ObjectivesEndonasal dacryocystorhinostomy (DCR) is a well-established treatment method in patients with nasolacrimal duct obstruction. However, there are a few reports about the overall management of failed endonasal DCR. We investigated the causes and management strategies of failed endonasal DCR.MethodsThis retrospective review included 61 patients (61 eyes) who had undergone revision surgery by the same surgeon after failed endonasal DCR between January 2008 and December 2012. The appropriate revision method was determined after analysis of the etiology of failure by the fluorescein dye disappearance test, nasal endoscopy, lacrimal irrigation, and probing. The criteria for success of the revision surgery were defined by the passage of fluid without resistance upon lacrimal irrigation and normalization of the tear meniscus height.ResultsThe mean duration between the primary endonasal DCR and revision surgery was 15.3 months. The average follow-up period after revision surgery was 12.2 months. The most common cause of endoscopic revision surgery was membranous obstruction. Endoscopic revision surgery was performed in 48 patients, while lacrimal silicone tube intubation under endoscopy was performed in 13 patients. The most common indication for lacrimal silicone tube intubation was functional epiphora. The overall success rate of the revision surgery was 89%.ConclusionThe most common cause of failed endonasal DCR was membranous obstruction. When patients with failed endonasal DCR presented at the clinic, it is important to identify the cause of the failure. Revision surgery could increase the final success rate of endonasal DCR.
With the recent emergence of flexible and wearable optoelectronic devices, the achievement of sufficient bendability and stretchability of transparent and conducting electrodes (TCEs) has become an important requirement. Although metal-mesh-based structures have been investigated for TCEs because of their excellent performances, the fabrication of mesh or grid structures with a submicron line width is still complex due to the requirements of laborious lithography and pattern transfer steps. Here, we introduce an extremely facile fabrication technique for metal patterns embedded in a flexible substrate based on submicron replication and an area-selective delamination (ASD) pattern. The high-yield, area-specific lift-off process is based on the principle of solvent-assisted delamination of deposited metal thin films and a mechanical triggering effect by soft wiping or ultrasonication. Our fabrication process is very simple, convenient, and cost-effective in that it does not require any lithography/etching steps or sophisticated facilities. Moreover, their outstanding optical and electrical properties (e.g., sheet resistances of 0.43 Ω sq at 94% transmittance), which are markedly superior to those of other flexible TCEs, are demonstrated. Furthermore, there is no significant change of resistance over 1000 repeated bending cycles, with a bending radius of 5 mm, and immersion in various solvents such as salt water and organic solvents. Finally, we demonstrate high-performance transparent heaters and flexible touch panels fabricated using the nanomesh electrode, confirming the long-range electrical conduction and reliability of the electrode.
A 43-year-old man developed decreased vision in the right eye that had persisted for seven years. Under slit lamp examination, corneal clouding was noted with normal endothelium and ocular structure. From the clinical evidence, we suspected that the patient had congenital hereditary stromal dystrophy (CHSD). He and his family underwent a genetic analysis. Penetrating keratoplasty was conducted, and the corneal button was investigated for histopathologic confirmation via both light and electron microscopy. The histopathologic results revealed mildly loosened stromal structures, which exhibited an almost normal arrangement and differed slightly from the previous findings of CHSD cases. With regard to the genetic aspects, the patient and his mother harbored a novel point mutation of the decorin gene. This genetic mutation is also distinct from previously described deletion mutations of the decorin gene. This case involved delayed penetration of mild clinical symptoms with the histological feature of a loosened fiber arrangement in the corneal stroma. We concluded that this condition was a mild form of CHSD. However, from another perspective, this case could be considered as "decorin gene-associated corneal dystrophy," which is distinct from CHSD. Further evaluation will be required for appropriate clinical, histopathologic and genetic approaches for such cases.
A 30-year-old male, who underwent previous pars plana vitrectomy and silicone oil tamponade due to endogenous endophthalmitis originated from Klebsiella liver abscess, was referred for evisceration. At 2 months after vitrectomy with silicon oil tamponade, conjunctival chemosis and ocular pain were aggravated. Diffuse eyelid swelling and large subconjunctival mass with lipid droplets were noted. On MRI examination, subconjunctival mass and intra- and extraconal orbital mass around superior rectus muscle were observed. Excision of subconjunctival and orbital mass was performed. Histopathologic examination showed multiple silicone oil vacuoles surrounded by foreign body giant cells and fibrosis, which confirmed silicone oil granuloma. In a patient with suspicious melting sclera in diseases such as endophthalmitis, large silicone oil granuloma may be complicated in a rapid fashion after intravitreal silicone oil tamponade due to silicone oil leakage.
PurposeTo investigate the causes of lower eyelid retraction and evaluate the outcomes of various surgical procedures.MethodsWe conducted a retrospective medical record review of patients who underwent lower eyelid retraction surgery performed by a single surgeon at Kim's Eye Hospital between 2006 and 2013. We investigated the causes of lower eyelid retraction, clinical history, characteristics, treatment, and surgical outcomes. Preoperative and postoperative margin reflex distance 2 and inferior scleral show were measured for each eyelid. Success was defined as a positive eyelid elevation and a decrease in inferior scleral show.ResultsA total of 19 lower eyelids were treated in 14 patients with lower eyelid retraction. For cosmetic reasons, surgical correction for congenital lower eyelid retraction was performed on seven eyelids (36.8%). Ten eyelids (52.6%) exhibited secondary lower eyelid retraction after surgery. One eyelid (5.3%) was affected by facial palsy and one eyelid (5.3%) exhibited exophthalmos of an unknown origin. We adopted a selective approach based on lower eyelid retraction severity. Spacer grafting via a subconjunctival approach was the most commonly performed surgical technique (13 eyelids, 68.4%). The lateral tarsal strip procedure was used to horizontally tighten three eyelids (15.8%). At the time of the procedure, one of these eyelids (5.3%) also received an adjuvant suborbicularis oculi fat lift. Autogenous dermis fat grafting was performed on two lower eyelids (10.5%), whose retraction was caused by fat and soft tissue loss. Cosmetic outcomes were satisfactory in all cases.ConclusionsTo achieve satisfactory surgical outcomes, surgeons should adopt an approach based on the severity of lower eyelid retraction. Mild lower eyelid retraction can be corrected without grafts. When retraction is severe and exceeds 2 mm, spacer grafts that push the lower eyelid margin upwards and support it from below are required.
The extensive upper and lower eyelid defects with large vertical component can be successfully repaired using ADA as a tarsal substitute. The results of our study with long-term follow-up indicate excellent functional and cosmetic outcomes with minimal morbidity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.