The present study describes a simple, reliable and reproducible liquid chromatography–tandem mass spectrometry method (LC–MS/MS) for the simultaneous determination of allopurinol and its active metabolite, oxypurinol in human plasma for a pharmacokinetic/bioequivalence study. After protein precipitation (PPT) of 100 µL plasma sample with 1.0% formic acid in acetonitrile, the recovery of the analytes and allopurinol-d2 as an internal standard ranged from 85.36% to 91.20%. The analytes were separated on Hypersil Gold (150 mm×4.6 mm, 5 µm) column using 0.1% formic acid-acetonitrile (98:2, v/v) as the mobile phase. Quantification was done using electrospray ionization in the positive mode. The calibration concentration range was established from 60.0 to 6000 ng/mL for allopurinol and 80.0–8000 ng/mL for oxypurinol. Matrix effect in human plasma, expressed as IS-normalized matrix factors ranged from 1.003 to 1.030 for both the analytes. The developed method was found suitable for a clinical study with 300 mg allopurinol tablet formulation in healthy subjects.
An improved high performance liquid chromatography--tandem mass spectrometry (LC–MS/MS) method has been developed for sensitive and rapid determination of albendazole (ABZ) and its active metabolite, albendazole sulfoxide (ABZSO), in the positive ionization mode. The method utilized solid phase extraction (SPE) for sample preparation of the analytes and their deuterated internal standards (ISs) from 100 µL human plasma. The chromatography was carried out on Hypurity C18 column using acetonitrile-2.0 mM ammonium acetate, pH 5.0 (80:20, v/v) as the mobile phase. The assay exhibited a linear response over the concentration range of 0.200–50.0 ng/mL for ABZ and 3.00–600 ng/mL for ABZSO. The recoveries of the analytes and ISs ranged from 86.03%–89.66% and 89.85%–98.94%, respectively. Matrix effect, expressed as IS-normalized matrix factors, ranged from 0.985 to 1.042 for the both analytes. The method was successfully applied for two separate studies in healthy subjects using single dose of 400 mg conventional tablets and 400 mg chewable ABZ tablets, respectively.
A highly sensitive and selective high performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of alverine (ALV) and its active metabolite, para hydroxy alverine (PHA), in human plasma. For sample preparation, solid phase extraction of analytes was performed on Phenomenex Strata-X cartridges using alverine-d5 as the internal standard. The analytes were separated on Symmetry Shield RP18 (150 mm×3.9 mm, 5 µm) column with a mobile phase consisting of acetonitrile and 10 mM ammonium formate (65:35, v/v). Detection and quantitation was done by electrospray ionization mass spectrometry in the positive mode using multiple reaction monitoring. The assay method was fully validated over the concentration range of 15.0–15,000 pg/mL for ALV and 30.0–15,000 pg/mL for PHA. The intra-day and inter-day accuracy and precision (% CV) ranged from 94.00% to 96.00% and 0.48% to 4.15% for both the analytes. The mean recovery obtained for ALV and PHA was 80.59% and 81.26%, respectively. Matrix effect, expressed as IS-normalized matrix factor ranged from 0.982 to 1.009 for both the analytes. The application of the method was demonstrated for the specific analysis of ALV and PHA for a bioequivalence study in 52 healthy subjects using 120 mg ALV capsules. The assay reproducibility was also verified by reanalysis of 175 incurred subject samples.
Although studies of charged hydrogel swelling focus on the swelling transition, hydrogels display pre-transition swelling which may affect their performance in applications such as sensors. In this paper we investigate the effect of system parameters on the pre-transition swelling of charged poly methacrylic acid (PMAA) hydrogels. We find that the pre-transition swelling can be quite significant in magnitude (in our case 40% of the maximal swelling). Increasing the sub-chain molecular weight increases swelling in the pre-transition region only in the case where no salt is added; Contrary to expectation, in moderate ionic strength solutions the degree of swelling of longer chains is lower than that of shorter sub-chains. Also contrary to expectation, in the case of longer sub-chains the addition of salt decreases the gel volume in the pre-transition region, thereby indicating that in this system a significant number of charges are dissociated. These trends can be understood by accounting for the combined effect of pH and the ionic strength on the degree of charge dissociation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.