BackgroundSystemic blood flow in patients on extracorporeal assist devices is frequently not or only minimally pulsatile. Loss of pulsatile brain perfusion, however, has been implicated in neurological complications. Furthermore, the adverse effects of absent pulsatility on the cerebral microcirculation are modulated similarly as CO2 vasoreactivity in resistance vessels. During support with an extracorporeal assist device swings in arterial carbon dioxide partial pressures (PaCO2) that determine cerebral oxygen delivery are not uncommon—especially when CO2 is eliminated by the respirator as well as via the gas exchanger of an extracorporeal membrane oxygenation machine. We, therefore, investigated whether non-pulsatile flow affects cerebrovascular CO2 reactivity (CVR) and regional brain oxygenation (rSO2).MethodsIn this prospective, single-centre case-control trial, we studied 32 patients undergoing elective cardiac surgery. Blood flow velocity in the middle cerebral artery (MCAv) as well as rSO2 was determined during step changes of PaCO2 between 30, 40, and 50 mmHg. Measurements were conducted on cardiopulmonary bypass during non-pulsatile and postoperatively under pulsatile blood flow at comparable test conditions. Corresponding changes of CVR and concomitant rSO2 alterations were determined for each flow mode. Each patient served as her own control.ResultsMCAv was generally lower during hypocapnia than during normocapnia and hypercapnia (p < 0.0001). However, the MCAv/PaCO2 slope during non-pulsatile flow was 14.4 cm/s/mmHg [CI 11.8–16.9] and 10.4 cm/s/mmHg [CI 7.9–13.0] after return of pulsatility (p = 0.03). During hypocapnia, non-pulsatile CVR (4.3 ± 1.7%/mmHg) was higher than pulsatile CVR (3.1 ± 1.3%/mmHg, p = 0.01). Independent of the flow mode, we observed a decline in rSO2 during hypocapnia and a corresponding rise during hypercapnia (p < 0.0001). However, the relationship between ΔrSO2 and ΔMCAv was less pronounced during non-pulsatile flow.ConclusionsNon-pulsatile perfusion is associated with enhanced cerebrovascular CVR resulting in greater relative decreases of cerebral blood flow during hypocapnia. Heterogenic microvascular perfusion may account for the attenuated ΔrSO2/ΔMCAv slope. Potential hazards related to this altered regulation of cerebral perfusion still need to be assessed.Trial registrationThe study was retrospectively registered on October 30, 2018, with Clinical Trial.gov (NCT03732651).
Aims
Surgical site infections contribute to morbidity and mortality after surgery. The authors hypothesized that higher antibiotic tissue concentrations can be reached for a prolonged time span by continuous administration of prophylactic cefuroxime compared to bolus administration.
Methods
Twelve patients undergoing elective cardiac surgery were investigated. Group A received 1.5 g cefuroxime as bolus infusions before surgery, and 12 and 24 hours thereafter. In group B, a continuous infusion of 3.0 g cefuroxime was started after a bolus of 1.5 g. Cefuroxim levels were determined in blood and tissue (microdialysis). T‐test, Wilcoxon signed rank test and χ2 test were used for statistical analysis.
Results
The area under the curve (AUC) of plasma cefuroxime concentrations was greater in group B (399 [333–518]) as compared to group A (257 [177–297] h mg L−1, [median and interquartile range], P = .026). Furthermore, a significantly longer percentage of time > minimal inhibitory concentrations of 2 mg L−1 (100% vs 50%), 4 mg L−1 (100% vs 42%), 8 mg L−1 (100% vs 17%) and 16 mg L−1 (83% vs 8%) was found for free plasma cefuroxime in group B. In group B, area under the curve in subcutaneous tissue (78 [61–113] h mg L−1) and median peak concentration (33 [26–38] mg L−1) were markedly higher compared to group A (P = 0.041 and P = .026, respectively).
Conclusions
Higher cefuroxime concentrations were measured in plasma and subcutaneously over a prolonged period of time when cefuroxime was administered continuously. The clinical implication of this finding still has to be elucidated.
Cerebral oximetry is a Food and Drug Administration-approved technology that allows monitoring of brain oxygen saturation in accessible superficial brain cortex regions, which are amongst the most vulnerable in regard to ischemic or hypoxic injury. Since most oxygen in the area of interest is located in the venous compartment, the determined regional brain oxygen saturation approximately reflects the local balance between oxygen delivery and oxygen consumption. Major systemic alterations in blood oxygen content and oxygen delivery will be accompanied by corresponding changes in regional brain saturation. This systematic review, which is based on a Medline search, focuses on the characteristic changes in regional cerebral oxygen saturation that occur, when global oxygen supply to the brain ceases. It further highlights the potential application of cerebral oximetry in the management of cardiac arrest victims, the predictability of clinical outcome after global cerebral ischemia, and it also indicates possible potentials for the management of cerebral reperfusion after having instituted return of spontaneous circulation.
Background: Mechanical circulatory support (MCS) in pediatric patients remains challenging because of small body size, limited availability of approved devices, and the variety of etiologies, including biventricular and univentricular physiologies. We report our single-center experience with MCS in pediatric patients in terms of survival and adverse events.Methods: Outcome, etiologic, and demographic data of pediatric patients implanted with a long-term MCS device between 2011 and 2019 at the Medical University of Vienna were retrospectively collected and analyzed. Overall survival and freedom of treatment-related adverse events at 1 year were investigated by Kaplan-Meier analyses and stratified for circulation (biventricular vs univentricular), age group (<6 years vs>6 years), and pump technology (pulsatile ventricular assist device [p-VAD] vs continuous flow pump [cf-VAD]).Results: One-year survival of all 33 pediatric patients (median, 4 years; interquartile range, 0-13 years) was 73%, with a tendency toward better outcomes in patients with biventricular circulation than in those with univentricular circulation (80%; n ¼ 25 vs 50%; n ¼ 8; P ¼ .063). The trends toward better survival probability in older patients and in patients with cf-VADs did not reach statistical significance (63.2% vs 85.7%; P ¼ .165 and 82.4% vs 62.5%; P ¼ .179, respectively). Freedom from adverse events was higher in older patients (57.1% vs 5.6%; P < .001) and in the cf-VAD group (52.9% vs 0%; P < .001), with pump thrombosis as the main discriminator.Conclusions: MCS is a promising therapy for a broad spectrum of pediatric patients, irrespective of heart failure etiology, age, and pump type. With increasing experience, improved devices, and patient selection, MCS may become a valuable treatment option for patients with univentricular hearts. (JTCVS Open
Regional cerebral tissue saturation monitoring is frequently used in patients on mechanical cardiac assist devices with the intention to promptly detect critical imbalances between cerebral oxygen delivery and oxygen extraction and ultimately circumvent permanent brain injury. We report a case where an intraparenchymal bleed in the supply zone of the middle cerebral artery—followed by severe hemispherical brain edema, leading to life-threatening intracranial hypertension—escaped cerebral oximetry monitoring using near-infrared spectroscopy. Potential explanations for our observation, as well as the specific limitations of these devices, are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.