This article describes the design and performance of the muon monitor for the T2K (Tokai-to-Kamioka) long baseline neutrino oscillation experiment. The muon monitor consists of two types of detector arrays: ionization chambers and silicon PIN photodiodes. It measures the intensity and profile of muons produced, along with neutrinos, in the decay of pions. The measurement is sensitive to the intensity and direction of the neutrino beam. The linearity and stability of the detectors were measured in beam tests to be within 2.4% and 1.5%, respectively. Based on the test results, the precision of the beam direction measured by the muon monitor is expected to be 0.25 mrad.
This study aimed to evaluate the effects of dietary lysine/protein ratio and fat levels on the growth, carcass characteristics and meat quality of finishing pigs fed feed made from food waste, including noodles and chocolate. Four dietary treatments, 2 levels of lysine/protein ratio (0.035 and 0.046) and 2 levels of fat (3.3% and 6.0%), were adapted to a 2 × 2 factorial arrangement. Each diet for the finishing pigs contained the same levels of adequate crude protein (16%) and lysine (0.58-0.75%), and similar levels of high total digestible nutrients (90.2-92.6%). In total, 32 LWD pigs with an average body weight of 57.2 kg were assigned to 4 dietary groups. The pigs were slaughtered at about 115 kg. Growth performance was not influenced by the dietary treatments. Carcass characteristics were slightly influenced by the dietary fat level. As the dietary lysine/protein ratio decreased, the marbling score of Longissimus dorsi muscle increased and the intramuscular fat (IMF) increased from 6.82% to 9.46%. Marbling score was not significantly influenced by the dietary fat level. These results indicate that IMF increased without adverse effects on growth, carcass characteristics and meat quality, when pigs were fed a diet with low lysine/protein ratio.
We assemble bistable silicon quantum dots consisting of four buckled atoms (Si4-QD) using atom manipulation. We demonstrate two competing atom switching mechanisms, downward switching induced by tunneling current of scanning tunneling microscopy (STM) and opposite upward switching induced by atomic force of atomic force microscopy (AFM). Simultaneous application of competing current and force allows us to tune switching direction continuously. Assembly of the few-atom Si-QDs and controlling their states using versatile combined AFM/STM will contribute to further miniaturization of nanodevices.
A one-dimensional grating (1D grating) is one of the most important reference standards to calibrate nanometrological instruments, such as a critical dimension scanning electron microscope. Recently, the resolutions of nanometrological instruments have become higher, and 1D grating standards with smaller pitches are required. Based on this demand, 1D gratings with 25 nm pitch consisting of Si/SiO2 multilayer thin-film structures have been developed. Furthermore, pitch calibrations using metrological atomic force microscopes (metrological AFMs) and an x-ray diffractometer have been applied. In this study, the results of a 25 nm pitch comparison between a length-and-angle-standards-traceable x-ray diffractometer and a metrological AFM are reported.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.