Aims Delay of progression from paroxysmal to persistent atrial fibrillation (AF) is an important measure of long-term success of AF treatment. However, published data on the impact of catheter ablation on AF progression are limited. This study evaluates whether radiofrequency (RF) catheter ablation delays the progression of AF compared with antiarrhythmic drug (AAD) treatment using current AF management guidelines. Methods This prospective, randomized, controlled, two-arm, open-label trial was conducted at 29 hospitals and medical centres across 13 countries. Patients were randomized 1 : 1 to RF ablation or AAD treatment. The primary endpoint was the rate of persistent AF/atrial tachycardia (AT) at 3 years. Results After early study termination following slow enrolment, 255 (79%) of the planned 322 patients were enrolled (RF ablation, n = 128, AAD, n = 127); 36% of patients in the RF ablation group and 41% in the AAD group completed 3 years of follow-up. For the primary endpoint, the Kaplan–Meier estimate of the rate of persistent AF/AT at 3 years was significantly lower with RF ablation [2.4% (95% confidence interval (CI), 0.6–9.4%)] than with AAD therapy [17.5% (95% CI, 10.7–27.9%); one-sided P = 0.0009]. Patients ≥65 years were ∼4 times more likely to progress to persistent AF/AT than patients <65 years, suggesting RF ablation can delay disease progression [hazard ratio: 3.87 (95% CI, 0.88–17.00); P = 0.0727]. Primary adverse events were reported for eight patients in the RF ablation group. Conclusions Radiofrequency ablation is superior to guideline-directed AAD therapy in delaying the progression from paroxysmal to persistent AF.
Purpose. The results of cryoballoon ablation (CBA) procedure have been mainly derived from studies conducted in experienced atrial fibrillation (AF) ablation centres. Here, we report on CBA efficacy and complications resulting from real practice of this procedure at both high- and low-volume centres. Methods. Among 62 Russian centres performing AF ablation, 15 (24%) used CBA technology for pulmonary vein isolation. The centres were asked to provide a detailed description of all CBA procedures performed and complications, if encountered. Results. Thirteen sites completed interviews on all CBAs in their centres (>95% of CBAs in Russia). Six sites were high-volume AF ablation (>100 AF cases/year) centres, and 7 were low-volume AF ablation. There was no statistical difference in arrhythmia-free rates between high- and low-volume centres (64.6 versus 60.8% at 6 months). Major complications developed in 1.5% of patients and were equally distributed between high- and low-volume centres. Minor procedure-related events were encountered in 8% of patients and were more prevalent in high-volume centres. Total event and vascular access site event rates were higher in women than in men. Conclusions. CBA has an acceptable efficacy profile in real practice. In less experienced AF ablation centres, the major complication rate is equal to that in high-volume centres.
Introduction While several studies have compared the radiofrequency current (RFC) and cryoablation for the treatment of patients with atrial fibrillation (AF), no study has monitored the long-term outcomes with the usage of implantable loop recorders (ILRs). Methods We enrolled 89 consecutive patients with nonvalvular paroxysmal AF (N = 44 for RFC and N = 45 for cryoballoon). The primary efficacy end point was the assessment of effectiveness for each group (RFC versus cryoballoon) when examining freedom from arrhythmia by monitoring with ECG, Holter, and implantable loop recoder (ILR). The primary safety end point compared rates of adverse events between both groups. The secondary efficacy end point examined the duration of the postablation blanking period from ILR retrieved data. Results The mean age of the study population was 56.6 ± 10.2 years, and the follow-up duration was 12 months. There were no differences in baseline patient characteristics between groups. At 12 months, the absolute effectiveness (measured by ILR) was 65.9% in the RFC group and 51.1% in the cryoballoon group (OR = 1.85; 95% CI: 0.79–4.35; p = 0.157), and the clinical effectiveness (measured by ECG and Holter) was 81.8% in the RFC group and 55.6% in the cryoballoon group (OR = 3.6; 95% CI: 1.37–9.46; p = 0.008). There was no difference in safety between both groups. Asymptomatic episodes were significantly more present in the RFC group as measured by ILRs (p < 0.010). In cryoballoon group, arrhythmia episodes were recorded equally irrespective of the follow-up method (i.e., ECG and Holter versus ILR (p > 0.010)). The blanking period does not seem to be as important in cryoballoon as compared to RFC. Conclusion RFC and cryoballoon ablation had similar absolute effectiveness at 12 months. ECG and Holter were effective when assessing the efficacy of the cryoballoon ablation; however, in the RFC group, ILR was necessary to accurately assess long-term efficacy.
a better efficacy of CB in men (p-value = 0.027) but not in women (p-value = 0.939).CB but not female sex was associated with a slightly higher risk of complication (CB OR= 1.01, 95%-CI 1.00-1.03, p=0.048). The total procedure time was shorter when CB was used (-23min with CB, p<0.001). ConclusionWomen are at higher risk for ablation failure than men and cryoballoon ablation is associated with less long-term failures in men but not in women. Technological device improvement specifically for female patients could lead to higher success rates in women.
In epilepsy patients during video-electroencephalographic monitoring there are various electrocardiographic (ECG) changes during the epileptic seizure, sometimes remaining at postictal period as well. In the literature, various cardiac rhythm and conduction disorders are described, ventricular and supraventricular disorders, ST segment shifts. Some among these might be life-threatening, probably leading to unexplained sudden death in epilepsy. In the review, we focus on the most common ECG changes in patients with ongoing epileptic seizures.
Background Acute post-ablation pericarditis is the most common complication of epicardial ablation of ventricular arrhythmias (VA), while regional pericarditis following an initially uneventful endocardial catheter ablation (CA) procedure is a rare and elusive diagnosis. Case summary We report a case of a 66-years old Russian female who developed chest pain accompanied by ECG changes—biphasic T waves in V1-V4 leads after an initially uncomplicated premature ventricular complex (PVC) CA procedure. After examination and investigations, including transthoracic echocardiography (TTE), cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CCT), she was diagnosed with regional pericarditis, which occurred even though the ablation was uneventful with the limited number of radiofrequency applications. Furthermore, the diagnosis was difficult due to normal body temperature and the absence of pericardial effusion and myocardial abnormalities on TTE, findings that are not characteristic of pericarditis. The patient's last office visit was in six months after the procedure. Neither patient had any complaints, nor there were any changes on ECG and TTE. Discussion Regional post-ablation pericarditis is a relatively rare type of postcardiac injury syndrome (PCIS). The varying severity of the PCIS clinical course makes the diagnosis of post-ablation pericarditis initially difficult, especially in patients undergoing an uneventful catheter ablation procedure. Non-invasive imaging modalities as cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CCT) should be considered initially in elusive cases of PCIS.
Background Early recurrences of atrial arrhythmias (ERAA) after atrial fibrillation (AF) catheter ablation do not predict procedural failure. A well-demarcated homogeneous lesion delivered by cryoballoon is less arrhythmogenic, and the recommended three-months blanking period may not refer to cryoballoon ablation (CBA). Objective We aimed to evaluate the predictive role of ERAA after second-generation CBA using an implantable loop recorder. Methods This prospective observational study enrolled 100 patients (58 males, median age 58) with paroxysmal/persistent AF undergoing pulmonary vein (PV) CBA using second-generation cryoballoon with simultaneous ECG loop recorder implantation. The duration of follow-up was 12 months, with scheduled visits at 3, 6 and 12 months. Results 99 patients from 100 completed the 12-month follow-up period. ERAA occurred in 31.3 % of patients. 83.9 % of patients with ERAA also developed late recurrences. The 12-month freedom from AF in patients with ERAA was significantly lower than in those without ERAA (p < 0.0001). Non-paroxysmal AF and longer arrhythmia history were associated with increased risk of both early (HR 3.27; 95 % CI 1.32–8.08; p = 0.010 and HR 1.0147; 95 % CI 1.008–1.086; p = 0.015, respectively) and late recurrences (HR 3.89; 95 % CI 1.67–9.04; p = 0.002 and HR 1.0142; 95 % CI 1.007–1.078; p = 0.019, respectively) of AF. ERAA were another predictor for procedural failure (HR 15.2; 95 % CI (6.42–35.99; p = 0.019). Conclusions ERAA occurred in the third of the patients after PV second-generation CBA and are strongly associated with procedural failure. Longer duration of AF history and persistent AF are independent predictors of AF’s early and late recurrence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.