm×1 cm and a magnetic flux sensitivity of about 10−4Φ0. We have obtained images of large square arrays cooled at different values of applied magnetic flux per cell Φ. For low rational values (1/2,1/3,1/4,...) of the frustration parameter f=Φ/Φ0, we find regions of periodically arranged vortices separated by domain walls; at other values of the field, the vortex pattern is disordered. We also present observations of vortex patterns in ensembles of 3×3 clusters.
To evaluate colorectal cancer hepatic metastasis detection and characterization between reduced radiation dose (RD) and standard dose (SD) contrast material-enhanced CT of the abdomen and to qualitatively compare between filtered back projection (FBP) and iterative reconstruction algorithms. Materials and Methods:In this prospective study (from May 2017 through November 2017), 52 adults with biopsy-proven colorectal cancer and suspected hepatic metastases at baseline CT underwent two portal venous phase CT scans: SD and RD in the same breath hold. Three radiologists, blinded to examination details, performed detection and characterization of 2-15-mm lesions on the SD FBP and RD adaptive statistical iterative reconstruction (ASIR)-V 60% series images. Readers assessed overall image quality and lesions between SD FBP and seven different iterative reconstructions. Two nonblinded consensus reviewers established the reference standard using the picture archiving and communication system lesion marks of each reader, multiple comparison examinations, and clinical data.Results: RD CT resulted in a mean dose reduction of 54% compared with SD. Of the 260 lesions (233 metastatic, 27 benign), 212 (82%; 95% confidence interval [CI]: 76%, 86%) were detected with RD CT, whereas 252 (97%; 95% CI: 94%, 99%) were detected with SD (P , .001); per-lesion sensitivity was 79% (95% CI: 74%, 84%) and 94% (95% CI: 90%, 96%) (P , .001), respectively. Mean qualitative scores ranked SD images as higher quality than RD series images, and ASIR-V ranked higher than ASIR and Veo 3.0. Conclusion:CT evaluation of colorectal liver metastases is compromised with modest radiation dose reduction, and the use of iterative reconstructions could not maintain observer performance.
BackgroundThere is strong evidence that breastfeeding (BF) significantly benefits mothers and infants in various ways. Yet the proportion of breastfed babies in Vietnam is low and continues to decline. This study fills an important evidence gap in BF practices in Vietnam.ObjectiveThis paper examines the trend of early initiation of BF and exclusive BF from 2000 to 2011 in Vietnam and explores the determinants at individual and contextual levels.DesignData from three waves of the Multiple Indicator Cluster Survey were combined to estimate crude and adjusted trends over time for two outcomes – early initiation of BF and exclusive BF. Three-level logistic regressions were fitted to examine the impacts of both individual and contextual characteristics on early initiation of BF and exclusive BF in the 2011 data.ResultsBoth types of BF showed a decreasing trend over time after controlling for individual-level characteristics but this trend was more evident for early initiation of BF. Apart from child's age, individual-level characteristics were not significant predictors of the BF outcomes, but provincial characteristics had a strong association. When controlling for individual-level characteristics, mothers living in provinces with a higher percentage of mothers with more than three children were more likely to have initiated early BF (odds ratio [OR]: 1.06; confidence interval [CI]: 1.02–1.11) but less likely to exclusively breastfeed their babies (OR: 0.94; CI: 0.88–1.01). Mothers living in areas with a higher poverty rate were more likely to breastfeed exclusively (OR: 1.07; CI: 1.02–1.13), and those who delivered by Caesarean section were less likely to initiate early BF.ConclusionsOur results suggest that environmental factors are becoming more important for determining BF practices in Vietnam. Intervention programs should therefore not only consider individual factors, but should also consider the potential impact of contextual factors on BF practices.
BackgroundThe Expanded Program on Immunization currently considers offering Human Papilomavirus vaccine on a routine basis in Vietnam. However, as the current available vaccine can prevent only two types HPV 16 and 18, before implementing a large-scale vaccine campaign we need information about the prevalence of infection with only HPV 16 and 18 in Viet Nam. This study was done in 5 large cities in Vietnam to estimate the prevalence of HPV 16 and/or 18 infections and to explore the distribution of other high risk types of HPV among married women in these provinces.MethodsThe study employed a cross-sectional design with multistage sampling. The sample size included 4500 married women in two rounds (aged ranged from 18-69 years old, median age: 40 year old). Participant were randomly selected, interviewed and given gynaecological examinations. HPV infection status (by real-time PCR kit using TaqMan probe) and HPV genotyping test (by Reverse dot blot) were done for all participants.ResultsThe prevalence of cervical infection with HPV type 16 and/or 18 among married women in this study ranged from 3.1% to 7.4%. Many positive HPV cases (ranged from 24.5% to 56.8%) were infected with other type of high risk HPV which can lead to cervical cancer and cannot prevented by currently available vaccines. In addition to HPV 16 and/or 18, most common types of high risk HPV were types 58, 52, 35 and 45. Awareness about HPV and HPV vaccines was still low in the study samples.DiscussionWhile it is relevant to implement an HPV vaccine campaign in Viet Nam, it is important to note that one can be infected with multiple types of HPV. Vaccination does not protected against all type of high risk HPV types. Future vaccine campaigns should openly disclose this information to women receiving vaccines.ConclusionHigh prevalence of infection with HPV high risk types was observed in this study. As HPV infection has a high correlation with cervical cancer, this study emphasizes the need for both primary prevention of cervical cancer with HPV vaccines as well as secondary prevention with screening.
We have developed a cryogenic twodimensional magnetic imaging system that incorporates a sensitive dc SQUID detector. In this instrument. which we call the Scanning SQUID Microscope (SSM). a flux transformer coupled to the SQUID is scanned over the surface of a planar sample by a room temperature. stepping motorcontrolled manipulator with a positional resolution of about 2pm. With our present input coil. spatial resolution of 2Opm and a flux sensitivity at the sample of 10-5@o/Hz1r-is attainable. This system has been specifically designed to image the vortex structure and dynamics of weakly-coupled superconductor arrays.
This study examined factors that contributed to the success of online learners in an online professional development course. Research instruments included an online survey and learners' activity logs in an online professional development course for 512 in-service teachers. The findings showed that there were several factors affecting online learners' success in online professional development. In addition, there were also significant differences between successful and unsuccessful online learners in terms of course login frequency and learning activities viewed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.