This tutorial review will introduce and explore the fundamental aspects of nanopore (bio)sensing, fabrication, modification, and the emerging technologies and applications that both intrigue and inspire those working in and around the field. Although nanopores can be classified into two categories, solid-state and biological, they are essentially two sides of the same coin. For instance, both garner popularity due to their ability to confine analytes of interest to a nanoscale volume. Due to the vast diversity of nanopore platforms and applications, no single review can cover the entire landscape of published work in the field. Therefore, in this article focus will be placed on recent advancements and developments taking place in the field of solid-state nanopores. It should be stated that the intention of this tutorial review is not to cite all articles relating to solid-state nanopores, but rather to highlight recent, select developments that will hopefully benefit the new and seasoned scientist alike. Initially we begin with the fundamentals of solid-state nanopore sensing. Then the spotlight is shone on the sophisticated fabrication methods that have their origins in the semiconductor industry. One inherent advantage of solid-state nanopores is in the ease of functionalizing the surface with a range of molecules carrying functional groups. Therefore, an entire section is devoted to highlighting various chemical and bio-molecular modifications and explores how these permit the development of novel sensors with specific targets and functions. The review is completed with a discussion on novel detection strategies using nanopores. Although the most popular mode of nanopore sensing is based upon what has come to be known as ionic-current blockade sensing, there is a vast, growing literature based around exploring alternative detection techniques to further expand on the versatility of the sensors. Such techniques include optical, electronic, and force based methods. It is perhaps fair to say that these new frontiers have caused further excitement within the sensing community.
BackgroundTo date, biological components have been incorporated into MEMS devices to create cell-based sensors and assays, motors and actuators, and pumps. Bio-MEMS technologies present a unique opportunity to study fundamental biological processes at a level unrealized with previous methods. The capability to miniaturize analytical systems enables researchers to perform multiple experiments in parallel and with a high degree of control over experimental variables for high-content screening applications.Methodology/Principal FindingsWe have demonstrated a biological microelectromechanical system (BioMEMS) based on silicon cantilevers and an AFM detection system for studying the physiology and kinetics of myotubes derived from embryonic rat skeletal muscle. It was shown that it is possible to interrogate and observe muscle behavior in real time, as well as selectively stimulate the contraction of myotubes with the device. Stress generation of the tissue was estimated using a modification of Stoney's equation. Calculated stress values were in excellent agreement with previously published results for cultured myotubes, but not adult skeletal muscle. Other parameters such as time to peak tension (TPT), the time to half relaxation (½RT) were compared to the literature. It was observed that the myotubes grown on the BioMEMS device, while generating stress magnitudes comparable to those previously published, exhibited slower TPT and ½RT values. However, growth in an enhanced media increased these values. From these data it was concluded that the myotubes cultured on the cantilevers were of an embryonic phenotype. The system was also shown to be responsive to the application of a toxin, veratridine.Conclusions/SignificanceThe device demonstrated here will provide a useful foundation for studying various aspects of muscle physiology and behavior in a controlled high-throughput manner as well as be useful for biosensor and drug discovery applications.
While the molecular and biophysical mechanisms underlying cell protrusion on two-dimensional substrates are well understood, our knowledge of the actin structures driving protrusion in three-dimensional environments is poor, despite relevance to inflammation, development and cancer. Here we report that, during chemotactic migration through microchannels with 5 μm × 5 μm cross-sections, HL60 neutrophil-like cells assemble an actin-rich slab filling the whole channel cross-section at their front. This leading edge comprises two distinct F-actin networks: an adherent network that polymerizes perpendicular to cell-wall interfaces and a ‘free’ network that grows from the free membrane at the cell front. Each network is polymerized by a distinct nucleator and, due to their geometrical arrangement, the networks interact mechanically. On the basis of our experimental data, we propose that, during interstitial migration, medial growth of the adherent network compresses the free network preventing its retrograde movement and enabling new polymerization to be converted into forward protrusion.
This protocol describes a cell culture model to study the differentiation of fetal rat skeletal muscle cells. The model uses serum-free medium, a nonbiological substrate N-1[3(trimethoxysilyl)propyl] diethylenetriamine (DETA) and fabricated microcantilevers to promote the differentiation of dissociated rat myocytes into robust myotubes. In this protocol, we also describe how to characterize the myotubes on the basis of morphology, immunocytochemistry and electrophysiology. Here, four major techniques are employed: fabrication of cantilevers, surface modification of the glass and cantilever substrates with a DETA SAM, a serum-free medium and refined culture techniques. This culture system has potential applications in biocompatibility studies, bioartificial muscle engineering, skeletal muscle differentiation studies and for better understanding of myopathies and neuromuscular disorders. The model can be established in 26-33 d.
C-reactive protein (CRP) is an inflammatory biomarker of inflammation and may reflect progression of vascular disease. Conflicting evidence suggests CRP may be a prognostic biomarker of ischemic stroke outcome. Most studies that have examined the relationship between CRP and ischemic stroke outcome have used mortality or subsequent vascular event as the primary outcome measure. Given that nearly half of stroke patients experience moderate to severe functional impairments, using a biomarker like CRP to predict functional recovery rather than mortality may have clinical utility for guiding acute stroke treatments. The primary aim of this study was to systematically and critically review the relationship between CRP and long-term functional outcome in ischemic stroke patients to evaluate the current state of the literature. PubMed and MEDLINE databases were searched for original studies which assessed the relationship between acute CRP levels measured within 24 hours of symptom onset and long-term functional outcome. The search yielded articles published between 1989 and 2012. Included studies used neuroimaging to confirm ischemic stroke diagnosis, high-sensitivity CRP assay, and a functional outcome scale to assess prognosis beyond 30 days after stroke. Study quality was assessed using the REMARK recommendations. Five studies met all inclusion criteria. Results indicate a significant association between elevated baseline high sensitivity CRP and unfavorable long-term functional outcome. Our results emphasize the need for additional research to characterize the relationship between acute inflammatory markers and long-term functional outcome using well-defined diagnostic criteria. Additional studies are warranted to prospectively examine the relationship between high sensitivity CRP measures and long-term outcome.
Although it is well documented that proteins adsorb onto biomaterial surfaces, relatively little is quantitatively understood about the effects of adsorption on protein orientation and conformation. Because this is the primary determining factor of protein bioactivity, the ability to accurately predict a protein's orientation and conformation following adsorption will be essential for the rational design of biomaterial surfaces to control biological responses. Force field-based computational chemistry methods provide an excellent means to theoretically address this issue, with the nontrivial requirement that the force field must be tailored to appropriately represent protein adsorption behavior. Accordingly, we have modified an existing force field (CHARMm) based on semiempirical quantum-mechanical peptide adsorption data to enable it to simulate protein adsorption behavior in an implicit aqueous environment. This modified force field was then applied to predict the adsorption behavior of the 7-10 type III repeats of fibronectin on functionalized surfaces. Predicted changes in adsorption energy and adsorption-induced conformation as a function of surface chemistry were found to correlate well with experimentally observed trends for these same systems. This work represents a first attempt towards the development of a molecular mechanics force field that is specifically parameterized to accurately simulate protein adsorption to biomaterial surfaces.
A Whispering Gallery Mode (WGM) biosensor was constructed to measure the adsorption of protein onto alkysilane self-assembled monolayers (SAMs) at solution concentrations unattainable with other techniques. The high sensitivity was provided by a WGM resonance excited in a silica microsphere that was functionalized with alkylsilane SAMs and integrated in a microfluidic flow cell under laminar flow conditions. It was found that FN adsorbed at biologically relevant surface densities, however, the adsorption kinetics and concentration dependent saturation values varied significantly from work published utilizing alkanethiol SAMs. Mathematical models were applied to the experimental results to interpret the observed kinetics of FN adsorption. Embryonic hippocampal neurons and skeletal myoblasts were cultured on the modified surfaces, and a live-dead assay was used to determine the viability of the FN surfaces for cell culture, and major differences were noted in the biological response to the different SAMs. The high sensitivity and simplicity of the WGM biosensor, combined with its ability to quantify the adsorption of any dilute protein in a label-free assay, establishes the importance of this technology for the study of surface accretion and its effect on cellular function, which can affect biomaterials for both in vivo and in vitro applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.