OBJECTIVE
To study the circadian rhythm of melatonin in children with enuresis.
PATIENTS AND METHODS
Twenty‐five children, divided into two groups (enuretic patients and controls) were assessed; salivary samples were collected to measure melatonin by radioimmunoassay using commercial kits. Friedman two‐way anova and Wilcoxon tests were used to assess the circadian rhythm of melatonin, and anova with between‐patient factors and Mann‐Whitney tests to compare melatonin values and groups.
RESULTS
Both groups had statistically significant differences in melatonin concentration during the 24‐h period (both P < 0.001), with a circadian rhythm; the highest values were always at ≈ 04.00 hours. There were no significant differences overall in melatonin values between cases and controls, but patients had lower peak values than controls at 04.00 hours, and higher melatonin levels at 24.00 hours, but with no significant differences.
CONCLUSION
There was some evidence for minor disturbances in the circadian rhythm of melatonin as a cause of enuresis, but the rhythm was not grossly disrupted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.