The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline.Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.
Purpose To review the dose limits and standardize the three-dimenional (3D) radiographic definition for the organs at risk (OARs) for thoracic radiotherapy (RT), including the lung, proximal bronchial tree, esophagus, spinal cord, ribs, and brachial plexus. Methods and Materials The present study was performed by representatives from the Radiation Therapy Oncology Group, European Organization for Research and Treatment of Cancer, and Soutwestern Oncology Group lung cancer committees. The dosimetric constraints of major multicenter trials of 3D-conformal RT and stereotactic body RT were reviewed and the challenges of 3D delineation of these OARs described. Using knowledge of the human anatomy and 3D radiographic correlation, draft atlases were generated by a radiation oncologist, medical physicist, dosimetrist, and radiologist from the United States and reviewed by a radiation oncologist and medical physicist from Europe. The atlases were then critically reviewed, discussed, and edited by another 10 radiation oncologists. Results Three-dimensional descriptions of the lung, proximal bronchial tree, esophagus, spinal cord, ribs, and brachial plexus are presented. Two computed tomography atlases were developed: one for the middle and lower thoracic OARs (except for the heart) and one focusing on the brachial plexus for a patient positioned supine with their arms up for thoracic RT. The dosimetric limits of the key OARs are discussed. Conclusions We believe these atlases will allow us to define OARs with less variation and generate dosimetric data in a more consistent manner. This could help us study the effect of radiation on these OARs and guide high-quality clinical trials and individualized practice in 3D-conformal RT and stereotactic body RT.
IMPORTANCE Our previous studies demonstrated that tumors significantly decrease in size and metabolic activity after delivery of 45 Gy of fractionated radiatiotherapy (RT), and that metabolic shrinkage is greater than anatomic shrinkage. This study aimed to determine whether 18F-fludeoxyglucose–positron emission tomography/computed tomography (FDG-PET/CT) acquired during the course of treatment provides an opportunity to deliver higher-dose radiation to the more aggressive areas of the tumor to improve local tumor control without increasing RT-induced lung toxicity (RILT), and possibly improve survival. OBJECTIVE To determine whether adaptive RT can target high-dose radiation to the FDG-avid tumor on midtreatment FDG-PET to improve local tumor control of locally advanced non–small-cell lung cancer (NSCLC). DESIGN, SETTING, AND PARTICIPANTS A phase 2 clinical trial conducted at 2 academic medical centers with 42 patients who had inoperable or unresectable stage II to stage III NSCLC enrolled from November 2008, to May 2012. Patients with poor performance, more than 10% weight loss, poor lung function, and/or oxygen dependence were included, providing that the patients could tolerate the procedures of PET scanning and RT. INTERVENTION Conformal RT was individualized to a fixed risk of RILT (grade >2) and adaptively escalated to the residual tumor defined on midtreatment FDG-PET up to a total dose of 86 Gy in 30 daily fractions. Medically fit patients received concurrent weekly carboplatin plus paclitaxel followed by 3 cycles of consolidation. MAIN OUTCOMES AND MEASURES The primary end point was local tumor control. The trial was designed to achieve a 20% improvement in 2-year control from 34% of our prior clinical trial experience with 63 to 69 Gy in a similar patient population. RESULTS The trial reached its accrual goal of 42 patients: median age, 63 years (range, 45–83 years); male, 28 (67%); smoker or former smoker, 39 (93%); stage III, 38 (90%). Median tumor dose delivered was 83 Gy (range, 63–86 Gy) in 30 daily fractions. Median follow-up for surviving patients was 47 months. The 2-year rates of infield and overall local regional tumor controls (ie, including isolated nodal failure) were 82% (95% CI, 62%–92%) and 62% (95% CI, 43%–77%), respectively. Median overall survival was 25 months (95% CI, 12–32 months). The 2-year and 5-year overall survival rates were 52% (95% CI, 36%–66%) and 30% (95% CI, 16%–45%), respectively. CONCLUSIONS AND RELEVANCE Adapting RT-escalated radiation dose to the FDG-avid tumor detected by midtreatment PET provided a favorable local-regional tumor control. The RTOG 1106 trial is an ongoing clinical trial to validate this finding in a randomized fashion. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01190527
A substantial barrier to the single- and multi-institutional aggregation of data to supporting clinical trials, practice quality improvement efforts, and development of big data analytics resource systems is the lack of standardized nomenclatures for expressing dosimetric data. To address this issue, the American Association of Physicists in Medicine (AAPM) Task Group 263 was charged with providing nomenclature guidelines and values in radiation oncology for use in clinical trials, data-pooling initiatives, population-based studies, and routine clinical care by standardizing: (1) structure names across image processing and treatment planning system platforms; (2) nomenclature for dosimetric data (eg, dose-volume histogram [DVH]-based metrics); (3) templates for clinical trial groups and users of an initial subset of software platforms to facilitate adoption of the standards; (4) formalism for nomenclature schema, which can accommodate the addition of other structures defined in the future. A multisociety, multidisciplinary, multinational group of 57 members representing stake holders ranging from large academic centers to community clinics and vendors was assembled, including physicists, physicians, dosimetrists, and vendors. The stakeholder groups represented in the membership included the AAPM, American Society for Radiation Oncology (ASTRO), NRG Oncology, European Society for Radiation Oncology (ESTRO), Radiation Therapy Oncology Group (RTOG), Children's Oncology Group (COG), Integrating Healthcare Enterprise in Radiation Oncology (IHE-RO), and Digital Imaging and Communications in Medicine working group (DICOM WG); A nomenclature system for target and organ at risk volumes and DVH nomenclature was developed and piloted to demonstrate viability across a range of clinics and within the framework of clinical trials. The final report was approved by AAPM in October 2017. The approval process included review by 8 AAPM committees, with additional review by ASTRO, European Society for Radiation Oncology (ESTRO), and American Association of Medical Dosimetrists (AAMD). This Executive Summary of the report highlights the key recommendations for clinical practice, research, and trials.
Single crystal relaxor ferroelectrics of PZN-8%PT were investigated for potential application in ultrasound transducers. The full set of electromechanical properties was determined using combined resonance and laser interferometry techniques. Ultra-high length extensional coupling (k(33)) of 0.94 was observed, a 25% increase over Navy Type VI PZT ceramics. The thickness extensional coupling (k(t)) of 0.48 was comparable to PZT compositions, and the compliance S(33)(E) was a factor of six greater. To maximize height extensional coupling (k'(33)), while minimizing length extensional coupling k(31) in array elements, it was necessary to align the elements along the 100 crystallographic direction in the x-y plane. Mode coupling plots and test samples for array elements determined that width-to-height ratios of less than 0.5 were desired, similar to the requirement for polycrystalline PZT ceramics. Modeling of 1-3 composites and experimental results demonstrated that thickness coupling greater than 0.80 could be achieved with a 40% to 70% volume fraction of PZN-PT. Although this is a substantial increase over PZT 1-3 composites, with a thickness coupling coefficient of 0.66, it represents a smaller fraction of the length extensional coupling k(33). This reduction may be a consequence of the increased compliance of PZN-PT, which results in significant clamping by the polymer matrix. Ultrasonic transducers fabricated using PZN-8%PT 1-3 composites achieved experimental bandwidths as high as 141%. The pulse-echo responses displayed good agreement with modeled results using the Redwood equivalent circuit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.