We report a case of a 4-year-old boy with tetralogy of Fallot, pulmonary atresia, and hypoplastic pulmonary arteries who presented with mild hemoptysis and upper respiratory infection 3 weeks following percutaneous transluminal angioplasty for pulmonary artery stenosis. While pneumonia was initially suggested on early plain radiographs of the chest, a large pseudoaneurysm of a right lower lobe pulmonary artery branch was subsequently diagnosed with CT and angiography.
The results and complications of a single-center experience of stent implantation in old saphenous vein grafts (SVGs) need to be defined. The authors studied their initial consecutive 92 patients (125 stents, 1.4 stents/per patient) with a mean age of 67+/-9 years. The patients' mean saphenous vein graft (SVG) age was 10+/-4 years, and the mean left ventricular ejection fraction was 46%+/-15. Patient population included unstable angina (65%), stable angina (10%), myocardial infarction (21%), and silent ischemia (4%). The authors implanted 122 Palmaz-Schatz/biliary and three Gianturco-Roubin stents. They aimed at a balloon-artery ratio of 1.1/1.0. Procedural success, defined as stent deployment with <50% stenosis without death/Q-wave myocardial infarction/coronary artery bypass grafting (MI/CABG) was 95%. The mean luminal diameter (MLD) increased from 0.6+/-0.5 to 3.3+/-0.8 mm (p<0.001) and mean SVG stenosis diameter was decreased from 80%+/-14 to -10%+/-11 (p<0.001). Angiographic SVG lesions exhibited thrombus (17%), ulceration (38%), and plaque rupture (28%). Sixty-two patients were treated with warfarin and aspirin and 30 with ticlid and aspirin. Complications included death in three patients (3.3%) who sustained subacute stent thrombosis, and two of three had Q-wave MI. Distal embolization occurred in seven patients (8%); six of seven sustained a non Q-wave acute myocardial infarction (AMI); and one of seven a Q-wave MI. Eight (9%) patients had major groin hematoma, two had pseudoaneurysm (2.2%), one had arteriovenous (A-V) fistula (1.1%), two had vascular surgery (2.2%), nine had blood transfusion (9.8%), and three had stent migration (3.3%). Single-center experience with stents in SVGs indicates a highly successful procedural and angiographic immediate result. However, it was complicated by significant risk of non Q-wave MI due to distal coronary embolization which may affect prognosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.