Bare overhead distribution conductors are typically flexible and uniform in weight along their lengths. This weight causes the span to form a catenary (sag) which changes with conductor temperature, ice, wind loading and time. This catenary is capable of tripping circuits because it often results to short circuit and damage power system equipment with attendant loss of revenue to utility company. This paper presents a case study of 33kV overhead line construction crossing a 200m wide 'Lagoon' which requires minimum sag-tension design and estimation of Dead-End Lattice Tower weight specification that would determine weight of Tower foundation. These two parameters were obtained using the standard mathematical equations and the specifications for Aluminium Conductor Steel Reinforce (ACSR). The results of various Parameters evaluated in this research work are presented and discussed. The Sag and Tower weight results were applied to the proposed project which was successfully completed and commissioned.
Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which generate harmonics in a power system and this has a cumulative negative effect on power quality. Examples of
Engineers and planners have realized that equipment grounding is a necessary part of installation process in Electrical power substations. Over years, grounding or earthing has been carried out primarily through preparation of Earth Mat which is interconnected with several Earth-rods buried around the equipment under consideration. This approach takes several efforts to have an acceptable and reliable result. However, this paper presents a more flexible, economical and results oriented approach. A flow chart which describes the procedures of carrying out the proposed method of earthing is developed. This was applied to two case studies: a proposed Power transformer substation and distribution Transformer substation located within the same geographical domain. On the two cases, the measured earth resistances are presented and discussed. The results from the case study indicates that the earth resistance values obtained from this new approach are reliable and in compliance with IEEE Standards 80,142, 81 and 1100.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.