Adequate fixation at the time of cementless stem implantation depends on the operator's experience. An objective evaluation method to determine whether the stem has been appropriately implanted may be helpful. We studied the relationship between the hammering sound frequency during stem implantation and internal stress in a femoral model, and evaluated the possible usefulness of hammering sound frequency analysis for preventing intraoperative fracture. Three types of cementless stem (BiCONTACT®, SL-PLUS®, and AI-Hip®) were used. Surgeons performed stem insertion using a procedure similar to that employed in a routine operation. Stress was estimated by finite element analysis, the hammering force was measured, and frequency analysis of hammering sound data obtained using a microphone. Finite element analysis showed a decrease in the hammering sound frequency with an increase in the estimated maximum stress. When a decrease in frequency was observed, adequate hammering had occurred, and the continuation of hammering risked fracture. Based on the relationship between stress and frequency, the evaluation of changes in frequency may be useful for preventing the development of intraoperative fractures. Using our method, when a decrease in frequency is observed, the hammering force should be reduced. Hammering sound frequency analysis may allow the prediction of bone fractures that can be visually confirmed, and may be a useful objective evaluation method for the prevention of intraoperative periprosthetic fractures during stem insertion.
It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate). Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (P < 0.05). No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring.
We measured the frictional coefficient under banana skin on floor material. Force transducer with six degrees of freedom was set under a flat panel of linoleum. Both frictional force and vertical force were simultaneously measured during a shoe sole was pushed and rubbed by a foot motion on the panel with banana skin. Measured frictional coefficient was about 0.07. This was much lower than the value on common materials and similar one on well lubricated surfaces. By the microscopic observation, it was estimated that polysaccharide follicular gel played the dominant role in lubricating effect of banana skin after the crush and the change to homogeneous sol.
The three-dimensional ultrastructure of glomerular basement membrane (GBM) and mesangial matrix (MM) at an early stage of streptozotocin (STZ)-induced diabetes mellitus in rats was examined by the quick-freezing and deep-etching method. In diabetic rats, the GBM inner layer was diffusely enlarged and the meshwork structure not only in the GBM middle layer but also in the MM became markedly irregular due to the rupture of fine fibrils. This irregularity and enlargement of the mesh pores in diabetic rats developed during the experimental period and was significantly different from results in control rats. Insulin treatment from 1 week after STZ injection had significant effects in preventing the ultrastructural changes in the GBM and MM. It is suggested that early insulin treatment has significant effects in preventing size barrier disturbance of GBM and MM in STZ-induced diabetes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.