Background-Contrast agents can cause a reduction in renal function that may be due to the generation of reactive oxygen species. Conflicting evidence suggests that administration of the antioxidant acetylcysteine prevents this renal impairment. The action of other antioxidant agents has not been investigated. Methods and Results-We conducted a randomized, double-blind, placebo-controlled trial of ascorbic acid in 231 patients with a serum creatinine concentration Ն1.2 mg/dL who underwent coronary angiography and/or intervention. Ascorbic acid, 3 g at least 2 hours before the procedure and 2 g in the night and the morning after the procedure, or placebo was administered orally. Contrast-mediated nephropathy was defined by an absolute increase of serum creatinine Ն0.5 mg/dL or a relative increase of Ն25% measured 2 to 5 days after the procedure.
TMVR with the valve was feasible in a study group at high or extreme risk for conventional mitral valve replacement. These results inform trial design of TMVR in lower-risk patients with severe mitral valve regurgitation (Evaluation of the Safety and Performance of the Twelve Intrepid Transcatheter Mitral Valve Replacement System in High Risk Patients with Severe, Symptomatic Mitral Regurgitation - The Twelve Intrepid TMVR Pilot Study; NCT02322840).
TAVR using the next-generation THV is clinically safe and effective for treating older patients with severe AS at increased operative risk. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369).
Aims
Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV.
Methods and results
A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2–12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02–1.13)], age [HR 1.21 (95% CI 1.01–1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11–1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis–patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31–14.39)], device malposition [SHR 3.75 (95% CI 1.36–10.35)], EBEV [SHR 3.34 (95% CI 1.26–8.85)], and age [SHR 0.59 (95% CI 0.44–0.78)].
Conclusions
The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.