Suppression of stimulated Raman scattering (SRS) by means of chirped and tilted fiber Bragg gratings (CTFBGs) has become a key topic. However, research on high-power systems is still lacking due to two problems. Firstly, after the inscription, there are a large number of hydroxyl compounds and hydrogen molecules in CTFBGs that cause significant heating due to their strong infrared absorption. Secondly, CTFBGs can couple Stokes light from the core to the cladding and the coating, which causes serious heating in the coating of the CTFBG. Aimed at overcoming these bottlenecks, a process that combines constant-low-temperature and variable-high-temperature annealing is used to reduce the thermal slope of the CTFBG. Also, a segmented-corrosion cladding power stripping technology is used on the CTFBG to remove the Stokes light which is coupled to the cladding, which solves the problem of overheating in the coating of the CTFBG. Thereby, a CTFBG with both a kilowatt-level power-carrying load and the ability to suppress SRS in a fiber laser has been developed. Further, we establish a kW-level CW oscillator to test the CTFBG. Experimental results demonstrate that the power-carrying load of the CTFBG is close to 1 kW, the thermal slope is lower than $0.015\,^{\circ }\text{C}/\text{W}$, and the SRS suppression ratio is nearly 23 dB.
Two long-period fiber gratings (LPFGs) used to separately suppress the stimulated-Raman-scattering (SRS) in the seed and amplifier of kW-level continuous-wave (CW) MOPA fiber laser are developed in this paper. A process that combines constant-low-temperature and dynamic-high-temperature annealing was employed to reduce the thermal slopes of 10/130 µm (diameter of core/cladding fiber) and 14/250 LPFGs, used in the seed and amplifier respectively, from 0.48 °C/W to 0.04 °C/W and from 0.53 °C/W to 0.038 °C/W. We also proposed a reduced-sensitivity packaging method to effectively reduce the influence of axial-stress, bending, and environmental temperature on LPFGs. Further, we established a kW-level CW MOPA system to test SRS suppression performance of the LPFGs. Experimental results demonstrated that the SRS suppression ratios of the 10/130 and 14/250 LPFGs exceed 97.0% and 99.6%, respectively.
Suppressing nonlinear effects in high-power fiber lasers based on fiber gratings has become a hotspot. At present, research is mainly focused on suppressing stimulated Raman scattering in a high-power fiber laser. However, the suppression of spectral broadening, caused by self-phase modulation or four-wave mixing, is still a challenging attribute to the close distance between the broadened laser and signal laser. If using a traditional fiber grating with only one stopband to suppress the spectral broadening, the signal power will be stripped simultaneously. Confronting this challenge, we propose a novel method based on phase-shifted long-period fiber grating (PS-LPFG) to suppress spectral broadening in a high-power fiber master oscillator power amplifier (MOPA) laser system in this paper. A PS-LPFG is designed and fabricated on 10/130 passive fiber utilizing a point-by-point scanning technique. The resonant wavelength of the fabricated PS-LPFG is 1080 nm, the full width at half maximum of the passband is 5.48 nm, and stopband extinction exceeds 90%. To evaluate the performance of the PS-LPFG, the grating is inserted into the seed of a kilowatt-level continuous-wave MOPA system. Experiment results show that the 30 dB linewidth of the output spectrum is narrowed by approximately 37.97%, providing an effective and flexible way for optimizing the output linewidth of high-power fiber MOPA laser systems.
In bio-medical mobile workstations, e.g., the prevention of epidemic viruses/bacteria, outdoor field medical treatment and bio-chemical pollution monitoring, the conventional bench-top microscopic imaging equipment is limited. The comprehensive multi-mode (bright/dark field imaging, fluorescence excitation imaging, polarized light imaging, and differential interference microscopy imaging, etc.) biomedical microscopy imaging systems are generally large in size and expensive. They also require professional operation, which means high labor-cost, money-cost and time-cost. These characteristics prevent them from being applied in bio-medical mobile workstations. The bio-medical mobile workstations need microscopy systems which are inexpensive and able to handle fast, timely and large-scale deployment. The development of lightweight, low-cost and portable microscopic imaging devices can meet these demands. Presently, for the increasing needs of point-of-care-test and tele-diagnosis, high-performance computational portable microscopes are widely developed. Bluetooth modules, WLAN modules and 3G/4G/5G modules generally feature very small sizes and low prices. And industrial imaging lens, microscopy objective lens, and CMOS/CCD photoelectric image sensors are also available in small sizes and at low prices. Here we review and discuss these typical computational, portable and low-cost microscopes by refined specifications and schematics, from the aspect of optics, electronic, algorithms principle and typical bio-medical applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.