The EDOF IOL had distance acuity optical quality and halo effect similar to monofocal IOLs but worse near acuity compared to conventional bifocal IOLs. [J Refract Surg. 2018;34(4):236-243.].
PurposeTo compare the visual and refractive outcomes after laser-assisted in situ keratomileusis (LASIK) surgery for correction of myopia or myopic astigmatism using a six-dimensional Amaris excimer laser.MethodsIn this retrospective cohort study, we enrolled 47 eyes of 28 patients (age: 19–36 years) with myopia or myopic astigmatism. We used the Custom Ablation Manager protocol and performed ablations with the SCHWIND AMARIS system. LASIK flaps were cut with an iFS Advanced Femtosecond Laser. Mean static (SCC) and dynamic cyclotorsion (DCC) were evaluated. Visual and refractive outcomes were evaluated during 6 months’ follow-up. Corneal asphericity (Q-value) was analyzed at 4 months postoperatively.ResultsThe spherical equivalent (SE) reduction was statistically significant reduce 1 day after refractive surgery (P < 0.001), with no additional significant changes during follow-up (P = 0.854). SCC registration rates were 81% in the Aberration-Free mode (AF) and 90% in the Corneal Wavefront mode (CW). SCC measurements were within ± 5 degrees in 57% (AF) and 68% (CW) of eyes. Mean DCC was within ± 1 degree in 96% (AF) or 95% (CW) of cases. At 6 months, the uncorrected distance visual acuity was 20/25 or better in all eyes. At last follow-up, both steep and flat keratometry values had significantly flattened in both groups (P < 0.001). Corneal asphericity also increased significantly during the postoperative period for an 8-mm corneal diameter (P < 0.001).ConclusionsLASIK for myopia or myopic compound astigmatism correction using the six-dimensional AMARIS 750S excimer laser is safe, effective, and predictable. Postoperative corneal asphericity can be analyzed by linear regression to predict the changes in postoperative corneal asphericity with this approach.
Clear corneal incision (CCI) is a commonly used surgical approach in cataract surgery. In this prospective study, we evaluated the effect of CCI site on surgically induced astigmatism (SIA) and other postoperative astigmatic changes. CCIs were constructed based on the steep meridian of the total corneal refractive power in the 4.0-mm-zone (TCRP4.0), and patients were divided into four groups: temporal, superotemporal, superonasal, and superior according to the site of the incision. TCRP4.0 analysis demonstrated a statistically significant reduction of astigmatism with superior incisions (P < 0.001), and the combined mean polar values for SIA changed significantly in the temporal (Hotelling T2 = 1.977), superotemporal (Hotelling T2 = 0.544), superonsal (Hotelling T2 = 1.066), and superior incision groups (Hotelling T2 = 1.134) (all P < 0.001). The posterior axis alignment should be considered in cataract surgery with CCI, and the SIA is affected by axis rotation, and incision orientation.
Background: This study clinically evaluated the visual outcomes after refractive surgery for myopia using femtosecond laser-assisted in situ keratomileusis (femto-LASIK) and flap-off epipolis LASIK (epi-LASIK). Methods: In this retrospective case series study, 40 eyes of 27 patients were divided into two groups depending on the technique used for refractive surgery. Femto-LASIK and flap-off epi-LASIK flaps were created using femtosecond laser and Epi-K™ epikeratome, respectively. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, corneal asphericity, and corneal higher-order aberrations (HOAs) were assessed pre-and postoperatively. Results: The improvement in logarithm of the minimum angle of resolution (logMAR) UDVA after refractive surgery was statistically significant for both groups (P < 0.001 for all groups); it was significant better in UDVA in femto-LASIK than flap-off epi-LASIK, 0.03 ± 0.06 logMAR (femto-LASIK) and 0.54 ± 0.31 logMAR (flap-off epi-LASIK), at 1 day postoperatively; 0.02 ± 0.05 logMAR (femto-LASIK) and 0.14 ± 0.13 logMAR (flap-off epi-LASIK), at 1 week postoperatively (P < 0.001 and P = 0.019). With regard to the corneal HOAs, the increment in spherical aberration (Z 4,0) was greater in flap-off epi-LASIK than femto-LASIK: 0.626 ± 0.232 μm and 0.479 ± 0.139 μm in the front cornea; 0.556 ± 0.227 μm and 0.430 ± 0.137 μm in the total cornea (P = 0.016 and P = 0.017). However, the back corneal HOA changes did not have a significant effect on the total corneal HOA changes. Conclusion: Femto-LASIK yielded better early visual outcomes than did flap-off epi-LASIK, but there was no significant difference between the outcomes of the two procedures, 1 week postoperatively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.