Republication or reproduction of this report or its storage and/or dissemination by electronic means is permitted without theAbstract: The definition of a "primary method of measurement" [1] has permitted a full consideration of the definition of primary standards for pH, determined by a primary method (cell without transference, Harned cell), of the definition of secondary standards by secondary methods, and of the question whether pH, as a conventional quantity, can be incorporated within the internationally accepted system of measurement, the International System of Units (SI, Système International d'Unités). This approach has enabled resolution of the previous compromise IUPAC 1985 Recommendations [2]. Furthermore, incorporation of the uncertainties for the primary method, and for all subsequent measurements, permits the uncertainties for all procedures to be linked to the primary standards by an unbroken chain of comparisons. Thus, a rational choice can be made by the analyst of the appropriate procedure to achieve the target uncertainty of sample pH. Accordingly, this document explains IUPAC recommended definitions, procedures, and terminology relating to pH measurements in dilute aqueous solutions in the temperature range 5-50 °C. Details are given of the primary and secondary methods for measuring pH and the rationale for the assignment of pH values with appropriate uncertainties to selected primary and secondary substances.
Republication or reproduction of this report or its storage and/or dissemination by electronic means is permitted without the Measurement of pH. Definition, standards, and procedures (IUPAC Recommendations 2002)Abstract: The definition of a "primary method of measurement" [1] has permitted a full consideration of the definition of primary standards for pH, determined by a primary method (cell without transference, Harned cell), of the definition of secondary standards by secondary methods, and of the question whether pH, as a conventional quantity, can be incorporated within the internationally accepted system of measurement, the International System of Units (SI, Système International d'Unités). This approach has enabled resolution of the previous compromise IUPAC 1985 Recommendations [2]. Furthermore, incorporation of the uncertainties for the primary method, and for all subsequent measurements, permits the uncertainties for all procedures to be linked to the primary standards by an unbroken chain of comparisons. Thus, a rational choice can be made by the analyst of the appropriate procedure to achieve the target uncertainty of sample pH. Accordingly, this document explains IUPAC recommended definitions, procedures, and terminology relating to pH measurements in dilute aqueous solutions in the temperature range 5-50 °C. Details are given of the primary and secondary methods for measuring pH and the rationale for the assignment of pH values with appropriate uncertainties to selected primary and secondary substances.
An absolute determination of aqueous electrolytic conductivity has been made for 0.01 molal (m) and 0.1 m potassium cliloride solutions, over the temperature range of 0 to 50 °C in 5 degree intervals. A cell with a removable center section of accurately known length and area was used for the measurements. Values were adjusted to be in conformity with the ITS-90 temperature scale. The overall uncertainty over the entire temperature range is estimated to be 0.03%. Values at 25 °C for 0.01 and 0.1 m are 0.00140823 and 0.0128246 S/cm, respectively. It is proposed that these values be adopted as primary standards for aqueous electrolytic conductivity, replacing the demal scale.
Republication or reproduction of this report or its storage and/or dissemination by electronic means is permitted without theAbstract: New values of electrolytic conductivity were determined for aqueous KCl solutions with molalities of 0.01, 0.1, and 1.0 mol/kg in the temperature range 0 to 50 °C, at 5 K intervals. Expanded uncertainties, 2u c , were also calculated in accordance with the presently accepted protocol for the treatment of uncertainty. The new conductivity values are recommended as primary standards of electrolytic conductivity based on molality. They replace the previous values, based on the nonstandard demal scale, which were determined only at 0, 18, and 25°C. The accuracy of the technique used was evaluated by repeating the determination of the previously recommended demal-based IUPAC standards of electrolytic conductivity and through comparison with other absolute measurements.
A review of the state of the art of electrochemical methods at the highest metrology level in national metrology institutes (NMIs) is given, with emphasis on standardization work (primary methods) in the fields of pH and electrolytic conductivity, as well as use of coulometry. Attention is also given to certain technical issues in the implementation of these methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.