The EDOF IOL had distance acuity optical quality and halo effect similar to monofocal IOLs but worse near acuity compared to conventional bifocal IOLs. [J Refract Surg. 2018;34(4):236-243.].
PurposeTo compare the visual and refractive outcomes after laser-assisted in situ keratomileusis (LASIK) surgery for correction of myopia or myopic astigmatism using a six-dimensional Amaris excimer laser.MethodsIn this retrospective cohort study, we enrolled 47 eyes of 28 patients (age: 19–36 years) with myopia or myopic astigmatism. We used the Custom Ablation Manager protocol and performed ablations with the SCHWIND AMARIS system. LASIK flaps were cut with an iFS Advanced Femtosecond Laser. Mean static (SCC) and dynamic cyclotorsion (DCC) were evaluated. Visual and refractive outcomes were evaluated during 6 months’ follow-up. Corneal asphericity (Q-value) was analyzed at 4 months postoperatively.ResultsThe spherical equivalent (SE) reduction was statistically significant reduce 1 day after refractive surgery (P < 0.001), with no additional significant changes during follow-up (P = 0.854). SCC registration rates were 81% in the Aberration-Free mode (AF) and 90% in the Corneal Wavefront mode (CW). SCC measurements were within ± 5 degrees in 57% (AF) and 68% (CW) of eyes. Mean DCC was within ± 1 degree in 96% (AF) or 95% (CW) of cases. At 6 months, the uncorrected distance visual acuity was 20/25 or better in all eyes. At last follow-up, both steep and flat keratometry values had significantly flattened in both groups (P < 0.001). Corneal asphericity also increased significantly during the postoperative period for an 8-mm corneal diameter (P < 0.001).ConclusionsLASIK for myopia or myopic compound astigmatism correction using the six-dimensional AMARIS 750S excimer laser is safe, effective, and predictable. Postoperative corneal asphericity can be analyzed by linear regression to predict the changes in postoperative corneal asphericity with this approach.
Clear corneal incision (CCI) is a commonly used surgical approach in cataract surgery. In this prospective study, we evaluated the effect of CCI site on surgically induced astigmatism (SIA) and other postoperative astigmatic changes. CCIs were constructed based on the steep meridian of the total corneal refractive power in the 4.0-mm-zone (TCRP4.0), and patients were divided into four groups: temporal, superotemporal, superonasal, and superior according to the site of the incision. TCRP4.0 analysis demonstrated a statistically significant reduction of astigmatism with superior incisions (P < 0.001), and the combined mean polar values for SIA changed significantly in the temporal (Hotelling T2 = 1.977), superotemporal (Hotelling T2 = 0.544), superonsal (Hotelling T2 = 1.066), and superior incision groups (Hotelling T2 = 1.134) (all P < 0.001). The posterior axis alignment should be considered in cataract surgery with CCI, and the SIA is affected by axis rotation, and incision orientation.
Background: This study clinically evaluated the visual outcomes after refractive surgery for myopia using femtosecond laser-assisted in situ keratomileusis (femto-LASIK) and flap-off epipolis LASIK (epi-LASIK). Methods: In this retrospective case series study, 40 eyes of 27 patients were divided into two groups depending on the technique used for refractive surgery. Femto-LASIK and flap-off epi-LASIK flaps were created using femtosecond laser and Epi-K™ epikeratome, respectively. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, corneal asphericity, and corneal higher-order aberrations (HOAs) were assessed pre-and postoperatively. Results: The improvement in logarithm of the minimum angle of resolution (logMAR) UDVA after refractive surgery was statistically significant for both groups (P < 0.001 for all groups); it was significant better in UDVA in femto-LASIK than flap-off epi-LASIK, 0.03 ± 0.06 logMAR (femto-LASIK) and 0.54 ± 0.31 logMAR (flap-off epi-LASIK), at 1 day postoperatively; 0.02 ± 0.05 logMAR (femto-LASIK) and 0.14 ± 0.13 logMAR (flap-off epi-LASIK), at 1 week postoperatively (P < 0.001 and P = 0.019). With regard to the corneal HOAs, the increment in spherical aberration (Z 4,0) was greater in flap-off epi-LASIK than femto-LASIK: 0.626 ± 0.232 μm and 0.479 ± 0.139 μm in the front cornea; 0.556 ± 0.227 μm and 0.430 ± 0.137 μm in the total cornea (P = 0.016 and P = 0.017). However, the back corneal HOA changes did not have a significant effect on the total corneal HOA changes. Conclusion: Femto-LASIK yielded better early visual outcomes than did flap-off epi-LASIK, but there was no significant difference between the outcomes of the two procedures, 1 week postoperatively.
Low-intensity extracorporeal shockwave therapy (Li-ESWT), as a microenergy therapy, has the effects of inhibiting oxidative stress, antiapoptosis, and tissue repair, which is increasingly applied to a variety of diseases. Our research aims to explore the protective effects of Li-ESWT in the aging rat model and its possible molecular mechanism through in vivo and in vitro experiments. In vitro, TM3 Leydig cells incubated with H2O2 were treated with Li-ESWT at 4 energy levels (0.01, 0.05, 0.1, and 0.2 mJ/mm2). In vivo, we employed an androgen-deficient rat model to simulate male aging and treated it with Li-ESWT at three different energy levels (0.01, 0.05, and 0.2 mJ/mm2). Li-ESWT increased the expression of vascular endothelial growth factor (VEGF) in TM3 cells, improved antioxidant capacity, and reduced apoptosis, with the effect being most significant at 0.05 mJ/mm2 energy level. In androgen-deficient rat model, LI-ESWT can improve sperm count, motility, and serum testosterone level, enhancing tissue antioxidant capacity and antiapoptotic ability, and the effect is most significant at 0.05 mJ/mm2 energy level. Therefore, Li-ESWT at an appropriate energy level can improve sperm count, motility, and serum testosterone levels in androgen-deficient rat models, reduce oxidative stress in the testis, and increase antioxidant capacity and antiapoptotic abilities. The mechanism of this condition might be related to the increased VEGF expression in Leydig cells by Li-ESWT.
In ad-hoc networks, a communication link between two mobile computers is not always bi-directional, i.e. unidirectional, since transmission power of mobile computers are not the same. Though some ad-hoc routing protocols, e.g. Extended DSR (Dynamic Source Routing), support routing with unidirectional links, multiple flooding RREP are used and communication overhead is high. This paper proposes a new adhoc routing protocol TPSR (Transmission Power based Routing Protocol) that supports unidirectional links in mobile ad-hoc networks. In our protocol, we use information of transmission power of each node to detect the existence of unidirectional links and to transmit single unicast RREP. Our protocol shows better performance in terms of the number of required messages than extended DSR in such environments as having unidirectional links.
A novel urolithiasis treatment in which chelating solution encapsulated in poly(lactic-co-glycolic acid; PLGA)-based microcapsules was delivered magnetically to specific urolithiasis sites and then subjected to ultrasound (US) to release the...
PurposeTo analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation.MethodsThis retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm).ResultsThe mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively).ConclusionThe corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.