Objective: To evaluate the benefits of bilateral electrical stimulation for hearing-impaired adult subjects using the Nucleus 24 cochlear implant in a multicenter study, and to compare and quantify performance on speech perception measures in quiet and in noise and localization ability for unilateral and bilateral cochlear implant use. Design: Repeated single subject measures were carried out for each subject, with each subject serving as their own control. Assessment of unilateral and bilateral listening conditions for performance on tests of speech comprehension and sound localization were performed. Speech comprehension measures were performed in quiet at 0 degree azimuth and in the presence of background noise simultaneously presented from the same speaker and spatially separated by 90 degrees, at S+45°N45°and at S−45°N+45°. Test materials included Freiburger monosyllabic words, Oldenburger sentences, and the Hochmair-Schulz-Moser sentences. Tests of localization were performed in the horizontal plane with 12 speaker locations 30 degrees apart using a shortened sentence stimulus from the Hochmair-Schulz-Moser sentences at two possible presentation levels of 55 and 70 dB sound pressure level for assessment of directionality. The binaural advantage provided by bilateral stimulation was calculated with respect to each ear separately, classified as either the better or poorer performing ear for each speech material in quiet and in noise test conditions. For localization of sound, the binaural advantage was compared with left and right ears separately. Paired comparisons for performance data in all conditions were carried out by considering measurements for each subject in different conditions as paired observations and applying the Student's t test to determine the statistical difference between the data sets. Setting: Tertiary referral centers with a cochlear implant program. Patients: Thirty-seven profoundly hearing-impaired adults were enrolled in the study, 22 simultaneously and 15 sequentially bilaterally implanted. All patients received the Nucleus 24 cochlear implant and used the Nucleus SPrint or ESPrit 3G speech processor, with the vast majority using the ACE speech coding strategy. Results: For spatially separated speech in noise conditions, an interaural performance advantage for the ear closest to the speech source (i.e., with a superior signal to noise ratio) compared with that for the ear closest to the noise source (i.e., with an inferior signal to noise ratio) is consistently demonstrated regardless of whether it is the better or poorer performing ear closest to the speech signal. This is referred to as a significant binaural head-shadow benefit, resulting in a mean improvement between −10 dB and −11.4 dB in the critical signal to noise ratio required for 50% speech comprehension for the Oldenburger sentences and a mean improvement in the maximum score of 42% to 55% for the ear closest to the speech signal over the ear farthest away for the Hochmair-Schulz-Moser sentences. Bilateral stimulation i...
The present multicentric clinical study involves 19 centres, 16 of them in German-speaking countries, 1 British, 1 Polish and 1 Hungarian. 60 postlingually deafened adults with a mean age of 47.5 years (20–70) and a mean duration of deafness of 5.3 years (0.5–20) have been evaluated with the MED-EL COMBI 40 cochlear implant which implements a high-rate continuous-interleaved-sampling strategy with 8 channels. Safety and effectiveness data have been collected. Speech perception tests include a 16-consonant, an 8-vowel, a sentence and a monosyllabic-word test in all languages and a 2-digit figure test in all languages but English. Test intervals are 1,3,6 months and 1 year after first fitting. 41 of the 60 postlingually deafened adult study patients have completed their 6-month evaluation. While their pre-operative monosyllabic-word score was 0%, their mean monosyllabic-word score 6 months after first fitting was 48% (8–90) with a median of 50%. The mean sentence understanding was 84% (24–100) with a median of 90%. The respective values for the 1-year evaluations with 25 patients are a mean of 50% (5–85), with a median of 60%, for the monosyllables and a mean of 89% (30–100), with a median of 97%, for the sentences.
AutoNRT provides comparable accuracy to an average clinician but with the added benefit of significant time savings over manual recordings. This makes it a valuable tool for clinical measurement of ECAP threshold in cochlear implant recipients.
Training in microsurgery of the middle ear requires dissecting to be carried out on petrous bone. Human petrous bone structures are not available in adequate quantity to permit extensive practicing. Using synthetic resins, true reproductions of petrous bone can be obtained by means of a stereolithographic method, yielding structures of the petrous part which are highly similar to human bone. Digital data sets are obtained from spiral CT scans, and transferred to CAD systems such that, using stereolithography, petrous bone facsimiles are produced on the parametric model. Any number of such models of an original can be produced. Thus, identical structures can be made available for a wide range of uses. Exercises conducted on artificial petrous bone so produced are equivalent to those carried out on human structures, in terms of material properties and visualisation of anatomic details.
A study was conducted to compare the new MED-EL TEMPO+ ear-level speech processor with the CIS PRO+ body-worn processor in the COMBI 40/COMBI 40+ implant system. Speech tests were performed in 46 experienced subjects in two test sessions approximately 4 weeks apart. Subjects were switched over from the CIS PRO+ to the TEMPO+ in the first session and used only the TEMPO+ in the time between the two sessions. Speech tests included monosyllabic word tests and sentence tests via the telephone. An adaptive noise method was used to adjust each subject’s scores to approximately 50%. Additionally, subjects had to complete a questionnaire based on their 4 weeks of experience with the TEMPO+. The speech test results showed a statistically significant improvement in the monosyllabic word scores with the TEMPO+. In addition, in the second session, subjects showed a significant improvement when using the telephone with the TEMPO+, indicating some learning in this task. In the questionnaire, the vast majority of subjects found that the TEMPO+ allows equal or better speech understanding and rated the sound quality of the TEMPO+ higher. All these objective and subjective results indicate the superiority of the TEMPO+ and are mainly attributed to a new coding strategy called CIS+ and its implementation in the TEMPO+. In other words, based on the results of this study, it appears that after switching over from the CIS PRO+ to the TEMPO+, subjects are able to maintain or even improve their own speech understanding capability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.