Background Pathogenic genetic testing for coronavirus disease 2019 (COVID-19) can detect viruses with high sensitivity; however, there are several challenges. In the prevention, testing, and treatment of COVID-19, more effective, safer, and convenient methods are desired. We evaluated the possibility of monocyte distribution width (MDW) as an infection biomarker in COVID-19 testing. Methods The efficacy of MDW as a screening test for COVID-19 was retrospectively assessed in 80 patients in the COVID-19 group and 232 patients in the non-COVID-19 group (141 patients with acute respiratory infection, 19 patients with nonrespiratory infection, one patient with a viral infection, 11 patients who had received treatment for COVID-19, one patient in contact with COVID-19 patients, and 59 patients with noninfectious disease). Results The median MDW in 80 patients in the COVID-19 group was 23.3 (17.2–33.6), and the median MDW in 232 patients in the non-COVID-19 group was 19.0 (13.6–30.2) (P < 0.001). When the COVID-19 group was identified using the MDW cut-off value of 21.3 from the non-COVID-19 group, the area under the curve (AUC) was 0.844, and the sensitivity and specificity were 81.3% and 78.2%, respectively. Comparison of MDW by severity between the COVID-19 group and patients with acute respiratory infection in the non-COVID-19 group showed that MDW was significantly higher in the COVID-19 group for all mild, moderate I, and moderate II disease. Conclusions MDW (cut-off value: 21.3) may be used as a screening test for COVID-19 in fever outpatients. Trial registration This study was conducted after being approved by the ethics committee of National Hospital Organization Omuta National Hospital (Approval No. 3-19). This study can be accessed via https://omuta.hosp.go.jp/files/000179721.pdf.
Purpose: Pathogenic genetic testing for Coronavirus disease 2019 (COVID-19) can detect viruses with high sensitivity, however there are several challenges. In the prevention, testing, and treatment of COVID-19, more effective, safer, and convenient methods are desired. We evaluated the possibility of monocyte distribution width (MDW) as an infection biomarker in COVID-19 testing.Methods: The efficacy of MDW as a screening test for COVID-19 was retrospectively assessed in 80 patients in the COVID-19 group and 232 patients in the Non-COVID-19 group (141 patients with acute respiratory infection, 19 patients with non-respiratory infection, 1 patient with viral infection, 11 patients who had received treatment for COVID-19, 1 patient in contact with COVID-19 patients, and 59 patients with non-infectious disease). Results: The median MDW in 80 patients in the COVID-19 group was 23.3 (17.2-33.6), and the median MDW in 232 patients in the Non-COVID-19 group was 19.0 (13.6-30.2) (P < 0.001). When the COVID-19 group was identified using the MDW cut-off value of 21.3 from the Non-COVID-19 group, the area under the curve (AUC) was 0.844, and the sensitivity and specificity were 81.3% and 78.2%, respectively. Comparison of MDW by severity between the COVID-19 group and patients with acute respiratory infection in the Non-COVID-19 group showed that MDW was significantly higher in the COVID-19 group for all of mild, moderate I, and moderate II disease. Conclusions: MDW (cut-off value: 21.3) may be used as a screening test for COVID-19 in fever outpatients, etc.
Background Pathogenic genetic testing for Coronavirus disease 2019 (COVID-19) can detect viruses with high sensitivity, however there are several challenges. In the prevention, testing, and treatment of COVID-19, more effective, safer, and convenient methods are desired. We evaluated the possibility of monocyte distribution width (MDW) as an infection biomarker in COVID-19 testing. Methods The efficacy of MDW as a screening test for COVID-19 was retrospectively assessed in 80 patients in the COVID-19 group and 232 patients in the Non-COVID-19 group (141 patients with acute respiratory infection, 19 patients with non-respiratory infection, 1 patient with viral infection, 11 patients who had received treatment for COVID-19, 1 patient in contact with COVID-19 patients, and 59 patients with non-infectious disease). Results The median MDW in 80 patients in the COVID-19 group was 23.3 (17.2–33.6), and the median MDW in 232 patients in the Non-COVID-19 group was 19.0 (13.6–30.2) (P < 0.001). When the COVID-19 group was identified using the MDW cut-off value of 21.3 from the Non-COVID-19 group, the area under the curve (AUC) was 0.844, and the sensitivity and specificity were 81.3% and 78.2%, respectively. Comparison of MDW by severity between the COVID-19 group and patients with acute respiratory infection in the Non-COVID-19 group showed that MDW was significantly higher in the COVID-19 group for all of mild, moderate I, and moderate II disease. Conclusions MDW (cut-off value: 21.3) may be used as a screening test for COVID-19 in fever outpatients, etc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.