Purpose To develop diagnostic reference levels (DRLs) and achievable doses (ADs) for the 10 most common adult computed tomographic (CT) examinations in the United States as a function of patient size by using the CT Dose Index Registry. Materials and Methods Data from the 10 most commonly performed adult CT head, neck, and body examinations from 583 facilities were analyzed. For head examinations, the lateral thickness was used as an indicator of patient size; for neck and body examinations, water-equivalent diameter was used. Data from 1 310 727 examinations (analyzed by using SAS 9.3) provided median values, as well as means and 25th and 75th (DRL) percentiles for volume CT dose index (CTDI), dose-length product (DLP), and size-specific dose estimate (SSDE). Applicable results were compared with DRLs from eight countries. Results More than 46% of the facilities were community hospitals; 13% were academic facilities. More than 48% were in metropolitan areas, 39% were suburban, and 13% were rural. More than 50% of the facilities performed fewer than 500 examinations per month. The abdomen and pelvis was the most frequently performed examination in the study (45%). For body examinations, DRLs (75th percentile) and ADs (median) for CTDI, SSDE, and DLP increased consistently with the patient's size (water-equivalent diameter). The relationships between patient size and DRLs and ADs were not as strong for head and neck examinations. These results agree well with the data from other countries. Conclusion DRLs and ADs as a function of patient size were developed for the 10 most common adult CT examinations performed in the United States. RSNA, 2017.
A recurring source of contention between clinicians and radiologists continues to be examination appropriateness when imaging pregnant patients. With the multitude of references on potential radiation risks to the fetus, radiologists tend to be cautious and hesitant about exposing the fetus to radiation. This tendency is often interpreted by referring physicians as intrusion into and delay in the care of their patients. The risk burden of radiation exposure to the fetus has to be carefully weighed against the benefits of obtaining a critical diagnosis quickly and using a single tailored imaging study. In general, there is lower than expected awareness of radiation risks to the fetus from imaging pregnant patients. Modalities that do not use ionizing radiation, such as ultrasonography and magnetic resonance imaging, should be the preferred examinations for evaluating an acute condition in a pregnant patient. However, no examination should be withheld when an important clinical diagnosis is under consideration. Exposure to ionizing radiation may be unavoidable, but there is no evidence to suggest that the risk to the fetus after a single imaging study and an interventional procedure is significant. All efforts should be made to minimize the exposure, with consideration of the risk versus benefit for a given clinical scenario.
The dramatic rise in the prevalence of obesity among children and adults in the United States over the last several decades has brought several new challenges to the delivery of healthcare. The increased utilization of and dependence on imaging for accurate and timely diagnosis has placed the radiology department in a unique position in the provision of care for the obese emergency patient. Radiology practices must be cognizant of the imaging challenges presented by the obese patient and adjust their imaging algorithms accordingly to optimize all types of diagnostic studies. The article systematically reviews common pitfalls and offers methods to improve image quality when using radiography, ultrasonography, and computed tomography to image the obese patient population.
Viewing dual-energy CT images may result in the greatest subjective lesion conspicuity and measured contrast-to-noise ratio at 50 keV with equal detection of hyperenhancing liver lesions compared with viewing 77-keV images alone. In addition, the radiation doses of dual-energy CT may be similar to those of single-energy CT.
This table and graph may help operators understand the trade-offs when prospectively trying to minimize dose and optimize image noise for selected reconstruction slice thicknesses on this type of 64-MDCT scanner.
Trauma is the leading cause of nonobstetric maternal mortality and a significant cause of fetal loss. Both major and minor trauma result in an increased risk of fetal loss. In major trauma, when there is concern for maternal injury, CT is the mainstay of imaging. The risks of radiation to the pregnancy are small compared with the risk of missed or delayed diagnosis of trauma. In minor trauma, when there is no concern for maternal injury but there is concern about the pregnancy, ultrasound is performed but is insensitive in diagnosing placental abruption. External fetal monitoring is used to dictate patient care.
It is commonly assumed that essentially all of the water in cells has the same ideal motional and colligative properties as does water in bulk liquid state. This assumption is used in studies of volume regulation, transmembrane movement of solutes and electrical potentials, solute and solution motion, solute solubility and other phenomena. To get at the extent and the source of non-ideally behaved water (an operational term dependent on the measurement method), we studied the motional and colligative properties of water in cells, in solutions of amino acids and glycine peptides whose surface characteristics are known, and in solution of bovine serum albumin, hemoglobin and some synthetic polypeptides. Solutions of individual amino acids with progressively larger hydrophobic side chains showed one perturbed water molecule (structured-slowed in motion) per nine square angstroms of hydrophobic surface area. Water molecules adjacent to hydrophobic surfaces form pentagonal structural arrays, as shown by X-ray diffraction studies, that are reported to be disrupted by heat, electric field, hydrostatic pressure and phosphorylation state. Hydrophilic amino acids demonstrated water destructuring (increased motion) that was attributed to dielectric realignment of dipolar water molecules in the electric field between charge groups. In solutions of proteins, several methods indicate the equivalent of 2-8 layers of structured water molecules extending beyond the protein surface, and we have recently demonstrated that induced protein conformational change modifies the extent of non-ideally behaved water. Water self-diffusion rate as measured in three different cell types was about half that of bulk water, indicating that most of the water in these cells was slower in motion than bulk water. In different cell types the extent of osmotically perturbed water ranged from less that half to almost all of the intracellular water. The assumption that essentially all intracellular water has ideal osmotic and motional behavior is not supported by the experimental findings. The non-ideally of cell water is an operational term. Therefore, the amount of non-ideally behaving water is dependent on the characteristics of water targeted, i.e. the measurement method, and a large fraction of it is explainable in mechanistic terms at a molecular level based on solute-solvent interactions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.