Pathological abnormality of the peroneal tendons is an under-appreciated source of lateral hindfoot pain and dysfunction that can be difficult to distinguish from lateral ankle ligament injuries.Enclosed within the lateral compartment of the leg, the peroneal tendons are the primary evertors of the foot and function as lateral ankle stabilisers.Pathology of the tendons falls into three broad categories: tendinitis and tenosynovitis, tendon subluxation and dislocation, and tendon splits and tears. These can be associated with ankle instability, hindfoot deformity and anomalous anatomy such as a low lying peroneus brevis or peroneus quartus.A thorough clinical examination should include an assessment of foot type (cavus or planovalgus), palpation of the peronei in the retromalleolar groove on resisted ankle dorsiflexion and eversion as well as testing of lateral ankle ligaments.Imaging including radiographs, ultrasound and MRI will help determine the diagnosis. Treatment recommendations for these disorders are primarily based on case series and expert opinion.The aim of this review is to summarise the current understanding of the anatomy and diagnostic evaluation of the peroneal tendons, and to present both conservative and operative management options of peroneal tendon lesions.Cite this article: EFORT Open Rev 2017;2:281-292. DOI: 10.1302/2058-5241.2.160047
Background Many impinging hips are said to have a mix of features of femoral cam and an overcovered acetabulum causing pincer impingement. Correction of such a mixed picture by reduction of the cam lesion and the acetabular rim is the suggested treatment. Questions/purposes We therefore asked two questions: (1) Is the acetabulum in cam impingement easily distinguishable from the pincer acetabulum, or is there a group with features of both types of impingement? (2) Is version or depth of socket better able to distinguish cam from pincer impingement? Methods We analyzed the morphologic features of the acetabulum and rim profile of 20 normal, healthy hips, 20 with cams and 20 with pincers on CT. Pelvises were digitized, orientated to the best-fit acetabular plane, and a rim profile was plotted. Results Cam hips were shallower than normal hips, which in turn were shallower than pincer hips (84°± 5°v ersus 87°± 4°versus 96°± 5°, respectively). The rim planes of cam, normal, and pincer hips had similar version (23°, 24°, 25°), but females were 4°more anteverted than males.
ConclusionsWe concluded cam and pincer hips are distinct pathoanatomic entities. Cam hips are slightly shallower than normal, whereas pincers are deeper. Clinical Relevance Before performing surgery for camtype femoroacetabular impingement, surgeons should consider measuring the acetabular depth. The cam acetabulum is shallower than normal and may be rendered pathologically shallow by acetabular rim resection leading to early joint failure.
We retrospectively analysed concentrations of chromium and cobalt ions in samples of synovial fluid and whole blood taken from a group of 92 patients with failed current-generation metal-on-metal hip replacements. We applied acid oxidative digestion to our trace metal analysis protocol, which found significantly higher levels of metal ion concentrations in blood and synovial fluid than a non-digestive method. Patients were subcategorised by mode of failure as either 'unexplained pain' or 'defined causes'. Using this classification, chromium and cobalt ion levels were present over a wider range in synovial fluid and not as strongly correlated with blood ion levels as previously reported. There was no significant difference between metal ion concentrations and manufacturer of the implant, nor femoral head size below or above 50 mm. There was a moderately positive correlation between metal ion levels and acetabular component inclination angle as measured on three-dimensional CT imaging. Our results suggest that acid digestion of samples of synovial fluid samples is necessary to determine metal ion concentrations accurately so that meaningful comparisons can be made between studies.
Single-photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) is an emerging technology that may hold great clinical value to the orthopaedic knee surgeon. Post-operative knee pain is a familiar condition seen in most orthopaedic clinics. Here, we present the value of SPECT/CT in three such cases of pain after surgical treatment of knee osteoarthritis (high tibial osteotomy, medial unicompartmental arthroplasty, total knee arthroplasty). In these patients with post-operative knee pain, SPECT/CT has proved to be beneficial in establishing the diagnosis and providing guidance for further treatment.
Integrated hybrid single photon emission computerized tomography (SPECT)/computer tomography (CT) is a promising new diagnostic imaging modality for orthopedic patients. A high diagnostic yield is available from combining the detection of abnormal bone metabolism with SPECT, to the precise anatomical detail available in high resolution CT. With this review, we endeavor to illustrate the clinical value and future perspectives of SPECT/CT in sports medicine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.