Determination of Total Harmonic Distortion (THD) on a 33kv Distribution Network: A Case Study of Island Business District

Abstract: Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which Modern day AC power systems are proliferated by the introduction of several kinds of nonlinear loads which generate harmonics in a power system and this has a cumulative negative effect on power… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…The newly constructed lines T-off near a 15MVA 33/11kV injection substation. Thus, when the newly constructed 1MVA 33/0.415kV substation is finally energized, the load will be operating an approximate short distance of 265m which will definitely measure lower value of Total harmonic distortion [12] which automatically leads to reduction in Technical losses [13]. Hence, marginal cost of Transmission or Distribution expansion is achieved [14].…”
Section: Resultsmentioning
confidence: 99%
“…The newly constructed lines T-off near a 15MVA 33/11kV injection substation. Thus, when the newly constructed 1MVA 33/0.415kV substation is finally energized, the load will be operating an approximate short distance of 265m which will definitely measure lower value of Total harmonic distortion [12] which automatically leads to reduction in Technical losses [13]. Hence, marginal cost of Transmission or Distribution expansion is achieved [14].…”
Section: Resultsmentioning
confidence: 99%
“…This means estimation of harmonics is of high importance for purpose of efficiency for power system network. (Kumar, Bhunesh, 2011) Harmonics data contains Amplitude, Phase Angle and Inter-harmonics Amplitude of both current and voltage captured separately on a ten-minute interval daily for the three phase lines referred to as; (L. M. Adesina & O. A. Fakolujo, 2015) Continuous Fourier transform given as:…”
Section: Methodsmentioning
confidence: 99%