Time has always had a special status in physics because of its fundamental role in specifying the regularities of nature and because of the extraordinary precision with which it can be measured. This precision enables tests of fundamental physics and cosmology, as well as practical applications such as satellite navigation. Recently, a regime of operation for atomic clocks based on optical transitions has become possible, promising even higher performance. We report the frequency ratio of two optical atomic clocks with a fractional uncertainty of 5.2 x 10(-17). The ratio of aluminum and mercury single-ion optical clock frequencies nuAl+/nuHg+ is 1.052871833148990438(55), where the uncertainty comprises a statistical measurement uncertainty of 4.3 x 10(-17), and systematic uncertainties of 1.9 x 10(-17) and 2.3 x 10(-17) in the mercury and aluminum frequency standards, respectively. Repeated measurements during the past year yield a preliminary constraint on the temporal variation of the fine-structure constant alpha of alpha/alpha = (-1.6+/-2.3) x 10(-17)/year.
Progress in realizing the SI second had multiple technological impacts and enabled further constraint of theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4 Â 10 À 16 , have already been overtaken by atomic clocks referenced to an optical transition, which are both more stable and more accurate. Here we present an important step in the direction of a possible new definition of the second. Our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.5 Â 10 À 16 . Their comparison with three independent caesium fountains shows a degree of accuracy now only limited by the best realizations of the microwave-defined second, at the level of 3.1 Â 10 À 16 .
We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5×10(-17) after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10(-17) level, even for lattices as deep as 150 recoil energies.
(PTB) operate cold-atom based primary frequency standards which are capable of realizing the SI second with a relative uncertainty of 1 × 10 −15 or even below. These institutes performed an intense comparison campaign of selected frequency references maintained in their laboratories during about 25 days in October/November 2004. Active hydrogen maser reference standards served as frequency references for the institutes' fountain frequency standards. Three techniques of frequency (and time) comparisons were employed. Two-way satellite time and frequency transfer (TWSTFT) was performed in an intensified measurement schedule of 12 equally spaced measurements per day. The data of dual-frequency geodetic Global Positioning System (GPS) receivers were processed to yield an ionosphere-free linear combination of the code observations from both GPS frequencies, typically referred to as GPS TAI P3 analysis. Last but not least, the same GPS raw data were separately processed, allowing GPS carrier-phase (GPS CP) based frequency comparisons to be made. These showed the lowest relative frequency instability at short averaging times of all the methods. The instability was at the level of 1 part in 10 15 at one-day averaging time using TWSTFT and GPS CP. The GPS TAI P3 analysis is capable of giving a similar quality of data after averaging over two days or longer. All techniques provided the same mean frequency difference between the standards involved within the 1σ measurement uncertainty of a few parts in 10 16. The frequency differences between the three fountains of IEN (IEN-CsF1), NPL (NPL-CsF1) and OP (OP-FO2) were evaluated. Differences lower than the 1σ measurement uncertainty were observed between NPL and OP, whereas the IEN fountain deviated by about 2σ from the other two fountains.
We report tests of local position invariance and the variation of fundamental constants from measurements of the frequency ratio of the 282-nm 199Hg+ optical clock transition to the ground state hyperfine splitting in 133Cs. Analysis of the frequency ratio of the two clocks, extending over 6 yr at NIST, is used to place a limit on its fractional variation of <5.8x10(-6) per change in normalized solar gravitational potential. The same frequency ratio is also used to obtain 20-fold improvement over previous limits on the fractional variation of the fine structure constant of |alpha/alpha|<1.3x10(-16) yr-1, assuming invariance of other fundamental constants. Comparisons of our results with those previously reported for the absolute optical frequency measurements in H and 171Yb+ vs other 133Cs standards yield a coupled constraint of -1.5x10(-15)
Recent developments in stabilized lasers have resulted in ultrastable optical oscillators with spectral purities below 1 Hz refs 1 - 6. These oscillators are not transportable at present and operate at a single frequency. To realize their full potential, a highly coherent, frequency-diverse fibre-optic network is needed to faithfully transfer the optical signals to remote sites and to different optical frequencies. Here we demonstrate such a coherent network composed of erbium fibre and Ti: sapphire laser-based, optical-frequency combs(7-9), stabilized optical-fibre links(4,10) and cavity-stabilized lasers(4-6). We coherently transmit an optical carrier over 750 m of optical fibre with conversions to wavelengths of 657, 767, 1,126 and 1,535 nm, an overall timing jitter of 590 attoseconds, and a frequency instability of 12 mHz for the 195 THz carrier in 1 s and 250 mu Hz in 1,000 s. This first remote synchronization of two frequency combs also demonstrates a factor of 30 improvement in the relative stability of fibre frequency combs(11,12)
Abstract-We report on the observation of a dc Stark frequency shift at the 10 −13 level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residual dc Stark frequency shift on the clock transition at the 10 −18 level by applying an external electric field. This study shows that the dc Stark shift can play an important role in the accuracy budget of lattice clocks, and should be duly taken into account.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.