The results in these patients suggest that cochlear implantation improves hearing abilities in people with single-sided deafness and is superior to the alternative treatment options. The use of the CI does not interfere with speech understanding in the normal hearing ear. Our data suggest that the binaural integration of electric and acoustic stimulation is possible even with unilateral normal hearing.
Results of studying the Contour array influenced the surgical procedure that improved surgical ability to perform insertions into the scala tympani by using the Contour Advance array. In addition, a comparison between Contour and Contour Advance electrode demonstrated an improved mechanical behavior of the Contour Advance electrode with a decrease of dislocation rate. The use of the Contour Advance electrode allows a more atraumatic electrode insertion, which is of interest with extending indications and the use of further advanced coding strategies. The intracochlear electrode position with regard to speech performance results demonstrated advantages of scala tympani insertions.
For adult patients with single-sided deafness (SSD), treatment with a cochlear implant (CI) is well established as an acceptable and beneficial hearing rehabilitation method administered routinely in clinical practice. In contrast, for children with SSD, CI has been applied less often to date, with the rationale to decide either on a case-by-case basis or under the realm of clinical research. The aim of our clinical study was to evaluate the longitudinal benefits of CI for a group of children diagnosed with SSD and to compare their outcomes with respect to patient characteristics. Evaluating a pool of paediatric SSD patients presenting for possible CI surgery revealed that the primary aetiology of deafness was congenital cochlear nerve deficiency. A subgroup of children meeting the CI candidacy criteria for the affected ear (the majority with acquired hearing loss) were enrolled in the study. Preliminary group results suggest substantial improvements in speech comprehension in noise and in the ability to localise sound, which was demonstrated through objective and subjective assessments after CI treatment for the group, with results varying from patient to patient. Our study shows a trend towards superior outcomes for children with acquired hearing loss and a shorter duration of hearing loss compared to congenitally deafened children who had a longer duration of SSD. This indicates an interactive influence of the age at onset, aetiology and duration of deafness upon the restoration of binaural integration and the overall benefits of sound stimulation to two ears after CI treatment. Continued longitudinal investigation of these children and further studies in larger groups may provide more guidance on the optimal timing of treatment for paediatric patients with acquired and congenital SSD.
Objective: To evaluate the benefits of bilateral electrical stimulation for hearing-impaired adult subjects using the Nucleus 24 cochlear implant in a multicenter study, and to compare and quantify performance on speech perception measures in quiet and in noise and localization ability for unilateral and bilateral cochlear implant use. Design: Repeated single subject measures were carried out for each subject, with each subject serving as their own control. Assessment of unilateral and bilateral listening conditions for performance on tests of speech comprehension and sound localization were performed. Speech comprehension measures were performed in quiet at 0 degree azimuth and in the presence of background noise simultaneously presented from the same speaker and spatially separated by 90 degrees, at S+45°N45°and at S−45°N+45°. Test materials included Freiburger monosyllabic words, Oldenburger sentences, and the Hochmair-Schulz-Moser sentences. Tests of localization were performed in the horizontal plane with 12 speaker locations 30 degrees apart using a shortened sentence stimulus from the Hochmair-Schulz-Moser sentences at two possible presentation levels of 55 and 70 dB sound pressure level for assessment of directionality. The binaural advantage provided by bilateral stimulation was calculated with respect to each ear separately, classified as either the better or poorer performing ear for each speech material in quiet and in noise test conditions. For localization of sound, the binaural advantage was compared with left and right ears separately. Paired comparisons for performance data in all conditions were carried out by considering measurements for each subject in different conditions as paired observations and applying the Student's t test to determine the statistical difference between the data sets. Setting: Tertiary referral centers with a cochlear implant program. Patients: Thirty-seven profoundly hearing-impaired adults were enrolled in the study, 22 simultaneously and 15 sequentially bilaterally implanted. All patients received the Nucleus 24 cochlear implant and used the Nucleus SPrint or ESPrit 3G speech processor, with the vast majority using the ACE speech coding strategy. Results: For spatially separated speech in noise conditions, an interaural performance advantage for the ear closest to the speech source (i.e., with a superior signal to noise ratio) compared with that for the ear closest to the noise source (i.e., with an inferior signal to noise ratio) is consistently demonstrated regardless of whether it is the better or poorer performing ear closest to the speech signal. This is referred to as a significant binaural head-shadow benefit, resulting in a mean improvement between −10 dB and −11.4 dB in the critical signal to noise ratio required for 50% speech comprehension for the Oldenburger sentences and a mean improvement in the maximum score of 42% to 55% for the ear closest to the speech signal over the ear farthest away for the Hochmair-Schulz-Moser sentences. Bilateral stimulation i...
The results support the hypothesis that the relationship between the radial distance of the electrode and the psychophysical measures are influenced by patterns of fibrous tissue growth and individual patient differences, such as etiology and neural survival. Impedance measures for the Nucleus 24 Contour electrode array were higher than the banded electrode array, but this is primarily due to the reduction in electrode surface area. The different outcomes in impedance over time suggest differences in the relative contributions of the components of impedance with the two arrays.
This report presents the first evidence of successful binaural rehabilitation with CI in a relatively large patient cohort and the advantages over (Bi)CROS and BCI in smaller subgroups, thus confirming the indication for CI treatment. Moreover, patients with long-term acquired deafness (>10 years) show a benefit from the CI comparable to that observed in patients with shorter-term deafness.
The impact of these findings may influence further developments of electrode arrays as well as surgical techniques for implantation.
Aims: The Nucleus CI532 cochlear implant incorporates a new precurved electrode array, i.e., the Slim Modiolar electrode (SME), which is designed to bring electrode contacts close to the medial wall of the cochlea while avoiding trauma due to scalar dislocation or contact with the lateral wall during insertion. The primary aim of this prospective study was to determine the final position of the electrode array in clinical cases as evaluated using flat-panel volume computed tomography. Methods: Forty-five adult candidates for unilateral cochlear implantation were recruited from 8 centers. Eleven surgeons attended a temporal bone workshop and received further training with a transparent plastic cochlear model just prior to the first surgery. Feedback on the surgical approach and use of the SME was collected via a questionnaire for each case. Computed tomography of the temporal bone was performed postoperatively using flat-panel digital volume tomography or cone beam systems. The primary measure was the final scalar position of the SME (completely in scala tympani or not). Secondly, medial-lateral position and insertion depth were evaluated. Results: Forty-four subjects received a CI532. The SME was located completely in scala tympani for all subjects. Pure round window (44% of the cases), extended round window (22%), and inferior and/or anterior cochleostomy (34%) approaches were successful across surgeons and cases. The SME was generally positioned close to the modiolus. Overinsertion of the array past the first marker tended to push the basal contacts towards the lateral wall and served only to increase the insertion depth of the first electrode contact without increasing the insertion depth of the most apical electrode. Complications were limited to tip fold-overs encountered in 2 subjects; both were attributed to surgical error, with both reimplanted successfully. Conclusions: The new Nucleus CI532 cochlear implant with SME achieved the design goal of producing little or no trauma as indicated by consistent scala tympani placement. Surgeons should be carefully trained to use the new deployment method such that tip fold-overs and over insertion may be avoided.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.