The observed differences in the biomechanical response of normal and glaucoma sclera may represent baseline properties that contribute to axon damage, or may be characteristics that result from glaucomatous disease.
Solid electrolytes are crucial for the development of solid state batteries. Among different types of solid electrolytes, poly(ethylene oxide) (PEO)-based polymer electrolytes have attracted extensive attention owing to their excellent flexibility and easiness for processing. However, their relatively low ionic conductivities and electrochemical instability above 4 V limit their applications in batteries with high energy density. Herein, we prepared poly(vinylidene fluoride) (PVDF) polymer electrolytes with an organic plasticizer, which possesses compatibility with 4 V cathode and high ionic conductivity (1.2 × 10 S/cm) at room temperature. We also revealed the importance of plasticizer content to the ionic conductivity. To address weak mechanical strength of the PVDF electrolyte with plasticizer, we introduced palygorskite ((Mg,Al)SiO(OH)) nanowires as a new ceramic filler to form composite solid electrolytes (CPE), which greatly enhances both stiffness and toughness of PVDF-based polymer electrolyte. With 5 wt % of palygorskite nanowires, not only does the elastic modulus of PVDF CPE increase from 9.0 to 96 MPa but also its yield stress is enhanced by 200%. Moreover, numerical modeling uncovers that the strong nanowire-polymer interaction and cross-linking network of nanowires are responsible for such significant enhancement in mechanically robustness. The addition of 5% palygorskite nanowires also enhances transference number of Li from 0.21 to 0.54 due to interaction between palygorskite and ClO ions. We further demonstrate full cells based on Li(NiMnCo)O (NMC111) cathode, PVDF/palygorskite CPE, and lithium anode, which can be cycled over 200 times at 0.3 C, with 97% capacity retention. Moreover, the PVDF matrix is much less flammable than PEO electrolytes. Our work illustrates that the PVDF/palygorskite CPE is a promising electrolyte for solid state batteries.
Appropriate mechanical function of the uterine cervix is critical for maintaining a pregnancy to term so that the fetus can develop fully. At the end of pregnancy, however, the cervix must allow delivery, which requires it to markedly soften, shorten and dilate. There are multiple pathways to spontaneous preterm birth, the leading global cause of death in children less than 5 years old, but all culminate in premature cervical change, because that is the last step in the final common pathway to delivery. The mechanisms underlying premature cervical change in pregnancy are poorly understood, and therefore current clinical protocols to assess preterm birth risk are limited to surrogate markers of mechanical function, such as sonographically measured cervical length. This is what motivates us to study the cervix, for which we propose investigating clinical cervical function in parallel with a quantitative engineering evaluation of its structural function. We aspire to develop a common translational language, as well as generate a rigorous integrated clinical-engineering framework for assessing cervical mechanical function at the cellular to organ level. In this review, we embark on that challenge by describing the current landscape of clinical, biochemical, and engineering concepts associated with the mechanical function of the cervix during pregnancy. Our goal is to use this common platform to inspire novel approaches to delineation of normal and abnormal cervical function in pregnancy.
The exponential rise in genomics research over the past decade has yielded a growing number of sequence variants associated with medication response that may have clinical utility. Despite existing barriers, attention is turning to strategies that integrate these data into clinical care. The CLIPMERGE PGx Program is establishing a best‐practices infrastructure for the implementation of genome‐informed prescribing using a biobank‐derived clinical cohort, preemptive genetic testing, and real‐time clinical decision support deployed through the electronic health record.
Clinical Pharmacology & Therapeutics (2013); 94 2, 214–217. doi:
The changes in the mechanical integrity of the cervix during pregnancy have implications for a successful delivery. Cervical collagens are known to remodel extensively in mice with progressing gestation leading to a soft cervix at term. During this process, mature crosslinked collagens are hypothesized to be replaced with immature less crosslinked collagens to facilitate cervical softening and ripening. To determine the mechanical role of collagen crosslinks during normal mouse cervical remodeling, tensile load-to-break tests were conducted for the following time points: nonpregnant (NP), gestation day (d) 6, 12, 15, 18 and 24 hr postpartum (PP) of the 19-day gestation period. Immature crosslinks (HLNL and DHLNL) and mature crosslinks (DPD and PYD) were measured using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS). There were no significant changes in the total immature crosslink density (HLNL+DHLNL mol per collagen mol) throughout normal mouse gestation (range: 0.31–0.49). Total mature crosslink density (PYD+DPD mol per collagen mol) decreased significantly in early softening from d6 to d15 (d6: 0.17, d12: 0.097, d15: 0.026) and did not decrease with further gestation. The maturity ratio (total mature to total immature crosslinks) significantly decreased in early softening from d6 to d15 (d6: 0.2, d15: 0.074). All of the measured crosslinks correlated significantly with a measure of tissue stiffness and strength, with the exception of the immature crosslink HLNL. This data provides quantitative evidence to support the hypothesis that as mature crosslinked collagens decline, they are replaced by immature collagens to facilitate increased tissue compliance in the early softening period from d6 to d15.
The cervix plays a crucial role in maintaining a healthy pregnancy, acting as a mechanical barrier to hold the fetus in utero during gestation. Altered mechanical properties of the cervical tissue are suspected to play a critical role in spontaneous preterm birth. Both MRI and X-ray data in the literature indicate that cervical stroma contains regions of preferentially aligned collagen fibers along anatomical directions (circumferential/longitudinal/radial). In this study, a mechanical testing protocol is developed to investigate the large-strain response of cervical tissue in uniaxial tension and compression along its three orthogonal anatomical directions. The stress response of the tissue along the different orthogonal directions is captured using a minimal set of model parameters generated by fitting a one-dimensional time-dependent rheological model to the experimental data. Using model parameters, mechanical responses can be compared between samples from patients with different obstetric backgrounds, between samples from different anatomical sites, and between the different loading directions for a single specimen. The results presented in this study suggest that cervical tissue is mechanically anisotropic with a uniaxial response dependent on the direction of loading, the anatomical site of the specimen, and the obstetric history of the patient. We hypothesize that the directionality of the tissue mechanical response is primarily due to collagen orientation in the cervical stroma, and provides an interpretation of our mechanical findings consistent with the literature data on preferential collagen alignment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.