The purpose of this study was to assess the efficacy and toxicity of intensity-modulated radiation therapy (IMRT) in the treatment of gastric cancer. Seven patients with gastric cancer were treated with IMRT. Six patients (all Stage III) received post-operative chemoradiotherapy with concurrent 5-fluorouracil and leucovorin. One received planned pre-operative radiation, though did not proceed to surgery. All patients were planned to receive 50.4 Gy in 1.8 Gy fractions. IMRT planning was compared with opposed anterior-posterior: posterior-anterior (AP/PA) and 3-field conventional three-dimensional plans. When compared with either AP/PA or 3-field plans, IMRT significantly reduced the volume exceeding the threshold dose of the liver and at least one kidney. Target coverage with IMRT was excellent, with 98+/-1% of the target receiving >or=100% of the dose. Compared with AP/PA and 3-field plans, IMRT plans had a greater percentage of target receiving the prescribed dose, but also a greater volume receiving >110% of the dose. IMRT was well tolerated; no patients developed acute gastrointestinal toxicity greater than grade 2. All seven experienced grade 2 nausea, three had grade 2 diarrhoea and two had grade 2 oesophagitis. Weight loss ranged from 0-12% (mean 6.1% and median 5.8%). IMRT in the treatment of gastric malignancies reduces the mean and above threshold doses to critical normal tissues. In an initial cohort of seven patients, 50.4 Gy delivered by IMRT is well tolerated and safe.
The detection of oligometastatic adrenal metastases is increasing and there are limited data supporting the use of curative intent stereotactic body radiation therapy (SBRT) to treat patients with limited metastatic disease with adrenal involvement. Therefore, we utilized a prospectively maintained database of consecutive patients treated with SBRT for limited metastatic disease (5 sites) to identify patients with adrenal metastases. Patients were either treated on a three-fraction dose escalation protocol or a ten fraction off-protocol regimen.Outcomes including treated-metastasis control (TMC), distant control (DC), and overall survival (OS) were calculated by the Kaplan-Meier method. Ten patients with 13 adrenal metastases were identified for this case series. The median follow-up was 14.9 months. No patient experienced grade 3 toxicity. The most common grade 1-2 acute toxicities were fatigue (80%) and GI toxicity (40%). One patient experienced late grade 2 adrenal insufficiency. Overall, the 1-year TMC rate was 73%, DC was 30%, and OS was 90%. Three treated adrenal metastases progressed, all receiving the lowest BED 10 (43.2 Gy), corresponding to 24 Gy in 3 fractions.After treatment of adrenal metastases with SBRT, the median time to salvage chemotherapy was 5.3 months (range 1.0-38.8 months) and 1-year freedom from salvage chemotherapy was 44%. These results suggest that SBRT to adrenal metastases was tolerated with low toxicity in limited metastatic patients and control rates are promising. This study supports the growing body of literature treating patients with adrenal metastases with SBRT.
The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.
Stereotactic radiosurgery delivers radiation with great spatial accuracy. To achieve sub-millimeter accuracy for intracranial SRS, a head ring is rigidly fixated to the skull to create a fixed reference. For some patients, the invasiveness of the ring can be highly uncomfortable and not well tolerated. In addition, placing and removing the ring requires special expertise from a neurosurgeon, and patient setup time for SRS can often be long. To reduce the invasiveness, hardware limitations and setup time, we are developing a system for performing accurate head positioning without the use of a head ring. The proposed method uses real-time 6D optical position feedback for turning on and off the treatment beam (gating) and guiding a motorcontrolled 3D head motion compensation stage. The setup consists of a central control computer, an optical patient motion tracking system and a 3D motion compensation stage attached to the front of the LINAC couch. A styrofoam head cast was custom-built for patient support and was mounted on the compensation stage. The motion feedback of the markers was processed by the control computer, and the resulting motion of the target was calculated using a rigid body model. If the target deviated beyond a preset position of 0.2 mm, an automatic position correction was performed with stepper motors to adjust the head position via the couch mount motion platform. In the event the target deviated more than 1 mm, a safety relay switch was activated and the treatment beam was turned off. The feasibility of the concept was tested using five healthy volunteers. Head motion data were acquired with and without the use of motion compensation over treatment times of 15 min. On average, test subjects exceeded the 0.5 mm tolerance 86% of the time and the 1.0 mm tolerance 45% of the time without motion correction.
Earlier generations of Varian LINACs exhibited large dose variations for small MU segments in SMLC-IMRT delivery. Our results confirmed these findings. The dose delivery accuracy for SMLC-IMRT is significantly improved on TrueBeam compared to Trilogy for every combination of low MU/segment (1-10) and high dose rate (200-600 MU/min), in part due to the faster sampling rate (100 vs 20 Hz) and enhanced electronic integration of the MLC controller with the LINAC. SMLC-IMRT can be implemented on TrueBeam with higher dose accuracy per beam (±0.2% vs ±3%) than previous generations of Varian C-series LINACs for 1 MU/segment delivered at 600 MU/min).
identified one outlier cluster (0.34%) along Leaf offset Constancy (LoC) axis that coincided with TG-142 limits. Conclusion: Machine learning methods based on SVDD clustering are promising for developing automated QA tools and providing insights into their reliability and reproducibility.
BackgroundStudies suggest that patients with metastases limited in number and destination organ benefit from metastasis-directed therapy. Stereotactic body radiotherapy (SBRT) is commonly used for metastasis directed therapy in this group. However, the characterization of PET response following SBRT is unknown in this population. We analyzed our cohort of patients to describe the PET response following SBRT.MethodsPatients enrolled on a prospective dose escalation trial of SBRT to all known sites of metastatic disease were reviewed to select patients with pre- and post-therapy PET scans. Response to SBRT was characterized on PET imaging based on standard PET response criteria and compared to CT based RECIST criteria for each treated lesion.Results31 patients had PET and CT data available before and after treatment for analysis in this study. In total, 58 lesions were treated (19 lung, 11 osseous, 11 nodal, 9 liver, 6 adrenal and 2 soft tissue metastases). Median follow-up was 14 months (range: 3–41). Median time to first post-therapy PET was 1.2 months (range; 0.5-4.1). On initial post-therapy PET evaluation, 96% (56/58) of treated metastases responded to therapy. 60% (35/58) had a complete response (CR) on PET and 36% (21/58) had a partial response (PR). Of 22 patients with stable disease (SD) on initial CT scan, 13 had CR on PET, 8 had PR, and one had SD. Of 21 metastases with PET PR, 38% became CR, 52% remained PR, and 10% had progressive disease on follow-up PET. 10/35 lesions (29%) with an initial PET CR progressed on follow-up PET scan with median time to progression of 4.11 months (range: 2.75-9.56). Higher radiation dose correlated with long-term PET response.ConclusionsPET response to SBRT enables characterization of metastatic response in tumors non-measurable by CT. Increasing radiation dose is associated with prolonged complete response on PET.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.