The ability to disinfect and reuse disposable N95 filtering facepiece respirators (FFRs) may be needed during a pandemic of an infectious respiratory disease such as influenza. Ultraviolet germicidal irradiation (UVGI) is one possible method for respirator disinfection. However, UV radiation degrades polymers, which presents the possibility that UVGI exposure could degrade the ability of a disposable respirator to protect the worker. To study this, we exposed both sides of material coupons and respirator straps from four models of N95 FFRs to UVGI doses from 120–950 J/cm2. We then tested the particle penetration, flow resistance, and bursting strengths of the individual respirator coupon layers, and the breaking strength of the respirator straps. We found that UVGI exposure led to a small increase in particle penetration (up to 1.25%) and had little effect on the flow resistance. UVGI exposure had a more pronounced effect on the strengths of the respirator materials. At the higher UVGI doses, the strength of the layers of respirator material was substantially reduced (in some cases, by >90%). The changes in the strengths of the respirator materials varied considerably among the different models of respirators. UVGI had less of an effect on the respirator straps; a dose of 2360 J/cm2 reduced the breaking strength of the straps by 20–51%. Our results suggest that UVGI could be used to effectively disinfect disposable respirators for reuse, but the maximum number of disinfection cycles will be limited by the respirator model and the UVGI dose required to inactivate the pathogen.
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei "bioaerosols" were assessed. Monodisperse 0.25-1.9-µm fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m 3 water closet (WC). Bowl water seeding was approximately 10 12 particles/mL. Droplet nuclei were sampled onto 0.2-µm pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre-and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets <2 µm diameter and >99% <5 µm. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms-splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei.
Research suggests that toilet plume could play a contributory role in the transmission of infectious diseases. Additional research in multiple areas is warranted to assess the risks posed by toilet plume, especially within health care facilities.
Release on the MMWR website (https://www.cdc.gov/mmwr).SARS-CoV-2, the virus that causes COVID-19, can be spread by exposure to droplets and aerosols of respiratory fluids that are released by infected persons when they cough, sing, talk, or exhale. To reduce indoor transmission of SARS-CoV-2 between persons, CDC recommends measures including physical distancing, universal masking (the use of face masks in public places by everyone who is not fully vaccinated), and increased room ventilation (1). Ventilation systems can be supplemented with portable high efficiency particulate air (HEPA) cleaners* to reduce the number of infectious particles in the air and provide enhanced protection from transmission between persons (2); two recent reports found that HEPA air cleaners in classrooms could reduce overall aerosol particle concentrations by ≥80% within 30 minutes (3,4). To investigate the effectiveness of portable HEPA air cleaners and universal masking at reducing exposure to exhaled aerosol particles, the investigation team used respiratory simulators to mimic a person with COVID-19 and other, uninfected persons in a conference room. The addition of two HEPA air cleaners that met the Environmental Protection Agency (EPA)-recommended clean air delivery rate (CADR) (5) reduced overall exposure to simulated exhaled aerosol particles by up to 65% without universal masking. Without the HEPA air cleaners, universal masking reduced the combined mean aerosol concentration by 72%. The combination of the two HEPA air cleaners and universal masking reduced overall exposure by up to 90%. The HEPA air cleaners were most effective when they were close to the aerosol source. These findings suggest that portable HEPA air cleaners can reduce exposure to SARS-CoV-2 aerosols in indoor environments, with greater reductions in exposure occurring when used in combination with universal masking.A breathing aerosol source simulator was used to mimic a meeting participant exhaling infectious particles (source), and three breathing simulators were used to mimic a speaker and two participants exposed to these aerosol particles (receivers) (Figure 1). The methods used were similar to those used in previous studies of aerosol dispersion and transport in indoor spaces (3,4,6). The simulators were placed in a 584-ft 2 (54-m 2 ) * HEPA air cleaners consist of a filter capable of removing ≥99.97% of particles from the air and a fan or blower to draw air through the filter. HEPA air cleaners are commercially available, relatively inexpensive, and easy to use.
Ambulances are frequently contaminated with infectious microorganisms shed by patients during transport that can be transferred to subsequent patients and emergency medical service workers. Manual decontamination is tedious and time-consuming, and persistent contamination is common even after cleaning. Ultraviolet germicidal irradiation (UVGI) has been proposed as a terminal disinfection method for ambulance patient compartments. However, no published studies have tested the use of UVGI in ambulances. The objectives of this study were to investigate the efficacy of a UVGI system in an ambulance patient compartment and to examine the impact of UVGI fixture position and the UV reflectivity of interior surfaces on the time required for disinfection. A UVGI fixture was placed in the front, middle, or back of an ambulance patient compartment, and the UV irradiance was measured at 49 locations. Aluminum sheets and UV-reflective paint were added to examine the effects of increasing surface reflectivity on disinfection time. Disinfection tests were conducted using Bacillus subtilis spores as a surrogate for pathogens. Our results showed that the UV irradiance varied considerably depending upon the surface location. For example, with the UVGI fixture in the back position and without the addition of UV-reflective surfaces, the most irradiated location received a dose of UVGI sufficient for disinfection in 16 s, but the least irradiated location required 15 hr. Because the overall time required to disinfect all of the interior surfaces is determined by the time required to disinfect the surfaces receiving the lowest irradiation levels, the patient compartment disinfection times for different UVGI configurations ranged from 16.5 hr to 59 min depending upon the UVGI fixture position and the interior surface reflectivity. These results indicate that UVGI systems can reduce microbial surface contamination in ambulance compartments, but the systems must be rigorously validated before deployment. Optimizing the UVGI fixture position and increasing the UV reflectivity of the interior surfaces can substantially improve the performance of a UVGI system and reduce the time required for disinfection.
Extraordinary incidents resulting in airborne infectious disease outbreaks could produce patient isolation requirements that exceed most hospitals' capacity. This article investigates expedient methods to establish airborne infection isolation areas using a commercially available portable filtration unit and common hardware supplies. The study was conducted within a conventional, nonisolation hospital room, and researchers evaluated several airborne isolation configurations that did not require building ventilation or structural modifications. A portable high-efficiency particulate air filtration unit and full-length plastic curtains established a "zone-within-zone" protective environment using local capture and directional airflows. The cost of constructing the expedient configurations was less than US2,300 dollars and required fewer than 3 person-hours to construct. A medical nebulizer aerosolized polystyrene latex microspheres to generate respirable condensation nuclei. Aerosol spectrometers sized and counted respirable particles at the source patient and health care worker positions and in areas outside the inner zone. The best-performing designs showed no measurable source migration out of the inner isolation zone and mean respirable particle counts up to 87% lower at the health care worker position(s) than those observed directly near the source patient location. Investigators conclude that with careful implementation under emergency circumstances in which engineered isolation rooms are unavailable, expedient methods can provide affordable and effective patient isolation while reducing exposure risks and potential disease transmission to health care workers, other patients, and visitors.
When infectious epidemics occur, they can be perpetuated within health care settings, potentially resulting in severe health care workforce absenteeism, morbidity, mortality, and economic losses. The ventilation system configuration of an airborne infection isolation room is one factor that can play a role in protecting health care workers from infectious patient bioaerosols. Though commonly associated with airborne infectious diseases, the airborne infection isolation room design can also impact other transmission routes such as short-range airborne as well as fomite and contact transmission routes that are impacted by contagion concentration and recirculation. This article presents a computational fluid dynamics study on the influence of the ventilation configuration on the possible flow path of bioaerosol dispersal behavior in a mock airborne infection isolation room. At first, a mock airborne infection isolation room was modeled that has the room geometry and layout, ventilation parameters, and pressurization corresponding to that of a traditional ceiling-mounted ventilation arrangement observed in existing hospitals. An alternate ventilation configuration was then modeled to retain the linear supply diffuser in the original mock airborne infection isolation room but interchanging the square supply and exhaust locations to place the exhaust closer to the patient source and allow clean air from supply vents to flow in clean-to-dirty flow paths, originating in uncontaminated parts of the room prior to entering the contaminated patient’s air space. The modeled alternate airborne infection isolation room ventilation rate was 12 air changes per hour. Two human breathing models were used to simulate a source patient and a receiving health care worker. A patient cough cycle was introduced into the simulation, and the airborne infection dispersal was tracked in time using a multi-phase flow simulation approach. The results from the alternate configuration revealed that the cough aerosols were pulled by the exhaust vent without encountering the health care worker by 0.93 s after patient coughs and the particles were controlled as the aerosols’ flow path was uninterrupted by an air particle streamline from patient to the ceiling exhaust venting out cough aerosols. However, not all the aerosols were vented out of the room. The remaining cough aerosols entered the health care worker’s breathing zone by 0.98 s. This resulted in one of the critical stages in terms of the health care worker’s exposure to airborne virus and presented the opportunity for the health care worker to suffer adverse health effects from the inhalation of cough aerosols. Within 2 s, the cough aerosols reentered and recirculated within the patient and health care worker’s surroundings resulting in pockets of old contaminated air. By this time, coalescence losses decreased as the aerosol were no longer in very close proximity and their movement was primarily influenced by the airborne infection isolation room airflow patterns. In the patient and heal...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.