Various treatment methods are available for the treatment of varicose veins, and there has been a recent surge in the usage of cyanoacrylate glue for treating varicose veins. Purpose To investigate the technical possibility, efficiency and safety of cyanoacrylate adhesive embolization and sclerotherapy using commonly available n-butyl cyanoacrylate glue for the treatment of primary varicose veins due to great saphenous vein reflux with or without incompetent perforators. Materials and Methods One hundred forty-five limbs of 124 patients with varicose veins due to great saphenous vein reflux were subjected to cyanoacrylate adhesive embolization and sclerotherapy - adhesive embolization of great saphenous vein in the thigh and perforators using cyanoacrylate followed by sclerotherapy of any residual varicose veins in the leg. Procedural success, venous closure rates and clinical improvement were assessed. Follow-up for 1, 3, 6, 9 and 12 months was obtained. Results Technical success rate was 100%. Saphenous vein closure rate was 96.5% at one year. There was no femoral venous extension of cyanoacrylate in any of the patients. Posterior tibial vein extension of cyanoacrylate was seen in three patients (2.6%) without untoward clinical effect.Significant improvement was found in venous clinical severity score (VCSS) from a baseline mean of 7.98 ± 4.42 to 4.74 ± 3, 1.36 ± 1.65 and 0.79 ± 1.19 at 1, 6 and 12 months' follow-up. Ulcer healing rate was 100%. Conclusion Cyanoacrylate adhesive embolization and sclerotherapy for the treatment of primary varicose veins is efficacious and can be performed as an outpatient procedure, but has a guarded safety profile due to its propensity to cause deep venous occlusion if not handled carefully.
pCONus is a stent-like endovascular device which aids in retention of coils within wide-necked bifurcation aneurysms. It is retrievable even after complete deployment and is detached electrolytically. The pCONus aided coiling of wide-necked bifurcation aneurysms has a high technical success rate and a good safety profile. Different complications have been described in literature with the usage of pCONus. This case report describes a unreported complication of inappropriately deployed pCONus device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.